• Title/Summary/Keyword: magnification

Search Result 689, Processing Time 0.023 seconds

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF

A Study on Differentiation and Improvement in Arbitration Systems in Construction Disputes (건설분쟁 중재제도의 차별화 및 개선방안에 관한 연구)

  • Lee, Sun-Jae
    • Journal of Arbitration Studies
    • /
    • v.29 no.2
    • /
    • pp.239-282
    • /
    • 2019
  • The importance of ADR(Alternative Dispute Resolution), which has the advantage of expertise, speed and neutrality due to the increase of arbitration cases due to domestic and foreign construction disputes, has emerged. Therefore, in order for the nation's arbitration system and the arbitration Organization to jump into the ranks of advanced international mediators, it is necessary to research the characteristics and advantages of these arbitration Organization through a study of prior domestic and foreign research and operation of international arbitration Organization. As a problem, First, education for the efficient promotion of arbitrators (compulsory education, maintenance education, specialized education, seminars, etc.). second, The effectiveness of arbitration in resolving construction disputes (hearing methods, composition of the tribunal, and speed). third, The issue of flexibility and diversity of arbitration solutions (the real problem of methodologies such as mediation and arbitration) needs to be drawn on the Arbitration laws and practical problems, such as laws, rules and guidelines. Therefore, Identify the problems presented in the preceding literature and diagnosis of the defects and problems of the KCAB by drawing features and benefits from the arbitration system operated by the international arbitration Institution. As an improvement, the results of an empirical analysis are derived for "arbitrator" simultaneously through a recognition survey. As a method of improvement, First, as an optimal combination of arbitration hearing and judgment in the settlement of construction disputes,(to improve speed). (1) A plan to improve the composition of the audit department according to the complexity, specificity, and magnification of the arbitration cases - (1)Methods to cope with the increased role of the non-lawyer(Specialist, technical expert). (2)Securing technical mediators for each specialized expert according to the large and special corporation arbitration cases. (2) Improving the method of writing by area of the arbitration guidelines, second, Introduction of the intensive hearing system for psychological efficiency and the institutional improvement plan (1) Problems of optimizing the arbitration decision hearing procedure and resolution of arbitration, and (2) Problems of the management of technical arbitrators of arbitration tribunals. (1)A plan to expand hearing work of technical arbitrator(Review on the introduction of the Assistant System as a member of the arbitration tribunals). (2)Improved use of alternative appraisers by tribunals(cost analysis and utilization of the specialized institution for calculating construction costs), Direct management of technical arbitrators : A Study on the Improvement of the Assessment Reliability of the Appraisal and the Appraisal Period. third, Improvement of expert committee system and new method, (1) Creating a non-executive technical committee : Special technology affairs, etc.(Major, supports pre-qualification of special events and coordinating work between parties). (2) Expanding the standing committee.(Added expert technicians : important, special, large affairs / pre-consultations, pre-coordination and mediation-arbitration). This has been shown to be an improvement. In addition, institutional differentiation to enhance the flexibility and diversity of arbitration. In addition, as an institutional differentiation to enhance the flexibility and diversity of arbitration, First, The options for "Med-Arb", "Arb-Med" and "Arb-Med-Arb" are selected. second, By revising the Agreement Act [Article 28, 2 (Agreement on Dispute Resolution)], which is to be amended by the National Parties, the revision of the arbitration settlement clause under the Act, to expand the method to resolve arbitration. third, 2017.6.28. Measures to strengthen the status role and activities of expert technical arbitrators under enforcement, such as the Act on Promotion of Interestments Industry and the Information of Enforcement Decree. Fourth, a measure to increase the role of expert technical Arbitrators by enacting laws on the promotion of the arbitration industry is needed. Especially, the establishment of the Act on Promotion of Intermediation Industry should be established as an international arbitration agency for the arbitration system. Therefore, it proposes a study of improvement and differentiation measures in the details and a policy, legal and institutional improvement and legislation.

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

The Effect of Seminal Plasma on Chilling and Freezing of Canine Spermatozoa (개 정액의 정장이 개정자의 냉각과 동결에 미치는 영향)

  • You, Myung-Jo;Lee, John-Hwa;Kim, In-Shik;Park, Jin-Ho;Kwon, Jung-Kee;Kim, Jong-Hoon;Kim, Bum-Seok;Yu, Il-Jeoung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.486-492
    • /
    • 2007
  • Seminal plasma(SP) is usually removed from semen that is to be cryopreserved. However, some reports indicate that SP has beneficial effects on spermatozoa during chilling and freezing. The purpose of this study was to determine the effect of SP on sperm survival by adding SP to the extender before cooling and freezing canine spermatozoa. In replicate experiments, ejaculates obtained from four healthy dogs(1-4 years old) of various breeds were pooled, centrifuged at $300{\times}g$ for 10 min at $25^{\circ}C$, and the supernatant of seminal plasma was decanted. Spermatozoa were suspended in egg yolk-Tris(EYT) buffer. The study comprised two experiments: [Exp 1] Sperm were suspended in EYT extender containing either 0, 20, 40, 80 or 100% SP and were slowly cooled to $4^{\circ}C$ for 2h or held at $25^{\circ}C$ as controls. Sperm concentration was adjusted to $2{\times}10^8/ml$. [Exp II] Sperm samples, each of which contained $1{\times}10^8/ml$, were assigned to nine groups to be frozen. In the first four groups, sperm in EYT containing either 20, 40, 80 or 100% SP were cooled to $4^{\circ}C$, then diluted to contain final concentrations of EYT+0.6M glycerol and then were frozen. The final concentrations of SP were 10, 20, 40 or 50%. In the other four groups, sperm in EYT alone were first cooled slowly to $4^{\circ}C$, then diluted to contain final concentrations of EYT+0.6M glycerol plus 10, 20, 40 or 50% SP and then were frozen. Spermatozoa, which chilled in EYT alone and diluted to contain final concentrations of EYT+0.6M glycerol without seminal plasma, and then frozen, was regarded as control. Spermatozoa were frozen at $25^{\circ}C/min$ of cooling rate in plastic straws that were suspended above liquid nitrogen and thawed in water at $38^{\circ}C$ for 1 min. Sperm survival was assayed by determining progressive motility and integrity of plasma and acrosome membranes. Progressive motility was determined by microscopic examination at $200{\times}$ magnification. Membrane integrity was assessed by use of a double fluorescent dye, and acrosome integrity by staining sperm with Pisum sativum agglutinin. The results of the first experiment showed that adding SP did not improve motility of spermatozoa compared to those incubated without SP regardless of temperature. The results of the second experiment showed that spermatozoa suspended in EYT+0.6M glycerol containing SP exhibited the higher progressive motility before being frozen(P<0.05). However, frozen-thawed spermatozoa that had suspended in EYT+0.6M glycerol containing SP showed the similar or lower viability(P<0.05). In summary, although seminal plasma did not affect spermatozoa that were chilled in EYT without cryoprotectant(CPA), addition of seminal plasma to EYT containing CPA did significantly improved progressive motility of canine spermatozoa that were chilled.

Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations (두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교)

  • Shin, Ho-Sik;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.528-534
    • /
    • 2008
  • Purpose: Marginal fit is one of the important components for the successful prosthodontic restoration. Poor fitting margin of the restoration causes hypersensitivity, secondary caries, and plaque accumulation, which later result in prosthodontic failure. CAD/CAM zirconia all-ceramic restorations, such as $LAVA^{(R)}$ (3M ESPE, St.Paul, MN) and $EVEREST^{(R)}$ (KaVo Dental GmbH, Biberach, Germany) systems were recently introduced in Korea. It is clinically meaningful to evaluate the changes of the marginal fit of the CAD/CAM zirconia systems before and after build-up. The purposes of this study are to compare the marginal fit of the two CAD/CAM all-ceramic systems with that of the ceramometal restoration, before and after porcelain build-up Material and methods: A maxillary first premolar dentiform tooth was prepared with 2.0 mm occlusal reduction, 1.0 mm axial reduction, chamfer margin, and 6 degree taperness in the axial wall. The prepared dentiform die was duplicated into the metal abutment die. The metal die was placed in the dental study model, and the full arch impressions of the model were made. Twenty four copings of 3 groups which were $LAVA^{(R)}$, $EVEREST^{(R)}$, and ceramometal restorations were fabricated. Each coping was cemented on the metal die with color-mixed Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan). The marginal opening of each coping was measured with $Microhiscope^{(R)}$ system (HIROX KH-1000 ING-Plus, Seoul, Korea. X300 magnification). After porcelain build-up, the marginal openings of $LAVA^{(R)}$, $EVEREST^{(R)}$,and ceramometal restorations were also evaluated in the same method. Statistical analysis was done with paired t-test and one-way ANOVA test. Results: In coping states, the mean marginal opening for $EVEREST^{(R)}$ restorations was $52.00{\pm}11.94\;{\mu}m$ for $LAVA^{(R)}$ restorations $56.97{\pm}10.00\;{\mu}m$, and for ceramometal restorations $97.38{\pm}18.54\;{\mu}m$. After porcelain build-up, the mean marginal opening for $EVEREST^{(R)}$ restorations was $61.69{\pm}19.33\;{\mu}m$, for $LAVA^{(R)}$ restorations $70.81{\pm}12.99\;{\mu}m$, and for ceramometal restorations $1115.25{\pm}23.86\;{\mu}m$. Conclusion: 1. $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations in comparison with ceramometal restorations showed better marginal fit, which had significant differences (P < 0.05) in coping state and also after porcelain build-up . 2. The mean marginal opening values between $LAVA^{(R)}$ and $EVEREST^{(R)}$ restorations did not showed significant differences after porcelain build-up as well as in coping state (P > .05). 3. $EVEREST^{(R)}$, $LAVA^{(R)}$ and ceramometal restorations showed a little increased marginal opening after porcelain build-up, but did not show any statistical significance (P > .05).

EFFECT OF INDUCTION CHEMOTHERAPY ON FLAP SURVIVAL RATE IN MICROSURGERY (종양수술전 화학요법이 미세수술시 피판생존율에 미치는 영향)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.6
    • /
    • pp.421-429
    • /
    • 2003
  • Purpose : Neoadjuvant chemotherapy is commonly used to treat cancer patients as adjunct treatment, but if the microvascular tissue transfer is performed simulataneously with cancer resection surgery, the induction chemotherapy might affect the survival rate of vascularized free flap. Our study will focus on the effect of induction chemotherapy on the free flaps which were made on white rat abdomen after injection of 5-FU. Materials and Methods: The experimental rat groups were divided into three groups (total 24 rats) as a normal control group, 24 hrs group after 5-FU injection, 3 days group after 5-FU injection. Inferior abdominal island flaps of 8 Sprague Dawley rats on each group were made and immediately were induced into an ischemic state by clamping the supplying inferior epigastric artery and vein with microvascular clamp for a hour to induce a similiar free flap circumstance, then the inferior abdominal skin flaps were reperfused by releasing the clamps. The flaps on abdomen were repositioned and sutured. The experimental data for flap survival rate was collected by digital photo taking, analysed by computer image program to compare with the flap luminosity. The rats were sacrificed at 3 days, 5 days, 7 days after flap preparation and specimens of the flap were taken and stained with H-E staining. The microscopic finding was made under magnification of 200 and 400. Results: 1. Gross findings on each groups showed the healing condition was good as following sequences; normal, 24 hrs group after chemotherapy, 3 days group after chemotherpy. 2. The values of flap luminosity for evaluation of flap survival rate also showed the same sequences as gross findings of healing state. 3. The microscopic findings of epidermis necrosis, inflammation state, dermis fibrosis, vessel change, fatty tissue layer thinning were compared with each group. The 3 days group after chemotherapy showed remarkably poor healing condition compared to other groups. Conclusion: Chemotherapy agents affected the healing process of free flap, but healing condition was recovered spontaneously as post-injection periods passed out. In opposite to our expectation, 3 days group showed the bad flap condition in comparing with 24 hours group which was considered as immatured body circulation state of chemotherapy agent. It showed that 3 weeks in human being after chemotherapy was not proper as timing of microvascular tissue transfer if 3 days group in rat was considered as same healing period of 3 weeks in human being. More delayed healing timing than 3 weeks might be required in clinical application of free tissue transfer.

Fracture load and marginal fitness of zirconia ceramic coping by design and coloration (유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성)

  • Shin, Mee-Ran;Kim, Min-Jeong;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. Material and methods: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of $\times$ 100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. Results: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P<.05). 3. When the marginal fitness among the groups in the uncolored zirconia group was considered, group II2 had the smallest marginal discrepancy. 4. When the colored and uncolored groups with the same design were compared, there was a significant difference between I1 and II1 groups. In group 2, 3, and 4, the uncolored zirconia had the greatest marginal fitness (P<.05). 5. After adjustment of inner surface, there was no significant difference in the marginal fitness in all groups when color and design of the zirconia coping were compared. 6. The fracture load of CAD/CAM zirconia copings showed significant difference in group 1, 2, 3, and 4. I4 and II4 had the strongest fracture load. 7. When groups with different color and same design were compared, all colored groups showed greater fracture load (P>.05), with no significance. Conclusion: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.

The Effects of Diltiazem and Pentoxifylline on Apoptosis of Irradiated Rat Salivary Gland (흰쥐 침샘의 방사선조사시 Apoptosis에 대한 Diltiazem과 Pentoxifylline의 효과)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.367-375
    • /
    • 1998
  • Purpose : Xerostomia is a complication met by almost all patients who have radiotherapy for cancers of head and neck. Many studies for prevention of xerostomia will be necessary. Radiation-induced acute response of salivary glands has been defined as interphase death or apoptosis. Increased intracellular calcium level have an important role in radiation-induced apoptosis. Calcium channel blocker may prevent radiation-induced apoptosis of salivary glands. This study was designed to evaluate the effectiveness of diltiazem known as calcium channel blocker and pentoxifylline with inhibition of inflammatory response on the apoptosis as an acute response of radiation in rat salivary glands. Materials and Methods : Sprague-Dawley rats with about body weight 200-250 g were divided into 5 study groups : control, radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation. The diltiazen and pentoxifylline were injected intraperitoneally 20 mg/kg and 50 mg/kg, 30 and 20 mimute before irradiation. respectively. Irradiation was given with a 4 MV linear accelerator. The 1600 cGy of radiation was delivered in a single fraction through a single anterior portal encompassing the entire neck. After 24 h of irradiation, rats were sacrificed and parotid and submandibular glands were removed and stained with hematoxylin and eosin. The quantification of apoptosis was performed by microscopic examination of stained tissue sections at a magnification of 200X and the percentage of apoptotic cell was calculated. Results : On parotid glands, the percentage of apoptosis by radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.72$\%$ (8.35/486), 0.64$\%$ (2.9/453), 0.23$\%$ (1.2/516), and 0.28$\%$ (1.1/399), respectively. The apoptosis was markedly reduced in the groups receiving drugs compared with groups receivinge, radiation alone (p<0.05). In serous cell of submandibular glands, the percentages of apoptosis of radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.94$\%$ (l1/567), 0.34$\%$ (1.9/554), 0.28$\%$ (1.8/637), and 0.22$\%$ (1.3/601), respectively. In the mucus cell of submandibular glands, the percentages of apoptosis were 0.92$\%$ (5.1/552), 0.41$\%$ (2.5/612), 0.29$\%$ (1.3/455), and 0.18$\%$ (1.0/562), respectively. The apoptosis was markedly reduced in the serous glands (p<0.05), but there was no difference in development of apoptosis in each group of mucus gland. Conclusion : These results suggest that radiation-induced apoptosis of serous cells of salivary glands may be decreased by diltiazem and pentoxifylline administration.

  • PDF