MECHANICAL PROPERTIES OF LASER-WELDED CAST TITANIUM AND TITANIUM ALLOY

원심 주조된 타이타늄과 타이타늄 합금의 레이저 용접 특성

  • Yun, Mi-Kyung (Department of Prosthodontics, College of Dentistry, Chonnam National University) ;
  • Kim, Hyun-Seung (Department of Prosthodontics, College of Dentistry, Chonnam National University) ;
  • Yang, Hong-So (Department of Prosthodontics, College of Dentistry, Chonnam National University) ;
  • Vang, Mong-Sook (Department of Prosthodontics, College of Dentistry, Chonnam National University) ;
  • Park, Sang-Won (Department of Prosthodontics, College of Dentistry, Chonnam National University) ;
  • Park, Ha-Ok (Department of Prosthodontics, College of Dentistry, Chonnam National University) ;
  • Lee, Kwang-Min (School of Materials Science and Engineering, Chonnam National University)
  • 윤미경 (전남대학교 치과대학 치과보철학교실) ;
  • 김현승 (전남대학교 치과대학 치과보철학교실) ;
  • 양홍서 (전남대학교 치과대학 치과보철학교실) ;
  • 방몽숙 (전남대학교 치과대학 치과보철학교실) ;
  • 박상원 (전남대학교 치과대학 치과보철학교실) ;
  • 박하옥 (전남대학교 치과대학 치과보철학교실) ;
  • 이광민 (전남대학교 공과대학 신소재공학부)
  • Published : 2006.10.31

Abstract

Purpose : The purpose of this study was to investigate the effect of the output energy(voltage) of laser welding on the strength and properties of joint of cast titanium(CP Gr II) and titanium alloy(Ti-6Al-4V). Material and method : Cast titanium and its alloy rods(ISO6871) were prepared and perpendicularly cut at the center of the rod. After the cut halves were fixed in a jig, and the joints welded with a laser-welding machine at several levels of output voltage of $200V{\sim}280V$. Uncut specimens served as the non-welded control specimens The pulse duration and pulse spot size employed in this study were 10ms and 1.0mm respectively. Tensile testing was conducted at a crosshead speed of 0.5mm/min. The ultimate tensile strength(MPa) was recorded, and the data (n=6) were statistically analyzed by one-way analysis of variance(ANOVA) and Scheffe's test at ${\alpha}$=0.05. The fracture surface of specimens investigated by scanning electron microscope (SEM). Vickers microhardness was measured under 500g load of 15seconds with the optimal condition of output voltage 280V. Results : The results of this study were obtained as follows, 1. When the pulse duration and spot size were fixed at 10ms and 1.0mm respectively, increasing the output energy(voltage) increased UTS values and penetration depth of laser welded to titanium and titanium alloy. 2. For the commercial titanium grade II, ultimate tensile strength(665.3MPa) of the specimens laser-welded at voltage of 280V were not statistically(p>0.05) different from the non-welded control specimens (680.2MPa). 3. For the titanium alloy(Ti-6Al-4V), ultimate tensile strength(988.3MPa) of the specimens laser-welded at voltage of 280V were statistically(p<0.05) different from the non-welded control specimens (665.0MPa). 4. The commercial titanium grade II and titanium alloy(Ti-6Al-4V) were Vickers microhardness values were increased in the fusion zone and there were no significant differences in base metal, heat-affected zone.

Keywords

References

  1. Bannon BP, Mild EE, Titanium alloys in surgical implants. ASTM STP 796, Philadelphia, Pa. 1981:7
  2. Okazaki Y, Tateishi T, Kyo K, Ito Y. Effect of small quantity of oxygen nitrogen on mechanical properties new titanium alloys for medical implant. J Japan Inst Metals 1998:62:207
  3. Watanabe I, Topham DS. Tensile strength and elogation of laser-welded Ti and Ti-6Al-7Nb. J Biomed Mater Res Part B, Appl Biomater 2004:71:46-51
  4. Weber H. The clinical acceptance of dental nickel-chrome alloys. Int Dent J 1983:33:49-54
  5. Bruce GJ, Hall WB. Nickel hypersensitivityrelated periodontitis. Compend Contin Educ Dent 1995:16:178,180-4:Quiz 186
  6. Meyer E. Non-precious alloys for metalceramics. ZWR. 1988:97:774-81
  7. Boyer R, welsch G, Collings EW. Materials properties handbook -Titanium alloys. ASM 1994
  8. Taira M, Moser JB, Greener EH. Face coats for dental casting of titanium alloys. J Dent Res 1985:64:317
  9. Hamanaka H, Doi H, Yoneyama T, Okuno O. Dental casting of titanium and Ni-Ti alloys by a new casting machine. J Dent Res 1989:68:1529-1533 https://doi.org/10.1177/00220345890680111201
  10. Ida K. Dental application of titanium and its alloys. Dental Journal 1989:30:297
  11. Hruska AR. A novel method for vaccum casting titanium. Int J Prosthodont 1990:3:142-145
  12. Takahashi J, Kimura H, Lautenschlager EP, Lin JH, Moser JB, Greener EH. Casting pure titanium into commercial phosphate bonded $SiO_2$ investment molds. J Dent Res 1990:69:1800-1805 https://doi.org/10.1177/00220345900690120301
  13. Sunnerkrantz PA, Syverud M, Her H. Effect of casting atmosphere on the quality of Ticrowns. Scand J Dent Res 1990:98:268272
  14. Mueller HJ, Giuseppetti AA, Waterstrat RM. Phosphate-bonded investment materials for titanium casting. J Dent Res 1990:69:367
  15. Hruska AR, Borelli P. Quality criteria for pure titanium casting, laboratory soldering, intraoral welding, and a device to aid in making uncontaminated castings. J Prosthet Dent 1991:66:561-565 https://doi.org/10.1016/0022-3913(91)90524-Z
  16. Ida K, Tsutsumi S, Togaya T. Titanium or titanium alloys for dental casting. J Dent Res 1980:59:985
  17. Chern Lin JH, Moser JB, Taira M, Greener EH. Cu-Ti, Co-Ti and Ni-Ti systems : Corrosion and microhardness. Oral Rehabil 1990:17:383-93 https://doi.org/10.1111/j.1365-2842.1990.tb00023.x
  18. Riesgo O, Greener EH, Moser JB. Titanium alloys with dental porcelain. J Dent Res 1984:63:319
  19. Moser JB, Lin JH, Taira M, Greener EH. Development of dental Pd-Ni alloys. Dent Mater 1985:1:37-40 https://doi.org/10.1016/S0109-5641(85)80021-X
  20. Greener EH, Moser JB, Opp J, Szurgot K, Marker BC. Properties of centrifugally cast commercial Ti and Ti-6Al-4V. J Dent Res 1986:65:317
  21. Okuno O, Hamanaka H. Titanium and titanium alloy in dental use. Dental Journal 1989:30:317
  22. Lugowski SJ, Smith DC, McHugh AD, Loon V. Release of metal ions from dental implant materials in vivo: Determination of Al, Co, Cr, Mo, Ni, V and Ti in organ tissue. J Biomed Mater Res 1991:25:14431458
  23. Brunette DM, Tengvall P, Textor M, Thomsen P. Titanium in Medicine. 2001
  24. Henderson D. McCracken's removable partial prosthodontics. 7th ed., St. Louis, C. V. Mosby Co ., 1985
  25. Smith DC. Acrylic denture: Mechanical evaluation of midline fracture. Br Dent J 1961:110:257-267
  26. Lancaster JF. Metallurgy if welding. 5th ed. London : Chapman & Hall 1993 p.3855a,79-92b,157-8c
  27. Wee AG, Aquilino SA, Schneider RL. Strategies to achieve fit in implant prosthodontics : a review of the literature. Int J Prostho 1999:12:167-178
  28. Derand T. Porcelain bond to laser-welded titanium surface. Dent Mater 1995:11:93-95 https://doi.org/10.1016/0109-5641(95)80040-9
  29. Smith DL, Burnett AP, Gordon TE. Laser welding of gold alloy. J Dent Res 1972:51:161-167 https://doi.org/10.1177/00220345720510011101
  30. Apotheker H, Nishimura I, Seerattan C. Laser-welded vs soldered nonprecious alloy dental bridges: A comparative study. Lasers in Surgery and Medicine 1984:4:207-213 https://doi.org/10.1002/lsm.1900040213
  31. Rubenstein JE. Stereo laser-welded titanium implant frameworks : Clinical and laboratory procedures with a summary of 1-year clinical trials. J Prosthet Dent 1995:74:284-293 https://doi.org/10.1016/S0022-3913(05)80136-2
  32. Preston JD, Reisbick MH. Laser fusion of selected dental casting. J Dent Res 1975:54:232-238
  33. Gordon TE, Smith DL. Laser welding of prostheses-An initial report. J Prosthet Dent 1970:24:472-476 https://doi.org/10.1016/0022-3913(70)90087-9
  34. Bergendal B, Palmqvist S. Laser-welded titanium frameworks for fixed prostheses supported by osseointegrated implants : a 2year multicenter study report. Int J Oral Maxillofac Implant 1995:10:199-206
  35. Linden B, Jemt T. Fixed implant-supported prostheses with welded titanium frameworks. Int J Periodont Rest Dent 1992:12:177-183
  36. Dawes C. Laser welding. Cambridge : Abington Publishing Ltd., in association with The welding Institute. 1992
  37. Berg E, Wagnere WC, Davik G, Dootz ER. Mechanical properties of laser-welded cast and wrought titanium. J Prosthet Dent 1995:74:250-257 https://doi.org/10.1016/S0022-3913(05)80131-3
  38. Sjogren G, Andersson M, Bergman M. Laser welding of titanium in dentistry. Acta Odontol Scand 1988:46:247-253 https://doi.org/10.3109/00016358809004774
  39. Togaya T, Shinosaki T. Introduction to laser welding in density. Quint Dent Tech 1999:27:52-63
  40. Yamagishi T, Ito M, Oshida Y, Hashem A. Tensile strength and elongation of laserwelded titanium. J Dent Res 1993:72-131 https://doi.org/10.1177/00220345930720011101
  41. Chai T, Chou CK. Mechanical properties of laser-welded cast titanium joints under different conditions. J Prosthet Dent 1998:79:477-483 https://doi.org/10.1016/S0022-3913(98)70165-9
  42. Lee JJ, Kim KS, Ahn SG, Bae TS, Park CW. Mechanical properties of laser welded titanium joints. J Korean Res Soc Dent Mater 2003:30:147-152
  43. Togaya T, Shinosaki T, Hatano H. Application of laser welding for dental laboratory works, Optimization of laser beam parameters by laser joint strength tests. Quint Dent Tech 2002:Extra issue: 190-198
  44. Roggensack M, Walter MH, Boning KW. Studies on laser-and plasma -welded titanium. Dent Mater 1993:9:104-107 https://doi.org/10.1016/0109-5641(93)90084-4
  45. Taylor JC, Hondrum SO, Prasad A, Brodersen CA. Effects of joint configuration for the arc welding of cast Ti-6Al-4V alloy rods in argon. J Prosthet Dent 1998:79:291-297 https://doi.org/10.1016/S0022-3913(98)70240-9
  46. Nabalung DP, Nicholls JI. Laser welding of a cobalt-chromium removable partial denture alloy. J Prosthet Dent 1998:79:285-290 https://doi.org/10.1016/S0022-3913(98)70239-2
  47. Lee SY, Chang IT, Heo SJ, Yim SH. Mechanical properties of titanium connectors treated by various welding techniques. J Kor Acad Prostho 1999:37:545-565
  48. Song YG, Ha IS, Song KY. Tensile Strength of Laser Welded-Titanium and Gold Alloys. J Kor Acad Prostho 2000:38:200-213
  49. Kim JJ, Choi JK, Hong CP. Three Dimensional Prediction of Shrinkage Defects Considering Solidification Contraction. Kor Acad Indus Tech 1995:15:93