Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time
![]() |
Son, Jin-Hyun
(Department of Biomedical Engineering, Chungnam National University)
Min, Jung-Whan (Department of Radiology, Shin-Gu University) Kim, Ki-Won (Department of Radiology, Shin-Gu University) Son, Soon-Yong (Department of Radiology, Asan Medical Center) Lim, Hyun-Soo (Department of Biomedical Engineering, Chungnam National University) |
1 | K. H. Son, et al., "The characteristic evaluation of high dose linearity, accumulation dose, energy dependency of glass dosimeter", Journal of Radiation Protection, pp. 66-67, 2009. |
2 | ICRP: 1990 Recommendations of the International Commission on Radiological Protection. Publication 60, Annals of the ICRP Vol. 21, No. 1-3, Pergamon Press, Oxford, 1991. |
3 | KFDA: 2012 Guideline on patient dose suggestion of general radiology, pp. 1-56, 2012. |
4 | K. R. Dong, et al., "A study on the effects of scattering dose on eyes and thyroid for panoramagra phy - Focus on TLD and PLD". The Journal of the Korea Contents Association, 7(1), pp. 1118-1123, 2009. |
5 | J. H. Choi, et al., "Comparison on the dosimetry of TLD and PLD by dose area product". The Journal of the Korea Contents Association, 12(3), pp. 244-250, 2012. DOI: http://dx.doi.org/10.5392/JKCA.2012.12.03.244 과학기술학회마을 DOI ScienceOn |
6 | Chang-Gyu. Kim, et al., "Measurement dose of Dental Panoramagraphy using a Radiophotoluminesce nt Glass Rod Detector", The Journal of the Korea Contents Association. v. 12 no, 6 pp. 2624-2628. 2011. |
7 | C. H. Kim, et al., "The evaluation of the radiation dose and the image quality during MDCT using Glass Rod Detector", The Journal of Digital Policy & Management. v.10 no,2 pp. 249-254. 2012. |
8 | J. H. Yun. et al., "Effective Dose Determination From CT Head & Neck Region". Journal of radiological science and technology. v.34 no.2 pp: 105-116. 2011. 과학기술학회마을 |
9 | W. H. Lee, et al., "Comparison on the dosimetry of TLD and OSLD used in nuclear medicine", The Journal of the Korea Contents Association, 12(12), pp. 329-334, 2012. DOI: http://dx.doi.org/10.5392/JKCA.2012.12.12.329 DOI ScienceOn |
10 | C. G. Kim, "Diagnosis X-ray exposure dose measuring device when pre-heat effect" KAIS Spring Conference pp. 380-382, 2013 |
11 | J. H. Son, et al., "Experimental Study with Respect to Dose Charactrristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657", Journal of radiological science and technology. v.35 no.2 pp: 119-124. 2012. |
12 | F. Araki, et al., "Measurements of gamma-knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diod detector", Med. Phys. 30, pp. 1976-1981, 2003. DOI: http://dx.doi.org/10.1118/1.1587451 DOI ScienceOn |
13 | M. Tsuda, et al., "A few remarks on photoluminescence dosimetry with high energy X-rays", Jpn. J. Med. 20, pp. 131-139, 2000. |
14 | Asahi Techno Glass Corporation, "Explanation material of RPL glass dosimeter: small element system", Tokyo, Japan, 2000 |
15 | J. E. Rah, D. O. Shin, J. Y. Hong, et al., "Study ofn Dosimetric Properties of Radiophoto luminescent Glass Rod Detector", J. Korea Asso. Radiat. Prot. 31(4), pp. 181-186, 2006. |
![]() |