• Title/Summary/Keyword: low sample size

Search Result 453, Processing Time 0.034 seconds

Two-Stage Charge Equalization Scheme for Hybrid Electric Vehicle Lithium-Ion Battery Cells

  • Park, Hong-Sun;Kim, Chong-Eun;Moon, Gun-Woo;Lee, Joong-hui
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.241-243
    • /
    • 2007
  • Two-stage charge equalization scheme for HEV lithium-ion battery string is proposed with the optimal power rating design rule in this paper, where in the first stage the over charged energy of higher voltage cells is drawn out to the single common output capacitor and then, that discharged energy is recovered into the overall battery stack in the second stage. To achieve charge equalization of sort, the conventional flyback DC/DC converters of low power and minimized size are employed. The industrial sample employing both the proposed two-stage cell balancing scheme and the optimal power rating design rule shows good cell balancing performance with reduced size as well as low voltage stresses of the electronic devices.

  • PDF

Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process (치과 임플란트 고정체의 여러 가지 제조공정과정에 따른 표면특성)

  • Jeong, Yong-Hoon;Moon, Young-Pil;Lee, Chung-Hwan;Yu, Jin-Woo;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.

Survival Prognostic Factors of Male Breast Cancer in Southern Iran: a LASSO-Cox Regression Approach

  • Shahraki, Hadi Raeisi;Salehi, Alireza;Zare, Najaf
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6773-6777
    • /
    • 2015
  • We used to LASSO-Cox method for determining prognostic factors of male breast cancer survival and showed the superiority of this method compared to Cox proportional hazard model in low sample size setting. In order to identify and estimate exactly the relative hazard of the most important factors effective for the survival duration of male breast cancer, the LASSO-Cox method has been used. Our data includes the information of male breast cancer patients in Fars province, south of Iran, from 1989 to 2008. Cox proportional hazard and LASSO-Cox models were fitted for 20 classified variables. To reduce the impact of missing data, the multiple imputation method was used 20 times through the Markov chain Mont Carlo method and the results were combined with Rubin's rules. In 50 patients, the age at diagnosis was 59.6 (SD=12.8) years with a minimum of 34 and maximum of 84 years and the mean of survival time was 62 months. Three, 5 and 10 year survival were 92%, 77% and 26%, respectively. Using the LASSO-Cox method led to eliminating 8 low effect variables and also decreased the standard error by 2.5 to 7 times. The relative efficiency of LASSO-Cox method compared with the Cox proportional hazard method was calculated as 22.39. The19 years follow of male breast cancer patients show that the age, having a history of alcohol use, nipple discharge, laterality, histological grade and duration of symptoms were the most important variables that have played an effective role in the patient's survival. In such situations, estimating the coefficients by LASSO-Cox method will be more efficient than the Cox's proportional hazard method.

Study on the Fenton Reaction Condition for Evaluation of Chemical Durability of PEMFC Membrane (PEMFC 고분자막의 화학적 내구성 평가를 위한 Fenton 반응 조건에 관한 연구)

  • Oh, Sohyeong;Park, Jisang;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.49-53
    • /
    • 2021
  • The Fenton reaction is often used to evaluate the chemical durability of polymer membranes of Proton Exchange Membrane Fuel Cells (PEMFC). However, due to the violent reaction between hydrogen peroxide and iron ions, it is difficult to compare experimental data because of low reproducibility. In this study, we tried to find the reaction conditions to improve the reproducibility of the durability test of the membrane by the Fenton reaction. The hydrogen peroxide concentration was fixed at 30%, the iron ion concentration, temperature, stirring speed, and sample size were varied, and the fluorine ion concentration of the Nafion polymer membrane deteriorated by radicals was measured. When the iron ion concentration was increased or the membrane sample size was increased, and the reaction temperature was increased to 80 ℃, the experimental deviation increased, so an iron ion concentration of 10 ppm, a temperature of 70 ℃, and a sample size of 0.5 ㎠ were suitable.

Experimental human infection with Fibricola cratera (Trematoda: Neodiplostomidae)

  • Shoop, Wesley-L.
    • Parasites, Hosts and Diseases
    • /
    • v.27 no.4
    • /
    • pp.249-252
    • /
    • 1989
  • Fibricola cratera is a strigeoid trematode indigenous to North America that, heretofore, was known only to infect wild mammals. Herein, it is reported that an experimental inoculation of a human volunteer produced a patellt infection that lasted 40 months. Symptoms of epigastric discomfort, loose stools and flatulence occurred over the first year of infection and ameliorated thereafter. Eggs per gram of stool were low (${\leq}2$) throughout the course of infection and were not detected by the standard technique of formalin-ether concentration. To monitor infection, the entire stool sample was examined each month after sieving through No. 10 (pore size 2 mm) and 100 (pore size $145{\;}{\mu\textrm{m}}$) sieves and collecting eggs on a No. 325 (pore size $45{\;}{\mu\textrm{m}}$) sieve. This is the first report of a North American strigeoid trematode capable of maturing in a human and is only the second species of strigeoid known to do so. The other species is F. seoulensis which has been implicated in 26 human infections in Korea.

  • PDF

Effects of Strain Annealing Grain Size on the Magnetic Properties of Extra-Low Carbon Steel (극저탄소강판의 자성에 미치는 변형소둔 결정립도의 영향)

  • An, S.K.;Jeong, W.S.;Park, J.U.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.19 no.4
    • /
    • pp.208-218
    • /
    • 2006
  • The effects of the grain size on the magnetic properties in extra-low carbon steel after strain annealing were investigated. Two kinds of sample were prepared. One is the annealed sheet, which was annealed at $670^{\circ}C$ and $850^{\circ}C$ for various time periods after cold rolling. The other is the strain annealed sheet, which was temper rolled by 0.4% and subsequently strain annealed at the temperature ranging between $670^{\circ}C$ and $850^{\circ}C$ for various time periods. The grains after strain annealing became more coarse than those after primary annealing. The grains were coarsened due to the strain induced grain boundary migration (SIGM). It was found that the permeability tended to be increased and coercivity tended to be decreased with the increase of grain size. The optimum magnetic properties was achieved after strain annealing at $850^{\circ}C$ for 30 minites. Under this condition, the coercivity was measured to be 0.6 and the permeability was measured up to be 13000.

Scale effects on triaxial peak and residual strength of granite and preliminary PFC3D models

  • Xian, Estevez-Ventosa;Uxia, Castro-Filgueira;Manuel A., Gonzalez-Fernandez;Fernando, Garcia-Bastante;Diego, Mas-Ivars;Leandro R., Alejano
    • Geomechanics and Engineering
    • /
    • v.31 no.5
    • /
    • pp.461-476
    • /
    • 2022
  • Research studies on the scale effect on triaxial strength of intact rocks are scarce, being more common those in uniaxial strength. In this paper, the authors present and briefly interpret the peak and residual strength trends on a series of triaxial tests on different size specimens (30 mm to 84 mm diameter) of an intact granitic rock at confinements ranging from 0 to 15 MPa. Peak strength tends to grow from smaller to standard-size samples (54 mm) and then diminishes for larger values at low confinement. However, a slight change in strength is observed at higher confinements. Residual strength is observed to be much less size-dependent. Additionally, this study introduces preliminary modelling approaches of these laboratory observations with the help of three-dimensional particle flow code (PFC3D) simulations based on bonded particle models (BPM). Based on previous studies, two modelling approaches have been followed. In the first one, the maximum and minimum particle diameter (Dmax and Dmin) are kept constant irrespective of the sample size, whereas in the second one, the resolution (number of particles within the sample or ϕv) was kept constant. Neither of these approaches properly represent the observations in actual laboratory tests, even if both of them show some interesting capabilities reported in this document. Eventually, some suggestions are provided to proceed towards improving modelling approaches to represent observed scale effects.

Comparative Studies of Different Thermal Consolidation Techniques on Thermoelectric Properties of BiTeSe Alloy (BiTeSe 합금의 열적성형방법에 따른 열전특성)

  • Sharief, P.;Dharmaiah, P.;Lee, C.H.;Ahn, S.S.;Lee, S.H;Son, H.T;Hong, S.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.3
    • /
    • pp.126-134
    • /
    • 2018
  • In this research, we produced polycrystalline n-type $Bi_2Te_{2.7}Se_{0.3}$ powder using water atomization. To obtain full benefit through water atomized powder, we have implemented spark plasma sintering and hot extrusion for powder compaction. The microstructure and thermoelectric properties were investigated and compared. The average grain size of SPS and extruded bulks were 3.08 and $3.86{\mu}m$ respectively. The extruded material microstructure contains layered grains with less grain boundaries and its counter-part SPS displays dense packed grains with high grain boundaries. Among both bulks, extrusion sample exhibited high power factor (PF) of $2.96{\times}10^{-3}Wm^{-1}K^{-2}$ which is 38% higher than SPS ($2.14{\times}10^{-3}$) bulk sample. Due to variations in grain size and grain boundaries, the SPS bulk shows low thermal conductivity than extruded bulk. However, the extruded bulk sample exhibited a peak ZT of 0.69 at 400 K, which is 19% higher than SPS bulk sample, due to its higher power factor.

Evaluation of dispersion degree of nanoparticles in TiO2/epoxy resin nanocomposites

  • Nam, Ki-Woo;Moon, Chang-Kwon
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.338-344
    • /
    • 2014
  • The purpose of this study was to evaluate the dispersion degree of particles using a nanoindentation test for titanium oxide nanoparticles/epoxy resin nanocomposites. Thus, the effects of the particle size and weight fraction, dispersion agent, and position of the sample on the modulus and degree of particle dispersion in the nanocomposites were investigated. As a result, the dispersion degree of large particles was found to be better than that of smaller particles in composites. It could be found that the aggregation or agglomeration of small particles with large surface energy occurred more easily in nanocomposites because of the large specific surface area. The moduli of the upper side of the film-shaped sample obtained from a nanoindentation test were low scattering, while the values for the bottom side were high scattering. Thus, the dispersion situation of the nanoparticles on the upper side of film-shaped samples could be considered to be better than that for the bottom side. This could be concluded due to the non-uniform nanoparticle dispersion in the same sample. The modulus obtained from nanoindentation test increased slightly with the content of nanoparticles and increased with the indented depth for the same sample. The latter is presumably due to the increase in the accumulated particles facing the indenter with the indented depth. The nanoindentation test was found to be a useful method to evaluate the dispersion status of nanoparticles in nanocomposites.

Dielectric and piezoelectric characteristics of low temperature sintering PCW-PMN-PZT ceramics with amount of $Nb_2O_5$ addition ($Nb_2O_5$ 첨가에 따른 저온소결 PCW-PMN-PZT 세라믹스의 유전 및 압전 특성)

  • Lee, Sang-Ho;Chung, Kwang-Hyun;Lee, Duck-Chool;Yoo, Ju-Hyun;Jeong, Yeong-Ho;Ryu, Sung-Lim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.798-801
    • /
    • 2004
  • In this study, in order to develop low temperature sintering ultrasonic vibrator, PCW-PMN-PZT ceramics with the amount of $Nb_2O_5$ addition were manufactured. All of the fabricated sample showed pure pervoskite structure of tetragonal phase. With increasing the amount of $Nb_2O_5$ addition, mechanical quality factor Qm were increased up to 0.2wt%$Nb_2O_5$ addition and then decreased. And also, with increasing the amount of $Nb_2O_5$ addition, grain size, kp, density and dielectric constant were linearly decreased. At the 0.2wt% $Nb_2O_5$ addition composition ceramic, kp of 0.48, Qm of 2186, ${\varepsilon}r$ of 1219 were shown, respectively. Their values were suitable for ultrasonic vibrator application.

  • PDF