• 제목/요약/키워드: low-K

검색결과 67,638건 처리시간 0.072초

극미소 부분방전 측정시스템의 설계 및 제작 (Design and Fabrication of an Ultra-low Partial Discharge Measurement System)

  • 서황동;송재용;문승보;길경석;권장우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

등외품 인삼(파삼)의 유산균 발효에 의한 저분자 진세노사이드 함량 증진 (Enhancement of Low Molecular Ginsenoside Contents in Low Quality Fresh Ginseng by Fermentation Process)

  • 최운용;이춘근;송치호;서용창;김지선;김보현;신대현;윤창순;임혜원;이현용
    • 한국약용작물학회지
    • /
    • 제20권2호
    • /
    • pp.117-123
    • /
    • 2012
  • This study compared the contents of low molecular ginsenoside according to fermentation process in low grade fresh ginseng. Low grade fresh ginseng was directly inoculated with a 24 h seed culture of $Bifidobacterium$ Longum B6., $Lactobacillus$ $casei$., and incubated at $36^{\circ}C$ for 72 h. $Bifidobacterium$ Longum B6 was specifically was found to show the best growth on $3,255{\times}10^6\;CFU/m{\ell}$ after 48 h of fermentation. The content of ginsenoside Rb1, Re and Rd were decreased with the fermentation but ginsenoside Rh2 and Rg2 increased after fermentation process. In the case of low molecular ginsenoside conversion yields were 56.07% of Rh2, 12.03% of Rg3 and 77.11% of Rg2, respectively. In addition, compound-K was irregular conversion yield as long as 72 h of fermentation. This results indicate that fermentation process could increase the low molecular ginsenoside in low grade fresh ginseng.

Mapping quantitative trait loci controlling low-temperature germinability in rice

  • Nguyen, Hoang Nam;Park, In-Kyu;Yeo, Sang-Min;Yun, Yeo-Tae;Ahn, Sang-Nag
    • 농업과학연구
    • /
    • 제39권4호
    • /
    • pp.477-482
    • /
    • 2012
  • Low-temperature germination is one of the major determinants for stable stand establishment in the rice direct seeding method in temperate regions and at high altitude areas. Quantitative trait loci (QTL) controlling low-temperature germinability in rice were identified using 96 introgression lines (ILs) derived from a cross between Oryza rufipogon and the Korean japonica cultivar, 'Hwaseongbyeo'. The germination rate at $15^{\circ}C$ was measured to represent low-temperature germination and used for QTL analysis. The germination rate at $15^{\circ}C$ for 7 days of Oryza rufipogon and Hwaseongbyeo was 93.3 and 28.7%, respectively, and that of progenies ranged from 0 to 48%. A linkage map was constructed using 135 simple sequence repeat (SSR) markers. Five putative QTLs associated with low-temperature germination were detected on chromosomes 1, 3, 4, 10 and 11. The QTL, qltg10 on chromosome 10 accounted for 19.2% of the total phenotypic variation for low-temperature germinability. Four additional QTL, accounted for 10.4 - 15.1% of the total phenotypic variation. The O. rufipogon alleles in all detected QTLs loci increased the low-temperature germination rate. No QTL associated with low temperature germinability has been detected near the qltg10 QTL in this study suggesting that qltg10 is a new QTL. The locus, qltg10 is of particular interest because of its independence from undesirable height and maturity effects. The DNA markers linked to the QTL for low temperature germinability would be useful in selecting lines with enhanced low temperature germinability in rice breeding program.

저전력 블루투스를 사용한 사용자 성향 분석 시스템 (Customer Preference Analysis System using Bluetooth Low Energy)

  • 뉴엔휴;박지선;치옥용;박산;장현준;홍성빈;김준오;조경은
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2017년도 춘계학술발표대회
    • /
    • pp.1073-1074
    • /
    • 2017
  • In this paper, we present a customer preference analysis system using the Bluetooth Low Energy technology. Compared to Classic Bluetooth, Bluetooth Low Energy provides considerably reduced power consumption, and cost, as well as some unique characteristics while maintaining a similar communication range. The customer preference analysis system collects nearby Bluetooth Low Energy devices using an Android mobile device via Bluetooth Low Energy. In addition, the system is capable of suggesting, and advertising products that are related to these Bluetooth Low Energy devices based on the name of their manufacturer. This feature aims to attract potential customers to purchase these products.

High thermoelectric performance and low thermal conductivity in K-doped SnSe polycrystalline compounds

  • Lin, Chan-Chieh;Ginting, Dianta;Kim, Gareoung;Ahn, Kyunghan;Rhyee, Jong-Soo
    • Current Applied Physics
    • /
    • 제18권12호
    • /
    • pp.1534-1539
    • /
    • 2018
  • SnSe single crystal showed a high thermoelectric zT of 2.6 at 923 K mainly due to an extremely low thermal conductivity $0.23W\;m^{-1}\;K^{-1}$. It has anisotropic crystal structure resulting in deterioration of thermoelectric performance in polycrystalline SnSe, providing a low zT of 0.6 and 0.8 for Ag and Na-doped SnSe, respectively. Here, we presented the thermoelectric properties on the K-doped $K_xSn_{1-x}Se$ (x = 0, 0.1, 0.3, 0.5, 1.5, and 2.0%) polycrystals, synthesized by a high-temperature melting and hot-press sintering with annealing process. The K-doping in SnSe efficiently enhances the hole carrier concentration without significant degradation of carrier mobility. We find that there exist widespread Se-rich precipitates, inducing strong phonon scattering and thus resulting in a very low thermal conductivity. Due to low thermal conductivity and moderate power factor, the $K_{0.001}Sn_{0.999}Se$ sample shows an exceptionally high zT of 1.11 at 823 K which is significantly enhanced value in polycrystalline compounds.

Low-temperature polycrystalline silicon level shifter using capacitive coupling for low-power operation

  • Chung, Hoon-Ju;Sin, Yong-Won;Cho, Bong-Rae
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.21-23
    • /
    • 2010
  • A new level shifter using low-temperature polycrystalline silicon (poly-Si) thin-film transistors (TFTs) for low-power applications is proposed. The proposed level shifter uses a capacitive-coupling effect and can reduce the power consumption owing to its no-short-circuit current. Its power saving over the conventional level shifter is 72% for a 3.3 V input and a 10 V output.

비파괴식 검사를 통한 선글라스의 품질에 관한 연구 (Properties of Sunglass Lenses by Non-Destructive Test for the Sunglass Standards)

  • 임용무;심문식;심현석;김상문
    • 한국안광학회지
    • /
    • 제6권1호
    • /
    • pp.125-131
    • /
    • 2001
  • 시중에서 시판되고 있는 완성품 선글라스를 고가형 23개, 저가형 55개를 대상으로 비파괴식 검사를 통하여 선글라스의 품질에 대한 분석을 행하였다. 선글라스렌즈의 일반적 광학성질은 규격을 대체적으로 만족할 정도였으며, 재질면에서 HIGH-type은 glass의 비율이 그리고 LOW-type은 Acrylate의 비율이 높았다. HIGH-type의 투과색은 무채색에 근접하였으나 LOW-type은 570 nm와 485 nm를 잊는 선상에 넓게 분포되었다. 렌즈 투과색의 자극순도의 규정을 벗어난 경우는 HIGH-type에서 7%, LOW-type에서 18%였다. UV/VIS cut-off는 HIGH-type의 경우에 350 nm, 380 nm, 400 nm를 초과하는 그룹으로 대별되었으며 LOW-type에서는 350 nm 이하 영역에 있는 경우가 6%에 달하였다. erythemal UV의 투과특성에 있어서 HIGH-type의 경우에는 모두 규격을 만족시켰으나 LOW-type의 경우에는 DIN 규격에서 최대 5개의 fail을 보였다. 또한 Near UV의 투과특성은 HIGH-type의 선글라스에서 더 많은 fail을 보였다. IR 투과특성에서는 LOW-type이 HIGH-type보다 열등한 특성을 보였다. 신호등 인지도의 경우에 HIGH-type은 모두 규격을 만족시켰지만 LOW-type은 21.8%가 만족시키지 못하였다. 대비감도 시력은 L의 증가와 함께 증가하였으며, 측정 거리의 감소와 함께 높아졌다. a와 b의 변화에 따른 대비감도 시력은 a-b 교점에 근접하는 경우 높은 값을 보였다. 선글라스 렌즈의 특성은 투과색, UV, IR, 신호등 가시도, 재질, 대비감도 시력 등의 종합적인 평가에 의해서 이뤄져야 하며 한가지 규격의 획일적 적용을 지양해야 한다. 비파괴식 선글라스 렌즈의 분석에 있어서 HIGH-type의 경우가 LOW-type에 비하여 종합적인 특성이 우수하였다.

  • PDF

만성 요통 환자의 통증, 지식 및 교육 요구 (Degrees of Low Back Pain, Knowledge of and Educational Needs for Low Back Pain in Patients with Chronic Low Back Pain)

  • 김성경;김희승;정성수
    • 근관절건강학회지
    • /
    • 제24권1호
    • /
    • pp.56-65
    • /
    • 2017
  • Purpose: The purposes of this study were to identify degrees of low back pain, knowledge of and educational needs for low back pain of patients with chronic low back pain and to investigate their relationships. Methods: Data were collected from questionnaires distributed to 83 patients with chronic low back pain at a hospital. Results: The low back pain score was $4.70{\pm}2.22$ out of 10. The degree of low back pain was a statistically significant difference according to gender, smoking, radiating pain and frequency and duration, daily life disturbance degree, sleep disturbance and depression. The knowledge score was 8.29 out of 13. The knowledge was a statistically significant difference according to smoking and degree of sleep disturbance. The educational needs score was 39.83 out of 50. The educational needs was a statistically significant difference according to age, duration of disease, radiating pain, standing time, depression, pain treatment experience, and treatment institutions. As the low back pain increased, the educational needs increased (r=.254, p=.021). There were no correlations between low back pain and knowledge (r=-.040, p=.720) and knowledge and educational needs (r=.061, p=.581). Conclusion: It is important to focus on items with statistically significant differences in pain, knowledge, and educational needs, and to select low knowledge and high educational needs items to develop a systematic education plan.

광대역 저지특성을 갖는 반파장 저역통과 여파기 설계 (Design of Half-Wavelength Low-PASS Filter with Wideband Rejection Characteristic)

  • 김영태;김영주;박준석;김형석;임재봉;조홍구
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2003년도 하계학술대회
    • /
    • pp.293-295
    • /
    • 2003
  • In this paper, planar harmonic rejection low-pass filter is proposed to effectively suppress spurious response in stop-band. For suppress the unwanted signal such as spurious and harmonics, we presented a new design method controlled the higher order modes. The proposed low-pass filter was shown to suppress the spurious response by more than $20{\sim}40dB$ compared with conventional microstrip low-pass filters. The filter is evaluated by experiment and simulation with good agreement and shown to have attractive properties such as wide stop band range and low insertion loss.

  • PDF

An Efficient MPEG-4 Video Codec using Low-power Architectural Engines

  • Bontae Koo;Park, Juhyun;Park, Seongmo;Kim, Seongmin;Nakwoong Eum
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1308-1311
    • /
    • 2002
  • We present a low-power MPEG-4 video codec chip capable of delivering high-quality video data in wireless multimedia applications. The discussion will focus on the architectural design techniques for implementing a high-performance video compression/decompression chip at low power architectures. The proposed MPEG-4 video codec can perform 30 frames/s of QCIF or 7.5 frame/s of CIF at 27MHz for 128k∼144kbps. By introducing the efficiently optimized Frame Memory Interface architecture, low power motion estimation and embedded ARM microprocessor and AMBA interface, the proposed MPEG-4 video codec has low power consumption for wireless multimedia applications such as IMT-2000.

  • PDF