Browse > Article
http://dx.doi.org/10.5515/KJKIEES.2019.30.4.320

Improvement of Magnetic SE Measurement of Shielded Rooms Using Rectangular Loop Antennas  

Park, Hyun Ho (School of Electrical and Electronic Engineering, The University of Suwon)
Hyoung, Chang Hee (Broadcasting & Media Research Laboratory, Electronics and Telecommunications Research Institute)
Kwon, Jong Hwa (Broadcasting & Media Research Laboratory, Electronics and Telecommunications Research Institute)
Publication Information
Abstract
This paper examines a disadvantage of low-frequency magnetic shielding measurement based on MIL-STD-188-125-1. A rectangular loop antenna is proposed as an improvement over conventional circular loop antennas for measuring magnetic shielding. Simulation and experiment are used to demonstrate that the proposed rectangular loop outperforms the circular loop for a more reliable shielding measurement at low frequency range.
Keywords
Shielded Room; Circular Loop Antenna; Rectangular Loop Antenna; Slot; MIL-STD-188-125-1; Unit Test Area;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 MIL-STD-188-125-1, "High-altitude electromagnetic pulse (HEMP) protection for ground-based C41 facilities performing critical, time-urgent missions, Part 1 fixed facilities," Apr. 2005.
2 정연춘, 이종경, 권석태, "HEMP 방호시설의 SE 평가방법의 비교," 한국전자파학회논문지, 25(11), pp. 1197-1200, 2014년.   DOI
3 서만중, 지성원, 김영진, 박우철, 강호재, 허창수, "EMP 방호시설의 전자파 차폐효과 측정 방법," 한국전자파학회논문지, 25(5), pp. 548-548, 2014년 5월.   DOI
4 CST. (2012) Microwave Studio (MWS) [Online]. Available: https://www.cst.com