• 제목/요약/키워드: m Method

검색결과 27,045건 처리시간 0.05초

면진장치를 가지는 구조물의 등가점성감쇠비 산정 (Estimation of Equivalent Viscous Damping of Structure with Base Isolation Devices)

  • 김태호;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.359-366
    • /
    • 2002
  • Direct Integration method(D.I) and Mode Superposition method(M.S) are used widely in dynamic analysis method for structure with isolation devices. D.I is used firstly because it is consider to nonlinearity of isolation device. M.S is applied in elastic region, but it is difficult to apply M.S because coincidence with othogonality condition in the case of adding the damping of isolation device. In this study, the method for calculation of damping ratio of isolated structure is proposed, and proposed method is verified with analysis for example structure.

  • PDF

하천제방의 누수탐사 및 누수량 평가에 관한 연구 (A Stud on the Estimation of Leakage and the probing Leakage in the River Bank)

  • 김경수;조기태
    • 대한지하수환경학회지
    • /
    • 제6권4호
    • /
    • pp.213-217
    • /
    • 1999
  • 하천제방은 하천 수리 구조물 중 가장 중요한 구조물중의 하나이다. 하천제방의 붕괴는 재해발생의 직접적인 원인이 되기 때문에 하천제방의 내구성. 안정성은 중요한 요소이다. 제방붕괴의 원인은 홍수범람과 제방 누수를 둘 수 있다. 본 연구는 전기 비저항 탐사를 이용하여 제방누수를 탐사하고. 또 제방의 누수가 발생하였을 경우 weighted residual method를 이용하여 제방 누수량을 평가하였다. 본 연구의 대상유역은 섬진강 상류유역이며. 대상제방의 제원은 길이 300 m. 소단 2.0 m. 제방 폭 4.5 m. 높이 4 m 이다. 본 연구에서는 대상제방에서 전기 비저항 탐사를 이용하여 제방의 누수여부를 평가하였다. 그리고 누수가 발생하는 지점에서 weighted residual method를 이용하여 제방 누수량을 평가하였다. 그 결과 해당제방의 누수는 39~45 m. 80~90 m, 218~222 m. 214~250 m 지점에서 발생하였으며, 누수형상은 직사각형 및 다각형 등의 형상을 보였다. 그리고 이들 누수지점에서 누수량은 2.7$\times$$10^{-3}$ $\textrm{m}^3$/sec로 평가되었다.

  • PDF

R. E. M. 에 의한 벽식 PRE-CAST 구조물의 탄성해석 (Elastic Analysis of Pre-Cast Panel Structures By Rigid Element method)

  • 권택진;김승덕;김기철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.17-24
    • /
    • 1994
  • In the analysis pre-cast large panel structures, we can use the new discrete analyzing method to be consisted of rigid bodies. Because the pre-cast panels we still more rigid than the connection, the rigid element method is more efficient numerical method than F. E. M. The characteristics of R. E. M. is that strains in element are not occurred by external loadings and the deformation of the structures by external loadings is transmitted through springs around elements. In this study, we focus on the comparison of the results from the R. E. M. and the F. E. M. in order to establish the validity of the R. E. M. to analysis of pre-cast panel structures.

  • PDF

A Method for Separating Volterra Kernels of Nonlinear Systems by Use of Different Amplitude M-sequences

  • Harada, Hiroshi;Nishiyama, Eiji;Kashiwagi, Hiroshi;Yamaguchi, Teruo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.271-274
    • /
    • 1998
  • This paper describes a new method for separation of the Volterra kernels which are identified by use of M-sequence. One of the authors has proposed a method for identification of Volterra kernels of nonlinear systems using M-sequence and correlation technique. When M-sequence are applied to a nonlinear systems, the cross-correlation function between the input and the output of the nonlinear systems includes cross-sections of high-order Volterra kernels. However, if various order Volterra kernels exixt on the obtained cross-correlation function, it is difficult to separate the Volterra kernels. In this paper, the authors show that the magnitude of Volterra kernels is maginified by the amplitude of M-sequence according to the order of Volterra kernels. By use of this property, each order Volterra kernels is obtained by solving linear equations. Simulations are carried out for some nonlinear systems. The results show that Volterra kernels can be separated in each order successfully by the proposed method.

  • PDF

Effective determination of nicotine enantiomers from e-liquids and biological fluids by high performance liquid chromatography (HPLC) using dispersive liquid-liquid microextraction (DLLME)

  • Song, Seunghoon;Myung, Seung-Woon
    • 분석과학
    • /
    • 제34권4호
    • /
    • pp.180-190
    • /
    • 2021
  • This study compared the efficacy of chiral GC and chiral HPLC for the analysis of nicotine. To develop a suitable dispersive liquid-liquid microextraction (DLLME) method, the following parameters were optimized: pH, extraction solvent, dispersive solvent, type and quantity of salt, and laboratory temperature. The validation of the method was carried out by the established HPLC method. The LODs were 0.11 ㎍/mL and 0.17 ㎍/mL for the (S)- and (R)- enantiomers, respectively. The LOQs were 0.30 ㎍/mL and 0.44 ㎍/mL, respectively. The optimal calibration range was between 0.30-18 ㎍/mL and 0.44-4.40 ㎍/mL, respectively, and the correlation coefficient (r2) was 0.9978-0.9996. The intra-day accuracy was 79.9-110.6 %, and the intra-day precision was 1.3-12.0 %. The inter-day accuracy was 87.8-108.0 %, and the inter-day precision was 4.0-12.8 %. E-liquid and biological fluids (urine and saliva) were analyzed using the established method.

자탈형 콤바인의 예취작업법에 관한 연구 -혼합예취법을 중심으로 (제1보)- (Stuides on the Cutting Methods of the Self-feeding Type Combine -on the Mixed Cutting Method (1)-on the Mixed Cutting Method(I))

  • 최복연
    • 한국농공학회지
    • /
    • 제18권2호
    • /
    • pp.4096-4104
    • /
    • 1976
  • This experiment was carried out to investigate the efficient turning method which will be able to use every cutting methods, to calculate the width of the center field which must transpose from rotary cutting method to return cutting method, to investigate the effects of L/W and unit field on the operation efficiency. The results are summarized as follows: 1. In case of cutting in the outer field, the efficient turning method is the "$\alpha$" type turning method (half U-shaped turning method) at the first rotation, is the "$\beta$" type turning method (T-shaped turning method) at the second to fourth rotation. 2. In case of cutting in the inner field, the efficient turning method which takes the least turning time is the "a" type turning method ($\Delta$-shaped turning method). 3. The width of the center field (W') changes by the length-width ratio (L/W) and width (W), W' is 9.0m in case that L/W is 2.5 and W is 30m. 4. The larger L/W and area of unit field (A) become, the more operation efficiency (E) increases, and the limits that E is affected signicantly by L/W is 2 to 3.5 and A is within 5,000$m^2$. within 5,000$m^2$.

  • PDF

하도에서의 홍수추적 -수정 Muskingum-Cunge 방법- (Flood Routing on the River by Revised Muskingum-Cunge Method)

  • 홍종운
    • 한국농공학회지
    • /
    • 제21권1호
    • /
    • pp.13-23
    • /
    • 1979
  • The predictien of a design flood hydrograph at a particular site on a river may be based on the derivation of a discharge or stage hydrograph at an upstream section, together with a method to route this hydrograph along the rest of the river. In order to limit this investigation to cases where the assumption like uniform rainfall may be reasonably valid, the derivation of unit hydrographs has been limited to catchment with an area less than 500 km2. Consequently, flood routing methods provide a useful tool for the analysis of flooding in all but the smaller catchment, particularly where the shape of the hydrograph as well as the peak value is required. The author, therefore, will introduce here a flood routing method on the open channel with a peak discharge of the catchment area concerned. The importance of being able to route floods accurately is also reflected in the large number of flood routing method which have been developed since the year 1900. There are the modified puls method, Steinberg method, Goodrich method, Ekdahl method, Tatum's mean continuously Equation, wisler-Brater method, Muskingum, chung, and Muskingum-cunge (M-C) method and so on. The author will try to introduce a flood routing method which is revised Muskingum-cunge method. In calculating flood routing by the M-C method, whole variable parameters on the river were assumed to almost uniform values from the upstream to the downstream. In the results, the controlled flood rates at the 40km downstream on the river is appeared to decrease 22m$^3$/sec or 12 percent of the peak flood 170m$^3$/sec.

  • PDF

Verification of Two Least-Squares Methods for Estimating Center of Rotation Using Optical Marker Trajectory

  • Lee, Jung Keun
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.371-378
    • /
    • 2017
  • An accurate and robust estimation of center of rotation (CoR) using optical marker trajectory is crucial in human biomechanics. In this regard, the performances of the two prevailing least-squares methods, the Gamage and Lasenby (GL) method, and the Chang and Pollard (CP) method, are verified in this paper. While both methods are sphere-fitting approaches in closed form and require no tuning parameters, they have not been thoroughly verified by comparison of their estimation accuracies. Furthermore, while for both methods, results for stationary CoR locations are presented, cases for perturbed CoR locations have not been investigated for any of them. In this paper, the estimation performances of the GL method and CP method are investigated by varying the range of motion (RoM) and noise amount, for both stationary and perturbed CoR locations. The difference in the estimation performance according to the variation in the amount of noise and RoM was clearly shown for both methods. However, the CP method outperformed the GL method, as seen in results from both the simulated and the experimental data. Particularly, when the RoM is small, the GL method failed to estimate the appropriate CoR while the CP method reasonably maintained the accuracy. In addition, the CP method showed a considerably better predictability in CoR estimation for the perturbed CoR location data than the GL method. Accordingly, it may be concluded that the CP method is more suitable than the GL method for CoR estimation when RoM is limited and CoR location is perturbed.

An Analysis of Driving Property of a Reflective Electronic Display Fabricated by Using Filtering Method of Non-moving Particles

  • Kim, Young-Cho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권5호
    • /
    • pp.233-236
    • /
    • 2012
  • The driving properties of a particle-insertion method that filters non-moving particles are analyzed, by measuring its optical and electrical properties. An area that is occupied by the moved particles is proposed, as a desirable evaluation method for a reflective display. To compare the driving property of the particle-moving method with that of the reported simple particle-loading method, two panels are fabricated, according to the different particle-insertion methods, in the same panel condition, of which the width of ribs is $30{\mu}m$, the cell size is $220{\mu}m{\times}220{\mu}m$, the cell gap is $116-120{\mu}m$, the q/m value of the black particles is $+1.8{\mu}C/g$ and that for the white particles is $-4.3{\mu}C/g$. The particle-moving method has a filtering effect which excludes the non-moving particles, inserting only movable particles into the respective cell, so that a panel fabricated by the particle-moving method can drive most of the particles in a cell. Also, most of the particles move at the threshold voltage of 40 V, with enhanced reflectivity. The driving property is also verified by measurement of the occupation rate of the moved particles.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권5호
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.