• Title/Summary/Keyword: machine

Search Result 24,492, Processing Time 0.053 seconds

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

The effect of heat to remove cement on implant titanium abutment and screw (시멘트 제거를 위해 가한 열이 임플란트 티타늄 지대주와 나사에 미치는 영향)

  • Yi, Hyo-Gyoung;Gil, Ki-Sung;Lee, Jung-Jin;Ahn, Seung-Geun;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.179-187
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effect of heat applied to disintegrate cement on the removal torque value and fracture strength of titanium abutment and abutment screw. Materials and methods: Implants, titanium abutments and abutment screws were prepared for each 20 piece. Implant abutments and screws were classified as the control group in which no heat was applied and the experimental group was heated in a vacuum furnace to $450^{\circ}C$ for 8 minutes and cooled in air. The abutments and screws were connected to the implants with 30 Ncm tightening torque at interval 10 minutes and the removal torque value was measured 15 minutes later. And the fracture strength of abutment screw was measured using universal testing machine. Results: The mean removal torque value was $27.84{\pm}1.07Ncm$ in the control group and $26.55{\pm}1.56Ncm$ in the experimental group and showed statistically significant difference (P < .05). The mean fracture strength was $731.47{\pm}39.46N$ in the control group and $768.58{\pm}46.73N$ in the experimental group and showed statistically no significant difference (P > .05). Conclusion: The heat applied for cement disintegration significantly reduced the removal torque value of the abutment screw and did not significantly affect fracture strength of the abutment screw. Therefore, in the case of applying heat to disintegrate cement it is necessary to separate the abutment screw or pay attention to the reuse of the heated screw. However further studies are needed to evaluate the clinical reuse of the heated screw.

ELASTIC CONSTANTS, SHEAR BOND STRENGTH OF TUNNEL RESTORATIVE MATERIALS AND MARGINAL RIDGE STRENGTH OF RESTORED TEETH (터널형 2급와동 충전재의 탄성계수와 전단결합강도 및 수복치의 변연융선 파절강도에 관한 연구)

  • Lee, Ka-Yean;Park, Yeong-Joon;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.746-763
    • /
    • 1996
  • An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.

  • PDF

A STUDY ON THE BONDING OF COMPOMER TO DECIDUOUS DENTIN (컴포머와 유치 상아질의 결합에 관한 연구)

  • Kim, Jee-Tae;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • The purpose of this study was to evaluate the bonding of compomer to deciduous dentin which is known to have been developed to improve the weak properties of glass ionomer cement and composite resin. 120 sound primary molars were used for the shear bond strength test and another 24 for the scanning electron microscopic evaluation. Each material was ailed into polyethylene mold attached to exposed dentinal surface($3{\times}4mm$ in diameter) of sample blocks. Shearbond strength was measured using Universal testing machine and data were analyzed statistically with Oneway-ANOVA and Scheffe test. Scanning electron microscopic observation was performed in order to evaluate the pattern of distribution and penetration of resin tags and hybrid layer. Compomer groups(II-V) showed significantly higher bond strength values than glass ionomer group(I)(p<.05). Etching-compomer groups(III, V) showed the significantly higher bond strength than non-etching compomer groups(II, IV)(p<.05), but slightly lower values than composite resin group(VI) with no statistically significant difference(p>.05). No significantly different bond strength was found between compomer groups of different bonding system(p>.05). Scanning electron micrographs showed more irregular distribution of short and thin resin tags in non-etching compomer groups(II, IV) whereas the more regular and intimate distribution of long and thick tags in etching compomer groups(III, V) and composite resin group(VI). The evaluation of hybrid layer also showed more regular formation of thicker layer in etching compomer groups(III, V). Based on the results of present study, the use of compomer as an esthetic restorative material for primary molars might be justified.

  • PDF

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

COMPARISON OF COMPRESSIVE STRENGTH AND SURFACE MICROHARDNESS BETWEEN FLOWABLE COMPOSITE RESIN AND GIOMER (유동성 자이오머와 복합 레진의 압축 강도 및 표면 미세 경도 비교)

  • Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.383-388
    • /
    • 2012
  • The aim of this study was to compare the compressive strength and the surface microhardness of Beautifil flow (Shofu, Kyoto, Japan) with $Filtek^{TM}$ Z350, Z350XT (3M ESPE, USA). Fifteen specimens from each material were fabricated for testing. Compressive strength was measured by using a universal testing machine at a crosshead speed of 1 mm/min. Surface microhardness values were measured by using Vickers hardness tester under 4.9 N load and 10 seconds dwelling time. The compressive strength of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $218.7{\pm}18.4$ MPa and Group 1 $Filtek^{TM}$ Z350 was $205.5{\pm}27.1$ MPa. Group 3 Beautifil flow F00 was $176.5{\pm}30.3$ MPa, and Group 4 Beautifil flow F10 was $173.4{\pm}26.2$ MPa. The compressive strength of Group 2 is higher than Group 3 and 4 (p < 0.05). The surface microhardness of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $39.1{\pm}2.1$ and Group 4 Beautifil flow F10 was $27.9{\pm}1.8$. And Group 3 Beautifil flow F00 was $23.1{\pm}1.1$, Group 1 $Filtek^{TM}$ Z350 was $20.4{\pm}0.9$. There was a statistical significant difference in surface microhardness between all groups (p < 0.05). In conclusion, the compressive strength of giomer was below the level of flowable composite resin. However, the surface microhardness of giomer is comparable to that of flowable composite resin. Giomer would be the good alternative to composite resin, if there is improvement of the compressive strength of giomer.

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

Design Evaluation Model Based on Consumer Values: Three-step Approach from Product Attributes, Perceived Attributes, to Consumer Values (소비자 가치기반 디자인 평가 모형: 제품 속성, 인지 속성, 소비자 가치의 3단계 접근)

  • Kim, Keon-Woo;Park, Do-Hyung
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.4
    • /
    • pp.57-76
    • /
    • 2017
  • Recently, consumer needs are diversifying as information technologies are evolving rapidly. A lot of IT devices such as smart phones and tablet PCs are launching following the trend of information technology. While IT devices focused on the technical advance and improvement a few years ago, the situation is changed now. There is no difference in functional aspects, so companies are trying to differentiate IT devices in terms of appearance design. Consumers also consider design as being a more important factor in the decision-making of smart phones. Smart phones have become a fashion items, revealing consumers' own characteristics and personality. As the design and appearance of the smartphone become important things, it is necessary to examine consumer values from the design and appearance of IT devices. Furthermore, it is crucial to clarify the mechanisms of consumers' design evaluation and develop the design evaluation model based on the mechanism. Since the influence of design gets continuously strong, various and many studies related to design were carried out. These studies can classify three main streams. The first stream focuses on the role of design from the perspective of marketing and communication. The second one is the studies to find out an effective and appealing design from the perspective of industrial design. The last one is to examine the consumer values created by a product design, which means consumers' perception or feeling when they look and feel it. These numerous studies somewhat have dealt with consumer values, but they do not include product attributes, or do not cover the whole process and mechanism from product attributes to consumer values. In this study, we try to develop the holistic design evaluation model based on consumer values based on three-step approach from product attributes, perceived attributes, to consumer values. Product attributes means the real and physical characteristics each smart phone has. They consist of bezel, length, width, thickness, weight and curvature. Perceived attributes are derived from consumers' perception on product attributes. We consider perceived size of device, perceived size of display, perceived thickness, perceived weight, perceived bezel (top - bottom / left - right side), perceived curvature of edge, perceived curvature of back side, gap of each part, perceived gloss and perceived screen ratio. They are factorized into six clusters named as 'Size,' 'Slimness,' 'No-Frame,' 'Roundness,' 'Screen Ratio,' and 'Looseness.' We conducted qualitative research to find out consumer values, which are categorized into two: look and feel values. We identified the values named as 'Silhouette,' 'Neatness,' 'Attractiveness,' 'Polishing,' 'Innovativeness,' 'Professionalism,' 'Intellectualness,' 'Individuality,' and 'Distinctiveness' in terms of look values. Also, we identifies 'Stability,' 'Comfortableness,' 'Grip,' 'Solidity,' 'Non-fragility,' and 'Smoothness' in terms of feel values. They are factorized into five key values: 'Sleek Value,' 'Professional Value,' 'Unique Value,' 'Comfortable Value,' and 'Solid Value.' Finally, we developed the holistic design evaluation model by analyzing each relationship from product attributes, perceived attributes, to consumer values. This study has several theoretical and practical contributions. First, we found consumer values in terms of design evaluation and implicit chain relationship from the objective and physical characteristics to the subjective and mental evaluation. That is, the model explains the mechanism of design evaluation in consumer minds. Second, we suggest a general design evaluation process from product attributes, perceived attributes to consumer values. It is an adaptable methodology not only smart phone but also other IT products. Practically, this model can support the decision-making when companies initiative new product development. It can help product designers focus on their capacities with limited resources. Moreover, if its model combined with machine learning collecting consumers' purchasing data, most preferred values, sales data, etc., it will be able to evolve intelligent design decision support system.

A Study of the Accidents of the Residents in a Rural Area (일개 보건진료소 사업 지역의 사고조사)

  • Kang, Pock-Soo;Lee, Kyeong-Soo;Kim, Seok-Beom;Kim, Chang-Yoon;Lee, Ok-Keum
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.174-184
    • /
    • 1991
  • To determine the incidence rate of accidents and its associated factors, a prospective survey was carried out in a rural area of a total of 1,360 residents for 1 year from January 1 to December 31, 1988 in Shin-am Ri, Jungdong Myun, Sangju Kun, Kyungpook Province. Data for accidents were collected by the community health practitioner who is working at Primary Health Post in Shin-am Ri. A total number of accident cases was 85 among 1,360 persons during one year study period, and annual incidence rate was 62.5 per 1,000 persons. The highest incidence rate of accident was observed in the age group of 30-39 was 179.8. The incidence rate of accident in male was 86.5 which was about 2 times that in female. In male, the highest incidence rate was seen in 30-39 age group and in female, 60-69 age group. The highest incidence rate of accident was observed in spring(29.4%) and summer(29.4%), and the lowest in fall(17.7%). The highest incidence rate of accident was observed in Friday(24.5%) by day of week, and between 9 a.m. to 12 a.m. by time zone. The most frequent use of medical facilities was Primary Health Post(51.8%) and the next was clinic(38.8%). Mean duration of treatment was 9.8 days. The accident occured in the room and kitchen(23.5%), in the yard and barn(23.5%), on the road(22.4%). and in the rice field and dry field(20.0%). The causes of accident were motor vehicle accident(20.0%), piercing or cutting(20.0%), collision or fighting(12.9%), and poisoning(11.8%) in order of frequency. The most common type of injury was open wound which was 43.5%. The most common tool of accident was farm machine which was 23.5%. The most common injuried part of body was extremity(55.3%).

  • PDF

Effect of Heat Treatment in Dried Lavers and Modified Processing (마른김에 대한 열처리 효과와 제조 공정 개선 시험)

  • Lee, Tae-Seek;Lee, Hee-Jung;Byun, Han-Seok;Kim, Ji-Hoe;Park, Mi-Jung;Park, Hi-Yun;Jung, Kyoo-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.6
    • /
    • pp.529-532
    • /
    • 2000
  • To establish a food safety of dried layer, heat treatment effect on the bacterial density of dried layers was investigated. And a modified process developing experiment for dried layer products using closing type drying oven was carried out. tittle bacterial density difference on the dried layer products were found before and after heat treatment at $90^{\circ}C$ for 6 hrs called Hwaip treatment having been used for long term storage. Direct or indirect heat treatment of dried lavers using gas burner and frying pan reduced about 1 to 3 log cycle of viable cell count from $10^8\;CFU/g\;to\;10^5\;CFU/g$. Heat treatment by direct surface contact type cooking machine being used in the market place for cooked dried layer products could reduce the viable cell count on the layer product from $2.2{\times}10^5{\~}5.2{\times}10^7\;CFU/g\;to\;7.0{\times}10^2{\~}5.0{\times}10^5\;CFU/g$, Ultraviolet irradiation (20 W, 30 cm) to one or both side of the dried laver products reduced the viable cell count from $2.2{\times}10^6\;CFU/g\;to\;8.0{\times}10^5\;CFU/g\;and\;2.0{\times}10^5\;CFU/g$, respectively. The viable cell count of the dried layer products produced by modified process using a closing type dryer was about $10^3\;CFU/g$ and lower 3 log cycle than that in the products collected in market place and made by open type dryer.

  • PDF