Objective: The purpose of this study is to determine the priority of information presentation and the effective menu type to be placed in the center of a gauge cluster display for commercial trucks and to present a set of ergonomic designs for the gauge cluster display. Background: An effective ergonomic design is specifically needed for the development of the gauge cluster display for the commercial trucks, because more diverse and heavier information is delivered to truck drivers, compared to the information to passenger car drivers. Method: First, all the information that must be shown on the commercial truck display was collected. Then, the severity, frequency of use, and display design parameters were evaluated for those information by commercial truck drivers. Next, an analysis on the information attributes and the heuristic evaluation utilizing the display design principles were carried out. According to the results, a design alternative of the main screen to be displayed was constructed by priority. A comparative analysis between the alternative and existing main screens was also conducted to see the efficacy of the designs. Lastly, we conducted an experiment for the selection of menu type. The experiment was conducted using the driving simulator with an eye-tracking device. The independent variables were four types of the menu reflecting the commercial truck characteristics such as grid type, icon type, list type, and flow type. We measured preference, total execution time, the total duration of fixation on the gauge cluster area, and the total number of fixation on the gauge cluster area as dependent variables. Results: Four types of driver convenience information and six types of driver assistance information were selected as the information to be placed primarily on the main screen of the gauge cluster. The Grid type was the most effective among the menu types. Conclusion: In this study, the information that appears on the main screen of the display, the division of the display and the design of the menu type for commercial truck drivers were suggested. Application: This study is expected to be utilized as guidelines on the ergonomic design of a gauge cluster display for commercial trucks.
솔레노이드 밸브는 구조에 따라 스풀 밸브와 포핏 밸브로 구분된다. 구조가 단순하고 오염에 민감한 스풀 밸브에 대하여 연구가 많이 진행되고 있는 반면 오염에 덜 민감하고 장시간 작동에 용이한 포핏 밸브는 구조가 복잡하여 여전히 많은 연구가 필요하다. 포핏 밸브를 설계하기 위해서 고려해야 하는 사항으로 포핏의 직경, 포핏의 각도, 디스크의 지름, 스프링 강성, 스프링 예하중, 유로 구조 등 다양한 설계변수가 있다. 기존 연구에서는 설계변수를 한가지로 선정하여 연구가 진행되었고, 설계변수가 포핏 밸브의 유동특성에 미치는 영향에 대한 연구가 부족하다. 본 논문에서는 3/2Way 솔레노이드 밸브용 포핏 밸브의 설계변수 변화에 따른 유동특성의 변화를 분석하였다. 포핏 밸브의 설계변수 선정은 선행연구된 사례와 초기모델해석결과를 참고하여 진행하였다. 그리고 설계변수에 따른 최대압력, 최소압력, 압력강하의 영향을 평균분석(ANOM)을 사용하여 살펴보았다. 향후 3/2Way 솔레노이드 밸브용 포핏 밸브를 설계할 때 주효과를 파악하여 설계변수 선정에 사용하면 효율적인 설계변수 선정이 가능할 것으로 예상된다.
Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
The Journal of Advanced Prosthodontics
/
제5권3호
/
pp.287-295
/
2013
PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.
방사선(放射線)의 의학적(醫學的) 진단치료(診斷治療) 이용률(利用率)이 증가(增加)함에 따라 의료인(醫療人)과 환자(患者)들에 대한 방사선(放射線) 피폭확률(被曝確率)이 비예적(比例的)으로 증가(增加)되어 정량적(定量的)인 분석(分析)과 피폭관리(被曝管理)의 필요성(必要性)이 요구(要求)되고 있다. 연세(延世) 암센터는 암치료(癌治療)를 위하여 설치사용(設置使用)되고 있는 의료용(醫療用) 고(高)에너지 선형가속기(線型加速器)에 대한 누출(漏出) 및 산난선(散亂線)의 방어벽(防禦壁)과 방어계획(防禦計劃)이 이미 준비(準備)되어 있다. 그러나 장치(裝置)의 사용빈도(使用頻度)가 증가(增加)됨에 따라 치료실내(治療室內)의 공간(空間) 선량분포(線量分布)와 광핵반응(光核反應)으로 인한 유도방사능(誘導放射能)의 위험성(危險性)을 인식(認識)하고 이들에 대한 노출량(露出量)을 전리함(電離函), 열형광측정기(熱螢光測程器) 및 에너지 분석기등(分析器等)을 이용(利用)하여 측정(測定)하였다. 18 MeV 전자선(電子線)에 의한 실중선량(室中線量)은 1 m 지점(地點)에서 종양선량(腫瘍線量)의 0.02%였고 X-선(線)에 의한 실중선량(室中線量)은 약(約) 0.12%였다. 선형가속기(線型加速器)에서 10 MV X-선(線)을 30 Gy 조사(照射)한 직후 광핵반응(光核反應)에 의한 유도방사능(誘導放射能)을 측정(測定)한 결과(結果) 0.65 mR/hr 였으며 광핵반응(光核反應)에 의한 중성자(中性子) 방사화(放射化)는 주로 Cu-64, W-185, Mo-94, Ta-182등(等)의 원소(元宵)로 추정(推定)할 수 있었다.
Statement of problem. Glass fiber post is one of recent developments to accommodate esthetic restoration for endodontically treated teeth. This has many advantages over conventional post system in physical properties, esthetic factor, risk of root and restoration fracture, adhesion to core, radiopacity, removal and retrievabilty, biocompatibility and chemical stability. Purpose. This in vitro study was to evaluate the most suitable type of resin core for the glass fiber post through surveying the fracture modes and the maximum load that fractures the tooth. Material and methods. 50 sound maxillary premolars restored with glass fiber posts($ParaPost^{(R)}$ Fiber White) and different types of resin cores(ParaCore, $Z100^{TM}$, $Rebilda^{(R)}$ and $Admira^{(R)}$) were prepared and loaded to faiure in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with resin and those of metal cast and core. With the data, Wilcoxon rank sum test was used to validate the significance between the test groups, and Tukey' s studentized range test was used to check if there is any significant statistical difference between each test group. Every analysis was approved with 95% reliance. Results. On measuring the maximum fracture load of teeth specimens, there was a significant difference between the maximum fracture loads of the tooth specimens. ParaCore showed the highest mean maximum fracture load followed by $Z100^{TM}$. And, the distribution of fracture mode of tooth specimens showed generally Type D, the three parted fracture of the core around the post was mostly seen(62.5%), and specifically, ParaCore showed 90% and $Z100^{TM}$ showed 100% Type D fracture. Conclusion. Referring to the values of maximum fracture load and mean compressive fracture load, ParaCore and $Z100^{TM}$ had high values and are recommended as tooth colored resin core material for glass fiber post. CLINICAL IMPLICATIONS. This study was carried out intending to be of aid in selecting the appropriate resin core for the glass fiber post. The dual cure type composite resin ParaCore and light cure type composite resin $Z100^{TM}$ have good properties and are recommended as tooth colored resin core material for glass fiber post.
하악절흔 내측 함요는 하악골의 하악절흔 전, 내, 하방에 함몰된 양상으로 나타나는 정상 해부학적 구조물이다. 이 구조물에 대한 해부학적 중요성이나, 발생이 선천적인가 아니면 출생 후 발생되는 것인가에 대하여는 알려져 있지 않다. Langlais는 하악절흔내측함요는 파노라마 방사선사진상에서 절흔, 또는 소공 모양의 방사선투과상으로 나타난다고 하였지만 이는 하악사측방향 촬영상 등에서도 나타날 수 있는 해부학적 구조물이다. 파노라마 방사선사진에서는 익상판, 연구개, 기도, 그외 다른 조직 등의 중첩으로 인하여, 이 구조물의 발견 빈도가 낮아진다. 저자는 78개의 하악골에서의 발생빈도, 위치, 크기 등을 조사하고, 이를 파노라마 방사선사진촬영하여 그 발생 빈도를 조사하였으며, 치과환자 500명의 파노라마 방사선사진에서의 발생 빈도도 알아보았다. 1. 하악골에서의 발생빈도는 62%였다(편측성 28%, 양측성 33%). 2. 하악골의 파노라마 방사선사진상의 발생빈도는 33%였다(편측성 14%, 양측성 19%). 3. 하악절흔내측함요의 중심 위치는 하악절흔 하방 6.0㎜, 전방 3.8㎜였다. 4. 크기는 수직 7.8㎜, 수평 8.3㎜이였다. 5 치과환자들의 파노라마 방사선사진상에서의 발생 빈도는 24%였다(편측성 18%, 양측성 7%).
Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
대한치과보철학회지
/
제39권6호
/
pp.599-610
/
2001
Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.
Purpose : The purpose of this study was to investigate the effect of the output energy(voltage) of laser welding on the strength and properties of joint of cast titanium(CP Gr II) and titanium alloy(Ti-6Al-4V). Material and method : Cast titanium and its alloy rods(ISO6871) were prepared and perpendicularly cut at the center of the rod. After the cut halves were fixed in a jig, and the joints welded with a laser-welding machine at several levels of output voltage of $200V{\sim}280V$. Uncut specimens served as the non-welded control specimens The pulse duration and pulse spot size employed in this study were 10ms and 1.0mm respectively. Tensile testing was conducted at a crosshead speed of 0.5mm/min. The ultimate tensile strength(MPa) was recorded, and the data (n=6) were statistically analyzed by one-way analysis of variance(ANOVA) and Scheffe's test at ${\alpha}$=0.05. The fracture surface of specimens investigated by scanning electron microscope (SEM). Vickers microhardness was measured under 500g load of 15seconds with the optimal condition of output voltage 280V. Results : The results of this study were obtained as follows, 1. When the pulse duration and spot size were fixed at 10ms and 1.0mm respectively, increasing the output energy(voltage) increased UTS values and penetration depth of laser welded to titanium and titanium alloy. 2. For the commercial titanium grade II, ultimate tensile strength(665.3MPa) of the specimens laser-welded at voltage of 280V were not statistically(p>0.05) different from the non-welded control specimens (680.2MPa). 3. For the titanium alloy(Ti-6Al-4V), ultimate tensile strength(988.3MPa) of the specimens laser-welded at voltage of 280V were statistically(p<0.05) different from the non-welded control specimens (665.0MPa). 4. The commercial titanium grade II and titanium alloy(Ti-6Al-4V) were Vickers microhardness values were increased in the fusion zone and there were no significant differences in base metal, heat-affected zone.
본 연구는 우리나라 중규모 제조기업에서 전기전자, 기계 및 엔지니어링, 부품 소재산업을 모집단으로 하고 이들 모집단에서 전기전자 부문 12개 기업, 기계 및 엔지니어링 부문 18개 기업, 부품 소재 부문 16개 기업 등을 표본으로 선정하여 이들 표본기업의 기술경영의 실태를 분석하고 기술경영의 펙터가 신제품개발 성과에 미치는 영향을 분석하였다. 분석 결과 기술경영 펙터 중에 CTO를 비롯한 최고경영층의 기술경영에 대한 의지는 비교적 높게 나타났으나 그 외 사업전략과 기술전략의 연계성, 개방형 연구개발 시스템, 체계적 일정관리, 연구개발 인력관리, 제품수명주기관리 시스템 개발과 적용 등은 보통보다 조금 높은 수준인 것으로 나타난 점으로 볼 때 이들 각 분야에 대한 중요성의 인식과 더불어 보다 많은 노력을 강구하여야 할 필요성을 알 수 있다. 또한 가설검정 결과에서 이들 중규모 기업들이 신제품개발성과(신제품개발 기간 단축, 제품수명주기에 부합, 제품경쟁력 증대)를 높이기 위해서는 기술경영에 대한 최고경영층의 확고한 의지와 지원이 따라야 하고 사업전략과 기술전략의 연계성을 반드시 고려하여야 하며 신제품개발 일정관리를 체계적으로 하고 개방형 연구개발 시스템을 강화하며 연구개발 인력관리와 특히 PLM시스템 개발과 적용을 동시에 수행하여야 함을 알 수 있다.
본 논문은 수소를 연료로 하는 확산화염을 이용하여 알루미나 나노입자를 합성할 때, 합성되는 알루미나 나노입자의 특성에 미치는 화염온도의 영향을 조사하였다. 합성된 나노입자의 특성을 전자현미경 이미지, 결정구조 분석, 비표면적과 기공의 크기 분석, 화염온도 측정 등의 여러 특성분석 방법으로 조사하였다. 사용된 화염의 중심축 최고온도는 산화제의 산소농도가 19, 21, 30, 47%인 각각의 실험조건에서 1507.8K, 1593.8K, 1753.1K, 1998.7K으로 측정되었다. SEM 이미지 분석 및 BET 비표면적 측정을 통해서는 47% 산소농도인 경우에는 50 nm 수준의 독립적인 구형입자가 생성되었음을 확인할 수 있었으며, 19%와 21%의 경우에는 응집된 상태의 20-30 nm 수준의 입자를 볼 수 있었다. XRD 결과에서는 감마(${\gamma}$)-알루미나가 주를 이루는 것으로 판단되었다. 이상의 결과를 바탕으로 촉매 담체로 사용하기 위한 알루미나 나노입자를 연소합성 하기 위한 가장 적절한 조건으로 실험했던 네 경우 중에서는 산화제의 산소농도가 21%인 두 번째 경우를 선택할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.