• Title/Summary/Keyword: magnetic measurement

Search Result 1,247, Processing Time 0.035 seconds

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)

Magnetic Field Strength Measurement using Circular Loop Antenna (환상 루-프 안테나를 이용한 자기장 세기의 측정)

  • 박병권;강찬구;김정환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.6
    • /
    • pp.566-573
    • /
    • 1991
  • For the evaluation of the magnetic field strengthmeasured by standard field method with that measured by standard antenna method. The compared results are in good agreement within the error limit. As the Result of this research, the calibration service for magnetic field strenth measurement can be provided whtin the uncertainty of about 1 dB in the frequency range of 10 kHz to 30MHz.

  • PDF

Microstructural and Magnetic Characterization of Fe Nanosized Powder Synthesized by Pulsed Wire Evaporation

  • Kim, Deok Hyeon;Lee, Bo Wha
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.100-103
    • /
    • 2017
  • We studied the microstructure and magnetic properties of Fe nanosized powder synthesized by the pulsed wire evaporation method. The x-ray diffraction spectrum confirmed that this powder had a pure ${\alpha}$-Fe phase. Scanning electron microscope and transmission electron microscope measurements indicated that the prepared powder had uniform spherical shape with core-shell structure. The mean powder size was about 35 nm and the thickness of the surface passivation layer was about 5 nm. Energy dispersive X-ray spectroscopy measurement indicated that the surface passivation layer was iron oxide. Magnetic field dependent magnetization measurement at room temperature showed that the maximum magnetization of the prepared powder was 177.1 emu/g at 1 T.

Test method study about characteristic of static states for Maglev LIM (자기부상열차용 선형유도전동기 정특성 시험방법에 대한 연구)

  • Kim, Jung-Chul;Kim, Bong-Chul;Kim, Dea-Kwang;Park, Yeong-Ho;Kim, Chul-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.549-554
    • /
    • 2008
  • The recent trains are almost being operated by the mechanical propulsion force to drive the gear and wheel with the traction motor. However Magnetic Levitation Vehicle is differently operated. Magnetic Levitation Vehicle is applied with Linear Induction Motor(LIM) that has many advantage like to high capability of going up to slope, low noise, easy to control of speed. So domestic and many advanced countries are interested in Magnetic Levitation Vehicle and they have been studying about it continuously. Thus this paper is studied the LIM test method of static states and guess the optimum driving point by characteristic of static states for LIM. The test items are measurement of thrust force by changed air gap, measurement of thrust force and normal force by changed slip frequency etc.

  • PDF

Characteristics and Measurement Method of the Underwater Electromagnetic Signature Emitted from a Naval Ship (함정 발생 수중 전자기장 신호의 특성 및 측정 기법)

  • Yang, Chang-Seob;Chung, Hyun-Ju;Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.11-19
    • /
    • 2006
  • The underwater electromagnetic signatures of a naval ship are mainly generated from three sources which are the permanent and induced magnetic field in the ship's hull and other ferrous components, the cathodic current electromagnetic field established by the Impressed Current Cathodic Protection(ICCP) system or the Sacrificial Anode and the stray electromagnetic fields generated by onboard equipment. These signatures can be minimized by certain design methods or installation of signature reduction equipment. In this paper, we represented the characteristic of the underwater electromagnetic signature and the signature reduction techniques for a naval ship. Also, we measured the electromagnetic field changes emitted from the real ship using the Electric and Magnetic field Measurement System(EMMS). We found that the underwater electromagnetic signature for a naval ship can be used as input or trigger signal in a surveillance system and an influence mine.

Improvement of Magnetic SE Measurement of Shielded Rooms Using Rectangular Loop Antennas (직사각형 루프 안테나를 이용한 차폐실의 자기장 차폐효과 측정 방법 개선)

  • Park, Hyun Ho;Hyoung, Chang Hee;Kwon, Jong Hwa
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.320-323
    • /
    • 2019
  • This paper examines a disadvantage of low-frequency magnetic shielding measurement based on MIL-STD-188-125-1. A rectangular loop antenna is proposed as an improvement over conventional circular loop antennas for measuring magnetic shielding. Simulation and experiment are used to demonstrate that the proposed rectangular loop outperforms the circular loop for a more reliable shielding measurement at low frequency range.

Substrate-free Biosensing using Brownian Rotation of Bio-conjugated Magnetic Nanoparticles

  • Chung Seok-Hwan;Hoffmann Axel;Chen, Liaohai;Sun, Shouheng;Guslienko Konstantin;Grimsditch Marcos;Bader Samuel D.
    • Journal of Magnetics
    • /
    • v.11 no.4
    • /
    • pp.189-194
    • /
    • 2006
  • The recent development of bio-conjugated magnetic nanoparticles offers many opportunities for applications in the field of biomedicine. In particular, the use of magnetic nanoparticles for biosensing has generated widespread research efforts following the progress of various magnetic field sensors. Here we demonstrate substrate-free biosensing approaches based on the Brownian rotation of ferromagnetic nanoparticles suspended in liquids. The signal transduction is through the measurement of the magnetic ac susceptibility as a function of frequency, whose peak position changes due to the modification of the hydrodynamic radius of bio-conjugated magnetic nanoparticles upon binding to target bio-molecules. The advantage of this approach includes its relative simplicity and integrity compared to methods that use substrate-based stray-field detectors.

A Study on the Sensorless Realization of Magnetic Levitation System (자기 부상계의 센서리스 실현에 관한 연구)

  • 김창화;정병건;양주호
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.195-203
    • /
    • 1998
  • The magnetic levitation system is utilized in the magnetic bearing of high-speed rotor because of little friction, no lubrication, no noise and so on. The magnetic levitation system need the feedback controller for the stabilization of system, and gap sensors are generally used to measure the gap. The use of sensor easily goes into troublesome caused by sensor failure discord between the measurement point and the control point etc. This paper presents the design of robust stabilizing contoller by $H_{\infty}$ control theory using the sensorless method proposed by authors in the magnetic levitation system. And we investigated both the validity of the designed controller and the usefulness of the sensorless magnetic levitation system through results of actual experiment.

  • PDF

Occurrence Mechanism of Magnetic Properties in BiSrCaCuO Superconductor (산화물 초전도체의 자기적 특성 발생 메커니즘)

  • Lee, Sang-Heon
    • Journal of Powder Materials
    • /
    • v.13 no.6 s.59
    • /
    • pp.439-444
    • /
    • 2006
  • An electromagnetic properties in BiSrCaCuO superconductor were studied. In the measurement of current-voltage properties, the voltage was measured when applying an external magnetic field. The voltage continues to appear after the removal of the magnetic field. This phenomenon was considered as a nonvolatile magnetic effect. The voltage increased with the applied magnetic flux, but it became constant at about $10^{-2}$T. The appearance of the voltage was ascribed to the trapping of magnetic flux.

Magnetic Shielding Effectiveness Measurement of Magnetic Steel Sheets in ELF Range

  • Yeon, Kyo-Heum;Son, Derac;Park, Eon-Byeong;Lee, Jae-Young;Do, Kyung-Hwan;Park, Jae-Seg
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.173-176
    • /
    • 2008
  • In this study, a new kind of instrument for measuring the magnetic shielding effectiveness (MSE) was developed using a double yoke; one a magnetizing yoke and the other a sensing yoke. Using the developed instrument, the MSE could be measured for a steel sheet specimen in the ELF range, where the magnetic permeability contributes to the MSE at low frequencies and eddy currents contributes to the MSE high frequencies with < 0.1 dB reproducibility. The developed measuring method can be applied to quality control in a steel sheet company producing EMI/EMC shielding materials.