Browse > Article
http://dx.doi.org/10.9714/psac.2012.14.1.038

Experimental research of Pressure-Volume-Temperature mass gauging method using instantaneous analysis under cryogenic homogeneous condition  

Seo, Man-Su (KAIST 기계공학과)
Jeong, Sang-Kwon (KAIST 기계공학과)
Jung, Young-Suk (항공우주연구원)
Ku, Dong-Hun (KAIST 기계공학과)
Ji, Dong-Jin (KAIST 부속 한국과학영재고등학교)
Publication Information
Progress in Superconductivity and Cryogenics / v.14, no.1, 2012 , pp. 38-43 More about this Journal
Abstract
In the extreme conditions of launch vehicle in a space, such as cryogenic temperature and low-gravity environment, the mass gauging of remaining propellants becomes a difficult problem. Pressure-volume-temperature (PVT) method is one of the attractive mass gauging methods under low-gravity due to its simplicity and reliability. PVT gauging experiment with various mass flow rates of helium injection is carried out with the experimental apparatus creating cryogenic homogeneous condition as the condition of low-gravity. Experimental results are analyzed by a novel PVT gauging analysis method which considers all instantaneous changes of pressure and temperature in the ullage volume with small time intervals. It is observed that the gauging error from the novel PVT gauging analysis is -0.11% with 2 slpm mass flow rate of helium injection.
Keywords
Mass gauging; PVT mass gauging; low gravity; microgravity;
Citations & Related Records
연도 인용수 순위
  • Reference
1 F. T. Dodge, "Propellant mass guaging: Database of vehicle applications and research and development studies," NASA/CR-2008-215281, 2008.
2 C. H. Panzarella and M. Kassemi, "Self-pressurization of large spherical cryogenic tanks in space," Journal of Spacecraft and Rockets, vol. 42, pp. 299-308, 2005.   DOI   ScienceOn
3 M. V. Chobotov and G. P. Purohit, "Low-Gravity Propellant Gauging System for Accurate Predictions of Spacecraft End-of-Life," Journal of Spacecraft and Rockets, vol. 30, pp. 92-101, 1993.   DOI
4 N. T. Van Dresar, "PVT gauging with liquid nitrogen," Cryogenics, vol. 46, pp. 118-125, Feb-Mar 2006.   DOI   ScienceOn
5 M. Seo, et al., "Improved estimation of cryogenic liquid volume under low gravity condition," presented at the Space cryogenic workshop, Coeur D'Alene, Idaho, 2011.
6 N. T. Van Dresar, "An uncertainty analysis of the PVT gauging method applied to sub-critical cryogenic propellant tanks," Cryogenics, vol. 44, pp. 515-523, 2004.   DOI   ScienceOn