• Title/Summary/Keyword: magnetic probe

Search Result 262, Processing Time 0.022 seconds

Development of Magnetic Phase Detection Sensor for the Steam Generator Tube in Nuclear Power Plants

  • Son, De-Rac;Joung, Won-Ik;Park, Duck-Gun;Ryu, Kwon-Sang
    • Journal of Magnetics
    • /
    • v.14 no.2
    • /
    • pp.97-100
    • /
    • 2009
  • A new eddy current testing probe was developed to separate the eddy current signal distortion caused by permeability variation clusters and ordinary defects created in steam generator tubes. Signal processing circuits were inserted into the probe to increase the signal-to-noise ratio and allow digital signal transmission. The new probe could measure and separate the magnetic phases created in the steam generator tubes in the operating environment of a nuclear power plant. Furthermore, the new eddy current testing probe can measure the defects in steam generator tubes as rapidly as a bobbin probe with enhanced testing speed and reliability of defect detection.

A Study on Magnetized Inductively Coupled Plasma Using Cutoff Probe (Cutoff Probe를 이용한 자화유도결합 플라즈마의 특성 연구)

  • Son, Eui-Jeong;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1706-1711
    • /
    • 2016
  • Electromagnetic wave simulation was performed to predict characteristics of manufactured cutoff probe at low temperature magnetized plasma medium. Microwave cutoff probe is designed for research the properties of magnetized inductively coupled plasma. It was shown that the cutoff probe method can safely be used for weakly magnetized high density plasma sources. Cutoff probe system with two port network analyzer has been prepared and applied to measure electron density distributions in large area, 13.56MHz driven weakly magnetized inductively coupled plasma source. The results shown that, the plasma frequency confirmed cut-off characteristics in low temperature plasma. Especially, cut-off characteristics was found at upper hybrid resonance frequency in the environment of the magnetic field. In case of a induced weak magnetic field in inductively coupled plasma, plasma density estimated from the cutoff frequency in the same way at unmagnetized plasma due to nearly same plasma frequency and upper hybrid resonance frequency. The plasma density is increased and uniformity is improved by applying a induced weak magnetic field in inductively coupled plasma.

Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension (자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구)

  • 김의석;안형준;장인배;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe (Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석)

  • Lee, H.Y.;Kwak, K.S.;Rhyee, J.K.;Yoo, J.;Youm, D.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.

Low-ε Static Probe Development for 15N-1H Solid-state NMR Study of Membrane Proteins for an 800 MHz NB Magnet

  • Park, Tae-Joon;Choi, Sung-Sub;Jung, Ji-Ho;Park, Yu-Geun;Kim, Yongae
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.823-826
    • /
    • 2013
  • A low-${\varepsilon}$ solid-state NMR(Nuclear Magnetic Resonance) probe was developed for the spectroscopic analysis of two-dimensional $^{15}N-^1H$ heteronuclear dipolar coupling in dilute membrane proteins oriented in hydrated and dielectrically lossy lipid environments. The system employed a 800 MHz narrow-bore magnet. A solenoid coil strip shield was used to reduce deleterious RF sample heating by minimizing the conservative electric fields generated by the double-tuned resonator at high magnetic fields. The probe's design, construction, and performance in solid-state NMR experiments at high magnetic fields are described here. Such high-resolution solid-state NMR spectroscopic analysis of static oriented samples in hydrated phospholipid bilayers or bicelles could aid the structural analysis of dilute biological membrane proteins.

A Three-dimensional Magnetic Field Mapping System for Deflection Yoke of Cathode-Ray Tube

  • Park, K.H.;Yoon, M.;Kim, D.E.;Lee, S.M.;Joo, H.D.;Lee, S.D.;Yang, W.Y.
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we introduce an efficient three-dimensional magnetic field mapping system for a Deflection Yoke (DY) in Cathode-Ray Tube (CRT). A three-axis Hall probe mounted in a small cylindrical bar and three-stepping motors placed in a non-magnetic frame were utilized for the mapping. Prior to the mapping starts, the inner contour of DY was measured by a laser sensor to make a look-up table for inner shape of DY. Three-axis magnetic fields are then digitized by a three-dimensional Hall probe. The results of the mapping can be transformed into various output formats such as multi pole harmonics of magnetic fields. Field shape in one, two and three- dimensional spaces can also be displayed. In this paper, we present the features of this mapping device and some analysis results.

Analysis for Shielding Effectiveness of Metal Shielding Layer within Near-Field of Noise Source (노이즈 소스 근거리장에 위치한 금속 차폐막의 차폐효과 분석)

  • Lee, Won-Seon;Lee, Won-Hui;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.59-65
    • /
    • 2019
  • The EMI shielding effectiveness of the shielding layer thickness was analyzed when the metal shielding layer was placed in the near field of the magnetic probe and the noise source. Microstrip lines were used as noise source, and graphite and ferrite were selected as metal shielding materials. The magnetic probe uses the electromagnetic radiation measurement method using the magnetic probe by applying the IEC 61967-6 method. The transmission coefficient between the microstrip line and the magnetic probe was analyzed. The distance between the two was 1 mm for a single shielding layer and 5 mm for a multiple shielding layer. The thickness of the shielding layer was changed to 5 um, 10 um, 30 um, and 50 um. When the frequency was changed from 150 kHz to 1 GHz, a maximum shielding effectiveness (SE) of 44.9 dB was obtained.

A study on the characteristics of axially magnetized capacitively coupled radio frequency plasma (축 방향으로 자화된 용량 결합형 RF 플라즈마의 특성 연구)

  • 이호준;태흥식;이정해;신경섭;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.112-118
    • /
    • 2001
  • Magnetic field is commonly used in low temperature processing plasmas to enhance the performance of the plasma reactors. E$\times$B magnetron or surface multipole configuration is the most popular. However, the properties of capacitively coupled rf plasma confined by axial static magnetic field have rarely been studied. With these background, the effect of magnetic field on the characteristics of capacitively coupled 13.56 MHz/40 KHz argon plasma was studied, Ion saturation current, electron temperature and plasma potential were measured by Langmuir probe and emissive probe. At low pressure region (~10 mTorr), ion current increases by a factor of 3-4 due to reduction of diffusion loss of charged particles to the wall. Electron temperature slightly increases with magnetic field for 13.56 MHz discharge. However, for 40 KHz discharge, electron temperature decreased from 1.8 eV to 0.8 eV with magnetic field. It was observed that the magnetic field induces large temporal variation of the plasma potential. Particle in cell simulation was performed to examine the behaviors of the space potential. Experimental and simulation results agreed qualitatively.

  • PDF

A pin type current probe using Planar Hall Resistance magnetic sensor (PHR 자기센서를 적용한 탐침형 전류 프로브)

  • Lee, Dae-Sung;Lee, Nam-Young;Hong, Sung-Min;Kim, CheolGi
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.342-348
    • /
    • 2021
  • For the characterization or failure analysis of electronic devices such as PCB (printed circuit boards), the most common method is the measurement of voltage waveforms with an oscilloscope. However, because there are many types of problems that cannot be detected by voltage waveform analysis, several other methods such as X-ray transmission, infrared imaging, or eddy current measurement have been applied for these analyses. However, these methods have also been limited to general analyses because they are partially useful in detecting physical defects, such as disconnections or short circuits. Fundamentally current waveform measurements during the operation of electronic devices need to be performed, however, commercially available current sensors have not yet been developed, particularly for applications in highly integrated PCB products with sub-millimeter fine pitch. In this study, we developed a highly sensitive PHR (planar hall resistance) magnetic sensor for application in highly integrated PCBs. The developed magnetic sensor exhibited sufficient features of an ultra-small size of less than 340 ㎛, magnetic field resolution of 10 nT, and current resolution of 1 mA, which can be applicable for PCB analyses. In this work, we introduce the development process of the magnetic sensing probe and its characteristic results in detail, and aim to extend this pin-type current probe to applications such as current distribution imaging of PCBs.

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.