• Title/Summary/Keyword: main control room

Search Result 211, Processing Time 0.031 seconds

DISTRIBUTED HMI SYSTEM FOR MANAGING ALL SPAN OF PLANT CONTROL AND MAINTENANCE

  • Yoshikawa, Hidekazu
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.237-246
    • /
    • 2009
  • Digitalization of not only non-safety but also safety-grade I &C systems with full computerized Main Control Room (MCR) is the recent trend of I&C systems of nuclear power plants (NPP) around the world, while plant maintenance has been shifting from traditional time based maintenance to condition based maintenance. In order to cope with the new trend of operation and maintenance in NPP, a concept of online distributed diagnostic system for both plant operation and maintenance has been proposed in order to further improve both the plant efficiency and the work environment of plant operation staff members by organizational learning. In this respect, the research subjects of human machine interface (HMI) for the online distributed diagnostic system are also discussed for supporting the plant personnel at both MCR and local working places in the plant by the application of advanced ICT (Information and Communication Technologies).

An Study of Pressure Variations in Smoke Control on Protected Escape Routes Using Pressurization (급기가압 제연 시 전실 내 압력변화에 관한 연구)

  • Kim, Hong-Sik;Oh, Dae-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.247-250
    • /
    • 2008
  • Pressurization is a method of ensuring that protected escape routes(staircases and lobbies) are kept free of smoke for shelterers and fire fighters by raising the air pressure in these spaces above that in the main part of the building. In this study, to estimate a pressurization, the characteristics of pressure difference in a room, a lobby, an air supply shaft at several building elements are investigated with a window, the (a fire) door and a air supply damper so that information about the importance of these experimental parameters can be obtained.

  • PDF

A study on the moving picture transmission method between the accident sites and control center(II) (사고현장과 사령실간 화상전송기술에 관한 연구(II))

  • Chang Seok-Gahk;Cho Bong-Kwan
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.653-658
    • /
    • 2003
  • This study is represented a method to give connect to optical cable from accident site and reviewed the method to transmission a moving image to control centre by real time, following the study of image transmission method in copper cable section where is a main line of railroad communication. Concept of network is studied to use cable and equipment effectively, and it's also reviewed technology of digital image transmission system and image evaluation methods, in spite of the pixel of camera and monitor resolution determine quality of image when moving image transferring by point to point. In addition, this study is reviewed checks and considerations of image transmission equipment (codec) with various transmission methods in room test, and then examined and analyzed wire/wireless combined transmission methods at wayside.

  • PDF

A REVIEW ON DEVELOPING INDUSTRIAL STANDARDS TO INTRODUCE DIGITAL COMPUTER APPLICATION FOR NUCLEAR I&C AND HMIT IN JAPAN

  • Yoshikawa, Hidekazu
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.165-178
    • /
    • 2013
  • A comprehensive review on the technical standards about human factors (HF) design and software reliability maintenance for digital instrumentation and control (I&C) and human-machine interface technology (HMIT) in Japanese light water reactor nuclear power plants (NPPs) was given in this paper mainly by introducing the relevant activities at the Japan Electric Association to set up many industrial standards within the traditional framework of nuclear safety regulation in Japan. In Japan, the Fukushima Daiichi accident that occurred on March 11, 2011 has great impact on nuclear regulation and nuclear industries where concerns by the general public about safety have heightened significantly. However for the part of HF design and software reliability maintenance of digital I&C and HMIT for NPP, the author believes that the past practice of Japanese activities with the related technical standards can be successfully inherited in the future, by reinforcing the technical preparedness for the prevention and mitigation against any types of severe accident occurrence.

Research on Cognition of Infection Control by Dental Hygienics Student's in some Areas (일부 지역 치위생학과 학생들의 감염방지에 관한 인식 조사)

  • Moon, Seon-Jeong;Ku, In-Young
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.313-320
    • /
    • 2012
  • A dental treatment room is always exposed to diverse kinds of pathogenic bacteria, and may be a mediating place of cross-infection given being contaminated the interior of a room through several routes in the form of patient's secretion and aerosol. The main agent of preventing cross-infection is a dental hygienist in the dental treatment and the dental treatment room where are scattered about a risk of cross-infection. A dental hygienist needs to have right recognition on infection control before being active as a clinical expert. This infection-control recognition level is influenced from the clinical practice. Accordingly, to survey recognition of infection control, a self-administered questionnaire research was conducted targeting 314 students who are fixed the clinical practice as regular subject in the junior course out of curriculum for the Department of Dental Hygiene at some of 4-year universities. Data collection was performed from December 9, 2011 to February 22, 2012. Except 11 copies of questionnaire with insincere response among the collected materials, 303 copies were finally analyzed by using SPSS WIN 20.0. The following conclusions were obtained. In the infection disease section, both on and off campus showed 4.89 points from 'the importance of recognizing the infections prevention', 4.65 points from 'recognizing the compulsory preventative injection for hepatitis type B', 4.77 points from 'recognizing the necessity of the preventative injection for hepatitis type B', 4.71 points from 'whether practice the prevention in reality or not', and 4.76 points from 'the educational helps to the prevention'. In other words, the section recorded the highest and meaningful points. It is considered to be needed the development in systematic and diverse infection-control educational programs and the differentiated education depending on school year for dental hygiene students.

Optimized Flooding Analysis Method for Compartment for Nuclear Power Plant (원전 격실에 대한 최적 침수분석 방법)

  • Song, Dong-Soo;Kim, Sang-Yeol
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper a realistic bounding method for flooding analysis following rupture of large size of thanks and piping is defined. Mass and energy release during main feedwater line break accident is analyzed with RETRAN code. It is modeled that the main feed water control valve is closed in 5.0 seconds after reactor trip. In result of the analysis, largest mass and energy is discharged at 70% reactor power. The flood sources for main feedwater room are calculated when piping failure occurs in the high energy line and medium energy line. Based on the result of flood level (1.43m), it is investigated that all of the safety-related environmental qualification equipments are well located above the flood level.

Development of Human Performance Measures for Human Factors Validation in Advanced Nuclear Power Plants (신형원전 주제어실 인적요소 검증을 위한 인적수행도 평가척도 개발)

  • Ha, Jun-Su;Seong, Poong-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.85-96
    • /
    • 2006
  • Main control room(MCR) man-machine interface(MMI) design of advanced nuclear power plants(NPPs) such as APR(advanced power reactor)-1400 can be validated through performance-based tests to determine whether it acceptably supports safe operation of the plant. In this work, plant performance, personnel task, situation awareness, workload, teamwork, and anthropometric/physiological factor are considered as factors for the human performance evaluation. For development of measures in each of the factors, techniques generally used in various industries and empirically proven to be useful are adopted as main measures and some helpful techniques are developed in order to complement the main measures. Also the development of the measures is addressed based on the theoretical background. Finally we discuss the way in which the measures can be effectively integrated and then HUPESS(HUman Performance Evaluation Support System) which is in development based on the integrated way is briefly introduced.

Operating Characteristics of a Main Oxidizer Shut-off Valve According to Operating Times (작동 횟수에 따른 연소기 산화제 개폐밸브 작동 특성)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-83
    • /
    • 2020
  • The operating characteristics of a main oxidizer shut-off valve have been examined by life-cycle tests in which the valve operates as many times as is required at room and cryogenic temperatures. It is shown that there is no significant change of the operating characteristics in the course of the life-cycle tests. The critical pressures and principal forces, which represent the operating characteristics, differ at each operating time by less than about 3%. These qualified operating characteristics of the valve are expected to play an indispensible role in the stable startup and shutdown of a liquid rocket engine.

The Overall Measurement System Development for On-line Test of Super-speed Maglev Train (초고속 자기부상철도 시운전시험을 위한 종합계측시스템 개발)

  • Han, Young-Jae;Lee, Jin-Ho;Jo, Jung-Min;Kim, Lee-Hyung;Lee, Chang-Young;Ha, Chang-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.902-910
    • /
    • 2016
  • This paper presents the overall measurement system for on-line test of super-speed maglev train. The super-speed maglev train is composed of vehicle, propulsion, power, and so on. In order to evaluate and diagnose for sub-system, we made overall measurement system. Just like the other measurement system, it is designed to distributed type. The hardware is consist of SCXI, PXI, Terminal, UPS, and so forth. It is installed on a train, control room, power room and track to collect lots of signals. The software controls hardware system, monitors main data such as inverter current, converter voltage. Using the measurement system, we evaluated a lot of performances for vehicle, track, and so forth. Through the developed system have improved reliability and safety for super-speed maglev train.

Estimation of the Noise Caused by the System Air Conditioner and its Improvement (시스템 에어컨에 의한 실내 소음 평가 및 개선 설계)

  • Lee, Jea-Won;Joo, Jae-Man;Oh, Sang-Kyong;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF