• 제목/요약/키워드: matrix assisted laser desorption/ ionization (MALDI)

검색결과 186건 처리시간 0.021초

Application of Thermal Vapor Deposition Method for MALDI-MS : Molecular Weight Determination of Insoluble Sorbitol Derivatives (열증착 시료 제작법이 적용된 MALDI 질량분석법에 의한 불용성 Sorbitol 유도체의 분자량 결정)

  • 신철민;남해선;김성호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제4권3호
    • /
    • pp.260-262
    • /
    • 2003
  • A thermal vapor deposition method for crystallization of insoluble analytes with matrix is established as a new sample preparation method for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). A mixture of mono, bis and tris(p-ethyl benzylidene) sorbitols was incorporated into microcrystals of ferulic acid, which was confirmed by confocal micrographs. Molecular masses of sorbitol derivatives were determined in this way by MALDI-MS without thermal decomposition.

  • PDF

Application of Thermal Vapor Deposition Method for MALDI-MS : Molecular Weight Determination of Insoluble Sorbitol Derivatives (열증착 시료 제작법이 적용된 MALDI 질량분석법 에 의한 불용성 Sorbitol 유도체의 분자량 결정)

  • 신철민;남해선;김성호
    • Proceedings of the KAIS Fall Conference
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.311-313
    • /
    • 2003
  • A thermal vapor deposition method for crystallization of insoluble analysis with matrix is established as a new sample preparation method for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). A mixture of mono, bis and tris(p-ethyl benzylidene) sorbitols was incorporated into microcrystals of ferulic acid, which was confirmed by confocal micrographs. Molecular masses of sorbitol derivatives were determined in this way by MALDI-MS without thermal decomposition.

  • PDF

Development of a Rapid and Accurate Identification Method for Citrobacter Species Isolated from Pork Products Using a Matrix-Assisted Laser-Desorption Ionization Time-of-Flight Mass Spectrometry (MALDITOF MS)

  • Kwak, Hye-Lim;Han, Sun-Kyung;Park, Sunghoon;Park, Si Hong;Shim, Jae-Yong;Oh, Mihwa;Ricke, Steven C.;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권9호
    • /
    • pp.1537-1541
    • /
    • 2015
  • Previous detection methods for Citrobacter are considered time consuming and laborious. In this study, we have developed a rapid and accurate detection method for Citrobacter species in pork products, using matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS). A total of 35 Citrobacter strains were isolated from 30 pork products and identified by both MALDI-TOF MS and 16S rRNA gene sequencing approaches. All isolates were identified to the species level by the MALDI-TOF MS, while 16S rRNA gene sequencing results could not discriminate them clearly. These results confirmed that MALDITOF MS is a more accurate and rapid detection method for the identification of Citrobacter species.

Identification of Salmonella spp. from porcine salmonellosis by matrix-assisted laser desorption ionization-time of flight mass spectrometry

  • Yang, Hyoung-Seok;Kim, Jae-Hoon
    • Korean Journal of Veterinary Service
    • /
    • 제41권2호
    • /
    • pp.105-110
    • /
    • 2018
  • A total of 41 Salmonella (S.) strains were isolated from pigs suffered with severe watery diarrhea and were tried to identify by both matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and polymerase chain reaction (PCR) analysis. Fibrinous exudate and ulceration in the large intestine were prevalent in gross observation, and variable degrees of enteritis were observed in the histology of large intestines. Subsequent polymerase chain reaction (PCR) analyses demonstrated that 41 strains were identified as S. Typhimurium (39 strains), though 2 stains were failed to identify. Further identification was performed using both direct smear and protein extraction method by MALDI-TOF MS analyses. In terms of extraction methods, 100% (41/41) of isolates were identified to species level of S. spp. Whereas only 43.9% (18/41) were identified to species level using the direct method. These results thus suggest that rapid and accurate diagnosis of porcine salmonellosis can be guaranteed by MALDI-TOF MS combined with protein extraction method.

Characterization of Poly(ethylene oxide)-b-Poly(L-lactide) Block Copolymer by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

  • Jeongmin Hong;Donghyun Cho;Taihyun Chang;Shim, Woo-Sun;Lee, Doo-Sung
    • Macromolecular Research
    • /
    • 제11권5호
    • /
    • pp.341-346
    • /
    • 2003
  • A poly(ethylene oxide)-b-poly(L-lactide) diblock copolymer (PEO-b-PLLA) is characterized by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and a block length distribution map is constructed. Although the MALDI- TOF mass spectrum of PEO-b-PLLA is very complicated, most of the polymer species were identified by isolating the overlapped isotope patterns and by fitting the overlapped peaks to the Schulz-Zimm distribution function. Reconstructed MALDI-TOF MS spectrum was nearly identical to the measured spectrum and this method shows its potential to be developed as an easy and fast analysis method of low molecular weight block copolymers.

Optimization in Detecting Multiply-charged Protein Ions using MALDI TOF-MS

  • Lee, Jihyeon;Hong, Jangmi;Kim, Taehee;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • 제4권1호
    • /
    • pp.21-23
    • /
    • 2013
  • The effects of trifluoroacetic acid (TFA) were evaluated on the generation of multiply charged ions of cytochrome c in a 2-nitrophloroglucinol (2-NPG) matrix in high-vacuum, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The presence of 1% TFA in the 2-NPG matrix solution was more effective in generating multiply charged protein ions than matrix solutions containing 0.1% or 0% TFA. Regarding the matrix itself, with 1% TFA, 2-NPG was significantly more effective in generating multiply charged ions than 2,5-dihydroxybenzoic acid (2,5-DHB). The maximum charge state of cytochrome c was +8 when using a 2-NPG matrix containing 1% TFA.

Matrix-Assisted Variable Wavelength Laser Desorption Ionization of Peptides; Influence of the Matrix Absorption Coefficient on Expansion Cooling

  • Ahn, Sung-Hee;Bae, Yong-Jin;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권9호
    • /
    • pp.2955-2960
    • /
    • 2012
  • Product ion yields in the in- and post-source decays of three peptide ions, $[Y_5X+H]^+$ (X = Y (tyrosine), K (lysine), and R (arginine)), generated by matrix-assisted laser desorption ionization (MALDI) were measured at six wavelengths, 307, 317, 327, 337, 347, and 357 nm, using ${\alpha}$-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as the matrices. The temperatures of the early and late plumes generated by MALDI were estimated via kinetic analysis of the product ion yield data. For both matrices, the temperature drop (${\Delta}T$), i.e. the difference in the temperature between the early and late plumes, displayed negative correlation with the absorption coefficient. This was in agreement with the previous reasoning that deeper laser penetration and larger amount of material ablation arising from smaller absorption coefficient would result in larger extent of expansion cooling. The results support the postulation of the expansion cooling occurring in the plume presented previously.

Observation of Peptide-Ion Generation by Laser-Induced Surface Heating from Tungsten Silicide Surfaces

  • Kim, Shin-Hye;Park, Sun-Hwa;Song, Jae-Yong;Han, Sang-Yun
    • Mass Spectrometry Letters
    • /
    • 제3권1호
    • /
    • pp.18-20
    • /
    • 2012
  • We report observation of laser desorption/ionization (LDI) of peptides from flat surfaces of tungsten silicide ($WSi_2$). In contrast to MALDI (matrix-assisted laser desorption/ionization) and SALDI (surface-assisted laser desorption/ionization) mass spectrometry, this study did not utilize any matrices and surface nanostructures. In this work, LDI on $WSi_2$ surfaces is demonstrated to cover a mass range up to 1,600 Da (somatostatin; monoisotopic mass = 1637.9 Da). In addition, it exhibited a high sensitivity, which could detect peptides, which could detect peptides of low femtomole levels (20 fmol for angiotensin II). The observed LDI process was discussed to be largely thermal, more specifically, due to laser-induced surface heating that is most likely promoted by the low thermal diffusivity (${\kappa}$) of $WSi_2$ substrate.

Molecular Weight Determination of Polymers by Matrix Assisted Laser Desorption Ionization in Mass Spectrometry

  • Kim, Jin Sung;Yoo, Jong Shin
    • Analytical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.465-468
    • /
    • 1995
  • Matrix assisted laser desorption ionization in mass spectrometry is a fast and accurate method to determine the molecular weight of natural and synthetic polymers. Unknown peptides such as elastase inhibitor and $\small{D}$-hydantoinase were analyzed using sinapinic acid as matrix and their molecular weights were compared with the results from protein sequencer and gel filtration chomatography, respectively. Synthetic polymers such as polyethyleneglycol, polypropyleneglycol, polydimethylsiloxane, and polystyrene were analyzed using matrices such as 2,5-dihydroxybenzoic acid, 4-hdroxyazobenzenecarboxylic acid, and 2-nitrophenyl octyl ether. Average molecular weights of polystyrene were compared with molecular weights by gel permeation chromatography.

  • PDF

Discrimination of Bacillus anthracis Spores by Direct in-situ Analysis of Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry

  • Jeong, Young-Su;Lee, Jonghee;Kim, Seong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2635-2639
    • /
    • 2013
  • The rapid and accurate identification of biological agents is a critical step in the case of bio-terror and biological warfare attacks. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been widely used for the identification of microorganisms. In this study, we describe a method for the rapid and accurate discrimination of Bacillus anthracis spores using MALDI-TOF MS. Our direct in-situ analysis of MALDI-TOF MS does not involve subsequent high-resolution mass analyses and sample preparation steps. This method allowed the detection of species-specific biomarkers from each Bacillus spores. Especially, B. anthracis spores had specific biomarker peaks at 2503, 3089, 3376, 6684, 6698, 6753, and 6840 m/z. Cluster and PCA analyses of the mass spectra of Bacillus spores revealed distinctively separated clusters and within-groups similarity. Therefore, we believe that this method is effective in the real-time identification of biological warfare agents such as B. anthracis as well as other microorganisms in the field.