• Title/Summary/Keyword: low temperature condition

Search Result 2,366, Processing Time 0.036 seconds

Effective Screening Condition for Low-Temperature Germinability of Rice (벼 저온발아성의 효율적 검정 조건)

  • Kang, Jong-Re;Lim, Sang-Jong;Kim, Soon-Chul;Ko, Mi-Suk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.6
    • /
    • pp.711-715
    • /
    • 1995
  • This study was carried out to determine the desirable screeing condition for low-temperature germinability of rice seeds. The germination test was performed with fifty rice varieties from three countries, mainly including the recent Korean rice cultivars. The analyzed result of germination test under three temperature conditions(13$^{\circ}C$, 16$^{\circ}C$, $25^{\circ}C$) pointed out that 11 days after seeding at 13$^{\circ}C$ was the most efficient testing condition for low-temperature germinability in terms of mean and variation in germination rate. Highly significant correlations were observed between germination rates of 11 days after seeding at 13$^{\circ}C$ and germination coefficients, average days of germination at 13 for 20 days. Low-temperature germinability were highly positively associated with days to heading or amylose content, but negatively correlated with grain width.

  • PDF

DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE (저온도차 모형 스털링 엔진의 최대출력 설계조건)

  • Jung, P.S.;Won, M.Y.;Kim, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

Low Temperature Properties of Exchange-biased Magnetic Tunnel Junction

  • Lee, K. I.;J. G. Ha;S. Y. Bae;K. H. Shin
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.325-326
    • /
    • 2000
  • Low temperature diagnosis was performed as a probe for the integrity of MTJ(Magnetic tunnel junction) process which is optimised for the given plasma oxidation condition. TMR ratio increased slowly with decreasing temperature than that expected from spin wave exitation theory〔1〕. Junction resistance (RJ) does not follow T$\^$-$\frac{1}{2}$/ law below 200 K, indicating another conduction path besides spin polarized tunneling is involved at low temperature. Temperature dependence of conductance dip and bias dependence of TMR with temperature are discussed, from which the quality of tunnel barrier and its formation process can be inferred.

  • PDF

On Cutting Characteristics Change of Low Temperature Cooling Tool -Cutting Characteristics of Cage Motor Rotor- (저온냉각공구의 절삭특성 변화 -모타 회전자의절삭특성-)

  • 김순채
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.37-43
    • /
    • 1995
  • The cutting process of cage motor rotor require high precision and good roughness, the surface roughness fo cutting face is very important factor with effect on the magnetic flux density of cage motor rotor. The paper describes a cause of decrease in the cutting force and roughness on low temperature cooling tool by means of analysis on the mechanism of force system at cutting condition and experimental findings. The main results as compared with the room temperature cutting are as follow : 1) The cutting resistance decreased due to low temperature cooling tool. 2) The surface roughness decreased due to low temperature cooling tool. 3) The low temperature cooling tool effected machinability of the cutting direction in machined surface. 4) The low temperature cooling decreased burr of corner in feed direction.

  • PDF

An Optimization of Aging Time for Low-Temperature Water-Gas Shift Over Cu-Zn-Al Catalyst (저온 수성가스 전이 반응용 Cu-Zn-Al 촉매의 숙성시간 최적화)

  • SHIM, JAE-OH;NA, HYUN-SUK;AHN, SEON-YONG;JANG, WON-JUN;ROH, HYUN-SEOG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.103-110
    • /
    • 2019
  • Cu-Zn-Al catalysts were prepared via co-precipitation method for low-temperature water-gas shift (LT-WGS) reaction under practical reaction condition. Aging time was systematically changed to find optimum point for LT-WGS under practical condition. The Cu-Zn-Al catalyst aged for 72 hours showed the highest CO conversion within low-temperature range as well as very stable catalytic activity for 200 hours despite the practical reaction condition.

A Study on the Characteristics of the Suspension Components of Rolling Stocks in the Very low Temperature (극한 온도에서의 철도차량용 현가부품의 특성연구)

  • Choi, Byoung-Il;Na, Hee-Seung;Jang, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • This study is a preview of characteristics of (1st/2nd) rubber suspension parts in low temperature, it will be researched before Trans Korean Railway and continental railway network connection. Rubber material characteristics are different to steel materials. Behavior of rubber material shows large deformation in hyper-elastic region. Moreover, added dashpot and low temperature condition shows various non-linear characteristics.

  • PDF

DEVELOPMENT OF AN AUTOMATIC ENVIRONMENTAL CONTROL SYSTEM FOR LOW TEMPERATURE STORAGE HOUSE USING INTERNET

  • Chung, H.;Yun, H.S.;Lee, W.O.;Lee, K.H.;Cho, Y.K.;Park, W.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.676-683
    • /
    • 2000
  • For high quality storage of agricultural products, temperature, humidity and gas conditions in a storage house should be controlled properly. But most of the low temperature storage house is depending on temperature control. This study aimed to develop an automatic control system for low temperature storage house that can control storage conditions such as temperature, humidity and $CO_2$ gas concentration. The developed system alarms the user, by telephone or beeper, when abnormal condition has occurred. The farmer can also monitor the inside condition of warehouse in his residence, by Internet. From the results of the performance test, the temperature and relative humidity in the warehouse is controlled within the range of ${\pm}0.5^{circ}C$ and ${\pm}2%$, respectively.

  • PDF

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

The Influence of Nutritional Condition of Rice Seedlings on the Rooting Capability at Low Temperature (수도묘의 영양조건이 저온시 활착에 미치는 영향)

  • 류인수;최돈향;황선웅;정영상
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.4
    • /
    • pp.362-365
    • /
    • 1984
  • Application of phosphate and silicate at the seed bed stage of rice seedlings was investigated to improve nutritional condition and rooting capability at low temperature. The amounts of applied phosphate were 15kg/10a with or without 200 kg/10a of silicate, and 30 kg/10a without silicate. Seeding dates were March 31, April 9 and April 19. The dry weight of the seedlings seeded earlier date under low temperature was lower than that of the seedlings seeded later dates. The application of phosphate and silicate increased the dry weight of newly developed roots after trasplanting, and increased the number of tillers. Therefore, heavy application of phosphate and silicate is recommendable to improve the predisposition of the rice seedlings grown under the low temperature condition for early transplanting.

  • PDF

Experimental research of Pressure-Volume-Temperature mass gauging method using instantaneous analysis under cryogenic homogeneous condition (순간 해석 기법을 이용한 PVT 잔량 측정법의 극저온 균일 온도 조건에서의 실험적 연구)

  • Seo, Man-Su;Jeong, Sang-Kwon;Jung, Young-Suk;Ku, Dong-Hun;Ji, Dong-Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.38-43
    • /
    • 2012
  • In the extreme conditions of launch vehicle in a space, such as cryogenic temperature and low-gravity environment, the mass gauging of remaining propellants becomes a difficult problem. Pressure-volume-temperature (PVT) method is one of the attractive mass gauging methods under low-gravity due to its simplicity and reliability. PVT gauging experiment with various mass flow rates of helium injection is carried out with the experimental apparatus creating cryogenic homogeneous condition as the condition of low-gravity. Experimental results are analyzed by a novel PVT gauging analysis method which considers all instantaneous changes of pressure and temperature in the ullage volume with small time intervals. It is observed that the gauging error from the novel PVT gauging analysis is -0.11% with 2 slpm mass flow rate of helium injection.