• Title/Summary/Keyword: low-dose

Search Result 2,913, Processing Time 0.147 seconds

Bioavailabilities of Omeprazole Administered to Rats through Various Routes

  • Choi, Mi-Sook;Lee, Young-Hee;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • 제18권3호
    • /
    • pp.141-145
    • /
    • 1995
  • Omeprazole, a proton pump inhibitor, was given intravenously (iv), orally (po), intraperitoneally (ip), hepatoportalvenously (pv), and intrarectally (ir) to rats at a dose of 72mg/kg in order to investigate the bioavailability of the drug, The extent of bioavailabilities of omeprazole administered through pv, ip, po, and ir routes were 88.5, 79.4, 40,8, and 38.7%, respectively. Pharmacokinetic analysis in this study and literatures (Regardh et al., 1985 : Watanabe et al., 1994) implied significant dose-dependency in hepatic first-pass metabolism, clearance and distribution, and acidic degradation in gastric fluid. The high bioavailability from the pv administration (88.5%) means that only 11.5% of dose was extracted by the first-pass metabolism through the liver at this dose (72 mg/kg). The low bioavailability from the oral administration (40.8%) in spite of minor hepatic first-pass extraction indicates low transport of the drug from GI lumen to portal vein. From the literature (Pilbrant and Cederberg, 1985), acidic degradation in gastric fluid was considered to be the major cause of the low transport. Thus, enteric coating of oral preparations would enhance the oral bioavailability substantially. The bioavailability of the drug from the rectal route, in which acidic degradation and hepatic first-pass metabolism may not occur, was low (38.7%) but comparable to that from the oral route (40.8 %) indicating poor transport across the rectal membrane. In this case, addition of an appropriate absorption enhancer would improve the bioavailability. Rectal route seems to be an possible alternative to the conventional oral route for omeprazole administration.

  • PDF

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

쥐 심실에서 Digitalis Receptor Desensitization에 관한 연구 (Studies on Digitalis Receptor Desensitization in Rat Ventricle)

  • 이신웅;이정수;장태수
    • Biomolecules & Therapeutics
    • /
    • 제2권2호
    • /
    • pp.114-119
    • /
    • 1994
  • [$^3$H]Ouabain binding parameters ( $K_{D}$ and $B_{max}$) to control rat ventricular strips and Langendorff preparations which were not previously exposed to ouabain were compared with those to both preparations that had been first exposed to a complete ouabain dose range of dose-response curve (10$^{-8}$ to 10$^{4}$M). In rat ventricular strips and Langendorff perfused heart preparations, cumulative dose-response curves of ouabain revealed biphasic positive inotropic effects, a "low-dose" effect and a "high-dose" effect with E $d_{50}$ values of 0.5 $\mu$M and 35 $\mu$M ouabain, respectively. The "low-dose" effect in ventricular strip disappeared or was diminished significantly when the ouabain dose-response curve was repeated after the washout of the effects of the first dose-response curve, whereas there were no significant differences in the maximal "high-dose"effect in both exposures to oubain. However, both of the control and ouabain-preexposed Langendorff perfused hearts revealed the same low-dose effects. The $K_{D}$ value for [$^3$H] ouabain binding and the ouabain binding site concentration ( $B_{max}$) estimated by [$^3$H]ouabain displacement assay in control preparations were 230 nM and 2 pmol/mg protein, respectively. [$^3$H]Ouabain binding parameters were not changed by repeated exposure to high concentrations of ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site ($\alpha$$_2$isoform).).).).).

  • PDF

컴퓨터 단층촬영을 이용한 요로결석 검사에서 저선량 CT의 적용에 대한 유용성 평가 (Usability Evaluation of Applied Low-dose CT When Examining Urinary Calculus Using Computed Tomography)

  • 김현진;지태정
    • 한국콘텐츠학회논문지
    • /
    • 제17권6호
    • /
    • pp.81-85
    • /
    • 2017
  • 본 연구는 컴퓨터단층촬영을 이용한 요로결석 검사에서 저선량 CT(Low dose Computed Tomography) 프로토콜의 적용에 따른 유용성을 평가하였다. 연구대상은 2016년 6월-12월까지 부산지역 일개 의료기관을 내원한 비뇨기계 환자이며 연구에 이용된 프로토콜은 통계적 반복 재구성법(Adaptive Statistical Iterative Reconstruction, ASIR)을 50% 적용한 저선량 CT 프로토콜이다. 정량적 분석 결과 횡단면상(Axial image)의 신장의 관심 영역(region of image. ROI) 내 평균 화소 값과 표준편차는 복부촬영 프로토콜 $26.21{\pm}7.08$, 저선량 CT 프로토콜 $20.03{\pm}8.16$이며 관상면(Coronal imalge) 영상에서 신장의 관심영역 내 평균 화소 값과 표준편차는 복부촬영 프로토콜 $22.07{\pm}7.35$, 저선량 CT 프로토콜 $21.67{\pm}6.11$이었다. 정성적 분석결과 인공물에 대한 4명의 관찰자 평균값은 복부촬영 프로토콜 $19.14{\pm}0.36$, 저선량 CT 프로토콜 $19.17{\pm}0.43$이며 해상도 및 대조도의 평균값은 복부촬영 프로토콜 $19.35{\pm}0.70$, 저선량 CT 프로토콜 $19.29{\pm}0.58$이었다. 피폭선량 분석 결과 복부촬영 프로토콜의 CTDIvol 평균값은 18.02 mGy, DLP 평균값은 $887.51mGy{\cdot}cm$이며 저선량 CT 프로토콜 CTDIvol 평균값은 7.412 mGy, DLP 평균값은 $361.22mGy{\cdot}cm$이었다. 이로 인한 선량의 감소율은 각 58.82%, 59.29% 이었다.

X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가 (A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System)

  • 한동균;고신관;선종률;윤석환;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

저용량의 Haloperidol투여에 의해 유발된 백서 뇌내 Dopamine $D_2$양 수용체증식 (Proliferation of Dopamine $D_2$-Like Receptors after Treatment with Low Dose Haloperidol in Rat Brain)

  • 김황진;한규희
    • 생물정신의학
    • /
    • 제3권2호
    • /
    • pp.240-244
    • /
    • 1996
  • 흰쥐에 항정신병약물인 haloperidol을 장기간 투여한 뒤 줄무늬체와 후결절 조직에서의 DA $D_2$양 수용체의 변동에 대해 조사하였다. 약물투여군 4군에게 haloperidol을 각기 0.05, 0.15, 0.5, 1.5mg/kg/day이 되게끔 4주간 투여하였다. DA수용체의 변동은 [$^3H$]spiperone을 이용한 결합반응법을 통해 알아 보았다. 정상대조군에 비해 4주 동안 haloperidol을 투여받은 군 모두에서 줄무늬체에서의 DA 수용체의 최대 결합치가 증가한 것으로 나타났다. 기존의 연구에서 사용한 용량보다 대단히 낮은 0.05mg/kg/day을 투여받은 군 역시 유의한 증가를 보여 낮은 용량의 haloperidol이 DA계에 영향을 미치는 것을 알 수 있었다. 후결절조직의 최대결합치는 haloperidol투여군 모두에서 증가한 경향을 볼 수 있었으나 정상대조군에 비해 1.5mg/kg/day투여군에서 유의한 증가를 볼 수 있었다. 본 실혐의 결과로 미루어 낮은 용량의 haloperidol을 장기간 투여했을 때 뇌내 DA계에 수용체증식이 나타나며 항정신병 효과의 발현과도 관련성이 시사된다. 이러한 결과는 최근 거론되고 있는 항정신병약물의 저용량투여를 간접적으로 지지하는 것으로 생각되며 DA계의 연동을 알리는 다른 생물학적 지표와의 관련성을 살피면 흥미로운 결과를 얻을 것으로 기대된다.

  • PDF

저선량율 방사선 조사한 BALB/c 마우스에서의 영향평가 (Bioassay in BALB/c mice exposed to low dose rate radiation)

  • 김성대;공은지;배민지;양광모;김중선
    • Journal of Radiation Protection and Research
    • /
    • 제37권3호
    • /
    • pp.159-166
    • /
    • 2012
  • 본 연구는 저선량율 방사선에 의한 급성독성을 조사하기 위해 BALB/c 마우스에게 낮은 선량율에 방사선을 만성 노출 후 일반증상과 체중, 장기중량, 부검소견, 혈액 및 뇨 검사를 통해 독성유무를 관찰하였다. 각각 암 수 20마리 마우스는 각 5마리씩 4군으로 분류하고, 3.49 $mGy{\cdot}h^{-1}$의 저선량율 방사선을 정상대조군, 0.02, 0.2, 2 Gy를 각각 5.7시간, 2.4일, 24일 간 지속적으로 노출시키고 조사 후 1일에 마우스를 희생하여 독성을 평가하였다. 저선량율 방사선은 최고선량의 (2 Gy) 노출에도 사망률, 임상증상, 체중, 사료와 음수 섭취량, 뇨검사, 혈청 생화학에서 독성이 관찰되지 않았다. 하지만 고환, 난소, 자궁을 포함한 생식 장기는 방사선량 의존적으로 장기의 무게가 감소되었으나, 다른 장기의 무게 변화는 관찰되지 않았다. 모든 방사선 조사군에서 혈액학적인 부작용은 관찰되지 않았고, 단지 호중구수가 노출선량에 의존적으로 증가하였다. 이번 실험결과 마우스에서 저선량율 방사선 노출은 최고 선량인 2 Gy의 노출에 다른 부작용은 관찰되지 않았으나, 암컷 수컷의 생식장기에 무게 감소가 관찰되었다.

저에너지X선 영역에서 유리선량계의 preheat과 Non-preheat과의 시간에 따른 build up 특성에 관한 연구 (Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time)

  • 손진현;민정환;김기원;손순륭;임현수
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3412-3418
    • /
    • 2013
  • 본 논문은 유리선량계를 이용하여 장기간에 걸쳐 방사선의 누적선량측정 시 예비가열(preheat)과정을 수행한 선량값과 예비가열을 수행하지 않은(non-preheat)선량값을 30일간 시간에 따른 선량변화와 빌드업 특성을 비교 평가함을 목적으로 하였다. 저 선량의 0.1 mGy, 1 mGy, 5 mGy의 선량을 얻기 위해 진단용 발생장치 AccuRay-650R을 사용하였다. 관전압, 관전류 조건으로 각각의 10개 총 30개의 유리선량계 GD SC-1에 조사하여 장시간에 걸쳐 빌드업 특성을 비교하였다. 예비가열을 거치지 않은 저선량의 유리선량에서 초기 판독선량값은 조사된 선량값에 미치지 못하다가 시간이 지남에 따라 점차 조사된 선량값으로 증가하는 것으로 나타냈다. 이후 실험 종료 후 예비가열을 실시한 값과 차이를 보이지는 않았으며 통계적으로도 유의한 차이는 없었다(p>0.05). 예비가열을 거친 저선량의 유리선량에서 초기 판독선량은 조사된 선량값에 근접하였고 일정한 안정상태를 보인 후 15일이 경과한 이후 부터는 점차 증가하는 것으로 나타냈다. 결론적으로 앞서 보고된 유리선량계의 특성들은 고에너지영역의 고선량에서 유리선량계의 특성들에 관한 내용으로 본 논문에서는 저에너지를 사용해서 저 선량의 누적 선량을 장시간 측정하고자 하면 예비가열을 실시하지 않고 판독을 해도 무방할 것으로 판단 사료된다.

유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구 (A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter)

  • 노성진;김효진;김현;정동혁;손태건;김정기;양광모;남상희;강영록
    • Journal of Radiation Protection and Research
    • /
    • 제40권4호
    • /
    • pp.202-210
    • /
    • 2015
  • 저선량 조사는 낮은 선량을 지속적으로 장기간 조사시키기 때문에 조사되는 마우스들에 대한 선량분포를 정확히 알고 있어야만 한다. 본 연구는 저선량 방사선에 대한 생물학적 영향평가를 위하여 동남권원자력의학원 연구센터에 설치된 $^{137}Cs$ 조사장치에 대하여 마우스조사 실험 시 마우스에 원하고자 하는 선량을 전달하기 위한 방법에 대하여 연구를 수행하였다. 마우스에 원하고자 하는 정확한 선량을 전달하기 위하여 선원에 대하여 동일한 위치에 마우스 케이지 45개를 설치할 수 있는 아파트를 자체 개발하였으며, 개발된 마우스 아파트 시스템에 대한 선량평가를 하기 위하여 유리선량계(glass dosimeter)를 실험용 마우스 머리와 배에 삽입한 후 기존 조사 시스템과 자체 개발한 마우스 아파트 시스템에 대해 비교 선량평가를 수행하였다. 기존시스템의 조사방식에서 최대 42%의 선량차이를 보였으며 개발한 마우스 아파트 시스템은 6% 이내의 선량차이를 보였다. 본 연구를 통해 개발된 마우스 아파트를 활용한 저선량 방사선에 대한 생물학적 영향평가 연구는 전달하고자 하는 선량을 보다 정확하게 제공할 수 있으며, 생물학적 분석결과에 신뢰성을 확보할 수 있다.

저선량 ${\gamma}$선이 기냐 생산된 감자 소괴경의 휴면과 생에 미치는 효과 (Effect of Low Dose ${\gamma}$ Radiation on the Dormancy and Growth of in vitro Microtuvers of Potato(Solanum Tuberosum L.))

  • 김동희;백명화;전재흥;김재성
    • 환경생물
    • /
    • 제19권4호
    • /
    • pp.270-277
    • /
    • 2001
  • 저선량 ${\gamma}$선 조사가 기내 유기한 대지와 수미 감자 소괴경의 맹아율과 식물체 생장 및 생리활성에 미치는 효과 등을 알아보고자 감자 소괴경의 저장기간별로 ${\gamma}$선을 0.5${\sim}$30Gy 까지 조사하여 pot실험을 수행하였다. 감자 소괴경의 휴면과 생육에 대한 저선량 ${\gamma}$선 효과는 품종과 저장기간에 따라 다소 차이가 있었다. 대지 품종의 경우 대체로 2,4,8Gy에서 대조구에 비해 높은 맹아 출현율을 보였고, 온실 재배에서는 4,8,16Gy에서 비교적 양호한 생육과 수량 증가 효과를 보였다. 수미 품종에서의 맹아 출현은 2Gy와 4Gy에서 촉진되었고 0.5Gy와 4Gy에서 양호한 생육 및 수량을 보였다. 엽록소 함량은 저선량 ${\gamma}$선 조사구에서 대조구에 비해 뚜렷한 증가효과를 보이지 않았다. 이에 저선량 ${\gamma}$선이 감자의 휴면타파와 생육촉진에 효과가 있음을 확인할 수가 있었다.

  • PDF