• 제목/요약/키워드: mass estimation model

검색결과 271건 처리시간 0.027초

Hydraulic conductivity estimation by considering the existence of piles: A case study

  • Yuan, Yao;Xu, Ye-Shuang;Shen, Jack S.;Wang, Bruce Zhi-Feng
    • Geomechanics and Engineering
    • /
    • 제14권5호
    • /
    • pp.467-477
    • /
    • 2018
  • Estimation of hydraulic parameters is a critical step during design of foundation dewatering works. When many piles are installed in an aquifer, estimation of the hydraulic conductivity should consider the blocking of groundwater seepage by the piles. Based on field observations during a dewatering project in Shanghai, hydraulic conductivities are back-calculated using a numerical model considering the actual position of each pile. However, it is difficult to apply the aforementioned model directly in field due to requirement to input each pile geometry into the model. To develop a simple numerical model and find the optimal hydraulic conductivity, three scenarios are examined, in which the soil mass containing the piles is considered to be a uniform porous media. In these three scenarios, different sub-regions with different hydraulic conductivities, based on either automatic inverted calculation, or on effective medium theory (EMT), are established. The results indicate that the error, in the case which determines the hydraulic conductivity based on EMT, is less than that determined in the automatic inversion case. With the application of EMT, only the hydraulic conductivity of the soil outside the pit should be inverted. The soil inside the pit with its piles is divided into sub-regions with different hydraulic conductivities, and the hydraulic conductivity is calculated according to the volume ratio of the piles. Thus, the use of EMT in numerical modelling makes it easier to consider the effect of piles installed in an aquifer.

제품구성모델을 이용한 쌍동형 레저보트 건조공수 추정 연구 (Study of Shipbuilding Cost Estimation for Catamaran-type Leisure Boats Using Product Configuration Model)

  • 오대균;오우준;이동건
    • 대한기계학회논문집A
    • /
    • 제38권8호
    • /
    • pp.911-916
    • /
    • 2014
  • 레저보트산업은 미래형 고부가가치 산업으로 최근 국내에서는 한국형 고속레저낚시보트에 대한 연구가 수행되었다. 본 논문에서는 고속레저낚시보트의 대량생산을 위한 기초연구로서 제품구성모델 기반의 건조공수 추정 연구를 수행하였다. 이를 위해 레저보트의 건조공정을 분석하고 범용 작업분류체계를 적용하였으며, 업체 설문조사를 통해 계층분석법 기반의 레저보트 건조공수 비례계수를 도출하였다. 또한 실적선의 공수를 기반으로 비례계수를 이용한 개발선 후보들의 정량적인 공수추정을 수행하였으며, 그 결과 실적선 공수 대비 17% 감소된 쌍동형 개발선을 최종 선정할 수 있었다. 이는 개발된 레저보트의 설계가 실제 건조단계에서 가격경쟁력을 갖출 수 있는 양산가능수준의 제품임을 의미한다.

가설-검증 문제를 이용한 혼합 프라이어를 가지는 베이지안 영상 잡음 제거 (Bayesian Image Denoising with Mixed Prior Using Hypothesis-Testing Problem)

  • 엄일규;김유신
    • 대한전자공학회논문지SP
    • /
    • 제43권3호
    • /
    • pp.34-42
    • /
    • 2006
  • 일반적으로 웨이블릿 계수는 적은 수의 계수에 거의 대부분의 정보가 저장되어 있다. 이러한 웨이블릿 계수의 성긴 특성은 가우스 확률밀도 함수와 영점에서의 점 질량(point mass) 함수의 혼합으로 모델링될 수 있으며, 이 프라이어(prior) 모델에 대한 베이지안 추정법으로 잡음 제거를 수행한다. 본 논문에서는 가설-검증 기법을 이용하여 잡음 제거를 위한 파라미터를 추정하는 방법을 제안한다. 가설-검증은 관찰된 웨이블릿 계수의 분산에 적용되며, $X^2$-검증을 사용한다. 모의실험 결과를 통하여 본 논문의 방법이 직교 웨이블릿 변환을 사용한 최신의 잡음 제거 방법보다 대략 0.3dB 정도 우수한 PSNR(peak signal-to-noise ratio) 성능을 나타낸다.

Mass-balance 및 경제성 분석에 의한 빗물저류시설 적정 규모 산정 (Estimation of Optimum Capacity for Rainwater Storage Facilities based on Mass Balance and Economic Analysis)

  • 김영민;이상호;이정훈;김이호
    • 상하수도학회지
    • /
    • 제22권2호
    • /
    • pp.233-238
    • /
    • 2008
  • Recently, rainwater harvesting facilities have increasingly constructed mainly in elementary schools and government buildings. Nevertheless, few methods are available for efficient planning and design of rainwater harvesting facilities by considering the weather conditions and purpose of rainwater management in each site, which may lead to a construction of uneconomic facilities. The current method estimates the size of rainwater storage tank by multiplying the size of building or plottage with a certain ratio and has many limitations. In this study, we first developed a method for planning and design of rainwater storage facilities using $Rainstock^{TM}$ model, which is based on mass balance, and economic analysis. Then, the model was applied for the design of a rainwater harvesting facility in a building with the catchment area of $1,000m^2$. The model calculation indicated that the economic feasibility of rainwater harvesting depends on not only the size of storage tank but also the water usage rate. When the water usage rate is $1m^3/day$, the rainwater harvesting facility is not cost-effective regardless of the size of the storage tank. With increasing the water usage rate, the economical efficiency of the facility was improved for a specific size of the storage tank. Based on the model calculation, the optimum tank sizes for $5m^3/day$ and $10m^3/day$ of water usage rates were $24m^3$ and $57m^3$, respectively. It is expected that the model is useful for optimization of rainwater storage facilities in planning and designing steps.

축소모형실험에 의한 불연속면 암반에서의 병설터널 적용성 평가 (Evaluation on Tunnel in Uncontinuous Rock Mass by Small-Scale Model Tests)

  • 김홍택;유찬호;황정순;윤현돈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.181-188
    • /
    • 2008
  • In this study, estimation of behavioral characteristics between twin tunnels was performed through the series of laboratory experiment on the small scale tunnel model. In the model test, the experimental parameters were geological conditions, center to center distance between twin tunnels, application of discontinuous inclination. To estimated behavior of pillar and load-displacement relationship by model tests and numerical analyses.

  • PDF

Statistical analysis of KNHANES data with measurement error models

  • Hwang, Jinseub
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권3호
    • /
    • pp.773-779
    • /
    • 2015
  • We study a statistical analysis about the fifth wave data of the Korea National Health and Nutrition Examination Survey based on linear regression models with measurement errors. The data is obtained from a national population-based complex survey. To demonstrate the availability of measurement error models, two results between the general linear regression model and measurement error model are compared based on the model selection criteria which are Akaike information criterion and Bayesian information criterion. For our study, we use the simulation extrapolation algorithm for measurement error model and the jackknife method for the estimation of standard errors.

밀폐박스 상태의 가상 라우드스피커 매개변수 규명법 및 개선된 밀폐박스 모델링 (Parameters Estimation for Pseudo Loudspeaker attached to Closed-Box and Enhanced Closed-Box Modeling)

  • 박석태
    • 한국소음진동공학회논문집
    • /
    • 제17권10호
    • /
    • pp.983-992
    • /
    • 2007
  • It was proposed to identify Thiele Small Parameters for loudspeaker attached to closed-box using known dynamic mass of moving parts. Also, enhanced PSPICE circuit model for closed-box loudspeaker system was proposed to more accurately simulate real closed-box loudspeaker system. Frequency dependent parameters were used to model voice coil inductor. Acoustic pressure response curves and electrical impedance curves were simulated and investigated by PSPICE circuit model according to compensation filter's parameters. Finally, proposed method is expected to be utilized for identification of pseudo Thiele Small parameters of microspeaker.

A pooled Bayes test of independence using restricted pooling model for contingency tables from small areas

  • Jo, Aejeong;Kim, Dal Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제29권5호
    • /
    • pp.547-559
    • /
    • 2022
  • For a chi-squared test, which is a statistical method used to test the independence of a contingency table of two factors, the expected frequency of each cell must be greater than 5. The percentage of cells with an expected frequency below 5 must be less than 20% of all cells. However, there are many cases in which the regional expected frequency is below 5 in general small area studies. Even in large-scale surveys, it is difficult to forecast the expected frequency to be greater than 5 when there is small area estimation with subgroup analysis. Another statistical method to test independence is to use the Bayes factor, but since there is a high ratio of data dependency due to the nature of the Bayesian approach, the low expected frequency tends to decrease the precision of the test results. To overcome these limitations, we will borrow information from areas with similar characteristics and pool the data statistically to propose a pooled Bayes test of independence in target areas. Jo et al. (2021) suggested hierarchical Bayesian pooling models for small area estimation of categorical data, and we will introduce the pooled Bayes factors calculated by expanding their restricted pooling model. We applied the pooled Bayes factors using bone mineral density and body mass index data from the Third National Health and Nutrition Examination Survey conducted in the United States and compared them with chi-squared tests often used in tests of independence.

신뢰성 기준을 적용한 용수공급능력의 해석 - 낙동강유역을 중심으로 - (The Analysis of Water Supply Capacity using Reliability Criteria - for the Nakdong River Basin -)

  • 차상화;지홍기;이순탁
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1227-1233
    • /
    • 2002
  • In general, the evaluation of water supply capacity is important factor to establish various establishment of water resource supply plan include water resource security and determination of dam's mass. But former researchs about estimation of water supply capacity were lack in continunity of evaluation basis, and didn't excute analysis on reliability criteria also. In this study, Nakdong river was selected for study basin, and then water supply capacity was analyzed by HEC-5 model using identical reliability criteria.

과열기와 과열저감기에 대한 모델링 및 파라미터 추정 (Modeling and Parameter Estimation of Superheater and Desuperheater)

  • 이순영;신휘범
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2012-2015
    • /
    • 2010
  • In this paper, the mathematical models of the superheater and the desuperheater are derived based on the fundamental laws of physics, mass and energy balance. The parameters of the models are developed for the 500[MW] thermal power plant using the actual data. The simulated model outputs are well matched with the actual ones. It is expected that the proposed models are useful for the temperature controller design of the thermal power plant.