• Title/Summary/Keyword: machine center

Search Result 1,819, Processing Time 0.033 seconds

Effect of Ground-fogging on Target and Non-target Insects in Korean Pine Forests (지상 연막 방제가 잣나무림 내 표적 및 비표적 곤충에 미치는 영향)

  • Jang, Tae Woon;Jung, Jong-Kook;Kim, Mannyeon;Kim, Jongkuk;Jung, Chansik;Koh, Sanghyun
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.4
    • /
    • pp.509-517
    • /
    • 2017
  • This study was conducted to assess effect of thiacloprid fogging on non-target insect communities in Korean white pine forests. In addition, we assessed effect of thiacloprid fogging on mortality of Monochamus saltuarius as a vector of pine wood nematodes, and Apis mellifera as a non-target species. We compared abundance, species richness, and compostion of insects, and mortality of two insects among four treatment groups (control and thiacloprid-fogged groups with 3 different doses) located in the Kangwon National University Forest. For sampling of insects, 6 pitfall and 2 multi-funnel traps and 3 waterproof cloth sheets were placed in each study plot. In addition, M. saltuarius and A. mellifera were put into each meshed cage which installed at 7 m and 15 m heights in center of each study plot. Thiacloprid was fogged only once (middle May) in each plot using a fogging machine. Overall, thiacloprid fogging was appeared to be low toxicity to the abundance, species richness, and compostion of insects and mortality of A. mellifera, while it seems effectively impact on the mortality of M. saltuarius. However, thiacloprid fogging seems more influenced by microclimates in forests because the mortality of M. saltuarius in mesh cages was different according to heights and spatial locations. To control the population density and dispersal of M. saltuarius using by fogging techniques, therefore, it may be necessary to minimize the uncertainty about the effectiveness of thiacloprid fogging by improving the fogging techniques.

Investigation of Varied MR Spectra by TE and Metabolite Amount in the Localized Voxel using the MR Cone-shape Phantom (자기공명분광법에서 TE와 Voxel 내의 대사물질 양에 따른 스펙트럼 변화 평가에 관한 연구)

  • Woo, Dong-Cheol;Kim, Sang-Soo;Rhim, Hyang-Shuk;Jahng, Geon-Ho;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.179-185
    • /
    • 2007
  • The purpose of this study is to investigate the spectra of a magnetic resonance spectroscopy (MRS) in accordance with the variance of TE and the volumes of metabolites in a localized voxel for the quality assurance using a designed single voxel spectroscopy QA phantom. Because a cone-shade phantom is designed as the volume of metabolite in a localized voxel is changeable, we try to analyze the peaks of each metabolite (NAA, Cr, Cho, Lac, etc.) in accordance with metabolite volume in a localized voxel as well as echo time (TE). All data were obtained using a 3T MRI/MRS machine and analyzed using $jMRUI^{(R)}$. The results of this study show that TE is in inverse proportion to the noise of MRS and the longer TE and the less metabolite volume in the localized voxel, the peak intensities of each metabolite decrease. In case of the lactate, its peak was observed on the all TE only if the greatest metabolite is included in the localized voxel. Then, the intensity of a metabolite is more sensitive to the metabolite volume in the localized voxel than the TE. These obtained in vitro MRS data is provide the guideline that is important for in vivo metabolite quantification. But, in the edge of cone-shape vial air bubbles were observed and spectrum could not obtained. Therefore our cone-shape MRS phantom needs to be modified in order to solve these problems.

  • PDF

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Comparison of Bentgrass Recovery Speed on Golf Green Followed by Methods of Ball Mark Repair Practise (골프장 그린의 볼마크 수리방법에 따른 벤트그래스의 회복속도 비교)

  • Park, Jong-Hwa;Lee, Jae-Phil;Kim, Doo-Hwan;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.24 no.2
    • /
    • pp.211-217
    • /
    • 2010
  • This study was conducted to investigate a proper method of ball mark repair by comparing the creeping bentgrass recovery speed on golf course green treated by various methods of ball mark repair. Nine general repairing methods were tested and compared; control (no repair, A type), two common methods of USGA (B type) and GCSAA (C type), three methods with fork shaped hand set performing at Korean golf courses (Ansung Benest, D; Sky72, E; Lakeside, F type), and three methods using the repair machine with 6, 8, or 14 teeth (G, H, I type, respectively). Three creeping bentgrass cultivar of 'Penncross', 'T-1', and 'CY-2' were tested in this field experiment. This test was carried out from September to November in 2009 at the nursery on the Seoul Lakeside Golf course. The average speed of turfgrass recovery after various ball mark repairing methods have been ranked as in the order of E, D, C, B, F, I, H, G, and A. The methods of hand practise showed more effective results than repair method using machines. The ball mark recovery speeds of 'Penncross' were in the order of E, D, B, C, F, I, H, and A. In the case of 'T1' and 'CY-2', similar orders were showed as D, E, B, F, C, H, I, A, G and the order of D, E, C, F, B, H, G, I, A, respectively. The ball mark recovery speed among creeping bentgrass cultivar resulted in the order of 'CY-2', 'Penncross', and 'T-1'. The most proper method of ball mark repair was repair method using a hand set tool especially the method of the Sky72 Golf course (E type). At the first, remove a damaged grass area with fork and tap. And then gather the side grasses into the center area with pulling the grasses with fork. After that, make harden and flat on the turf surface by pounding and rolling with the round wooden stick. The final Nstep, water the repaired grass surface. This ball mark repairing practise showed a most rapid and proper recovery method on creeping bentgrass green.

Effect of Processing Additives on Vulcanization and Properties of EPDM Rubber (EPDM 고무의 첨가제에 따른 가류 및 물성에 미치는 영향 연구)

  • Lee, Soo;Bae, Joung Su
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.173-185
    • /
    • 2018
  • Effects of three different types of dispersions and flow improving additives composed with fatty acid esters, fatty acid metal salts and amide compound on the vulcanization and the mechanical properties properties of rubber compounds of EPDM and carbon black as fillers. were investigated using Mooney viscometer, moving die rheometer, hardness tester, and universal test machine. The aging characteristics of vulcanized EPDM compounds were also investigated. The Mooney viscosity measured at $125^{\circ}C$ showed a tendency to decrease in the order of amide type> metal salt type > ester type additive. Scorch time showed little or no difference with the addition of ester or metal salt type additives, but the amide type additive shortened a scorch time more than one minute. Rheological measurement data obtained at $160^{\circ}C$ showed that the vulcanization time was faster for metal salt type and amide type additive systems. Delta torque values of EPDM compound increased with metal salt type and amide type additives, but slightly decreased with ester type additive. The tensile strength of the EPDM compound was greatly improved when an ester type additive was added, but the amide type or metal salt type additive had no significant effect. The elongation was significantly improved for metal salt type additive, while the rest were not significantly affected. The tear strength of the EPDM compounds increased with the addition of all kinds of additives, and it increased remarkably in the case of metal salt type additive. Hardness of the EPDM compounds was nearly same value regardless of additive types. The thermal aging of the EPDM blend at $100^{\circ}C$ for 24 h showed little change in the case of metal salt type or amide type additive, but the elongation tends to decrease by 10-20% for all EPDM compounds containing additives.

Incidence of Rice stripe virus during 2002 to 2004 in Korea and Chemical Control of Small Brown Plant Hopper (2002-2004년의 벼줄무늬잎마름병 발생상황 및 약제처리에 의한 애멸구의 화학적 방제)

  • Park, Jin-Woo;Jin, Tae-Seong;Choi, Hong-Soo;Lee, Su-Heon;Shin, Dong-Bum;Oh, In-Seok;Lee, Sang-Guei;Lee, Min-Ho;Choi, Byeong-Ryeol;Bae, Soon-Do;Kim, Jin-Young;Han, Kwang-Seop;Noh, Tae-Hwan;Ko, Sug-Ju;Park, Jong-Dae;Lee, Bong-Choon;Kim, Tae-Sung;Chung, Bu-Keun;Hong, Sung-Jun;Kim, Choong-Hoe;Park, Hyung-Man;Lee, Key-Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.13 no.4
    • /
    • pp.309-314
    • /
    • 2009
  • Incidence of rice stripe disease, caused by Rice stripe tenuivirus (RSV), was surveyed during 2002 to 2004. The incidence area and ratio of diseased fields were decreased gradually during those period. Rate of diseased plants were 45.8%, 45.0% and 43.7% in the susceptible cultivars Chucheong, Saechucheong and Ilpum, respectively. However, the rate was 4.4% in resistant cultivar Hwaseong. In addition, breakdown rate was also significantly high in the susceptible cultivars in Chucheong, Saechucheong and Ilpum showing 33.6, 33.2 and 31.9%, respectively. In Hwaseong, the breakdown rate was 0.8%. Collection efficiency was compared between two insect vector collection methods. Insect-sucking machine method was much more efficient than sweeping net method in collecting small brown plant hopper (SBPH). According to the survey of the population density of the insect vector during 2002 to 2004, the national average population density was gradually decreased year by year, 3.6, 2.3, and 1.3%, respectively. This result was significantly related with the decrease of the incidence of rice stripe disease. Control efficiency of rice stripe disease by treating several seedling box and water surface with insecticides against SBPH resulted that imidacloprid GR, Fipronil FG, Clothianidin+Probenazole GR and Thiamethoxam GR showed over 80% of control efficiency at 28 days after treatment at the early stage in nursery.

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

SNR and ADC Value Change before and after the injection of contrast medium during DWI test on metastatic spinal cancer patients (전이성 척추암 환자의 확산강조영상 검사 시 조영제 주입 전.후 ADC값의 변화에 대한 고찰)

  • Kim, Eng-Chan;Kim, Ki-Hong;Park, Cheol-Soo;Lee, Sun-Yeob;Yoo, Heung-Joon;Cho, Jae-Hwan;Jang, Hyun-Cheol;Kim, Bo-Hui;Han, Man-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • To examine the possible changes in the SNRs, CNRs, and ADC values for lumbar spines with metastasis based on the DW images before and after contrast agent injection taken from metastatic spinal cancer patients using a 1.5 T MR machine. The quantitative analysis revealed that in case of spinal cancer subjects, both SNRs and CNRs at all of those assessed locations significantly increased on the DWI after contrast agent injection compared to before, while on the ADC map images, SNRs significantly decreased. On the other hand, significantly decreased ADC values at all the assessed locations were found on the ADC map images. With reference to the normal group, significantly increased SNRs were found at all of the assessed locations on the DWI image after injection compared to before, while significantly decreased SNRs were found on the ADC map images. Also, significantly decreased ADC values at all the assessed locations were found on the ADC map images. For the qualitative analysis, after contrast agent injection, significantly increased signal intensities were found at the locations with spinal cancer on the DWI. In contrast, significantly decreased signal intensities were found on the ADC map images. The implication from the results showing that SNR and CNR significantly increased while ADC value significantly decreased at, above, and below the location of metastatic spinal cancer on DWI after contrast agent injection is that DWI obtained after contrast agent injection can be made available for wider application to vertebral disorders.

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.

DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION (박스 형태의 복합레진 수복시 충전법 및 와동벽에 따른 결합력 차이에 관한 연구)

  • Ko, Eun-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.350-355
    • /
    • 2009
  • Bond strength depends on characteristics of bonding surface and restorative technique. The majority of studies dealing with dentin bond strength were carried out on flat bonding surface, therefore, difference of bond strength between axial wall and pulpal wall is not clear yet. This study evaluated bonding difference between cavity walls in class I composite resin restoration with different filling techniques. Twenty extracted caries-free human third molars were used. Cavities were prepared in 6 ${\times}$4 ${\times}$3 mm box-type and divided into four groups according to filling technique and bonding surface: Group I; bulk filling - pulpal wall, Group II; bulk filling - axial wall, Group III; incremental filling - pulpal wall, Group IV; incremental filling - axial wall. Cavities were filled with Filtek $Z250^{(R)}$(3M/ESPE., USA) and Clearfill SE $bond^{(R)}$(Kuraray, Japan). After 24 hour-storage in $37^{\circ}C$water, the resin bonded teeth were sectioned bucco-lingualy at the center of cavity. Specimens were vertically sectioned into 1.0 ${\times}$1.0 mm thick serial sticks perpendicular to the bond surface using a low-speed diamond saw (Accutom 50, Struers, Copenhagen, Denmark) under water cooling. The trimmed specimens were then attached to the testing device and in turn, was placed in a universal testing machine (EZ test, Shimadzu Co., Kyoto, Japan) for micro-tensile testing at a cross-head speed of 1 mm/min. The results obtained were statistically analyzed using 2-way ANOVA and t-test at a significance level of 95%. The results were as follows: 1. There was no significant difference between bulk filling and incremental filling. 2. There was no significant difference between pulpal wall and axial wall, either. Within the limit of this study, it was concluded that microtensile bond strength was not affected by the filling technique and the site of cavity walls.