• Title/Summary/Keyword: low power circuit

Search Result 1,996, Processing Time 0.029 seconds

Safely Improving Method to Zero-Harmonics Current with 4-Pole Low Voltage Circuit Breaker Equipped N-phase Trip Device (4극 저압차단기 N상 Trip장치를 사용한 영상고조파 안전성 개선방안)

  • Ki, Che-Ouk;Kim, Ju-Chul;Choi, Chang-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.458-461
    • /
    • 2009
  • In 3-phase 4 wire system, appearance of the $3^{rd}$ harmonic current by increasing non-liner load is the one of causes overheating neutral wire of power line, and apparatus. So it is necessary to protect power-factor decreasing by the $3^{rd}$ harmonic, and electric power apparatus, and line safely, in this study, power system accidents caused by the $3^{rd}$ harmonic were investigated, then harmonic components analysis and unbalanced load analysis got accomplished. As result, we proposed the method to protect the power line and apparatus from over-current of neutral line by using the most economic 4-pole low voltage circuit breaker.

  • PDF

Implementation of Effective Wireless Power Transmission Circuit for Low Power System

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.846-849
    • /
    • 2018
  • Wireless power transfer (WPT) is the technology that enables the power to transmit electromagnetic field to an electrical load without the use of wires. There are two kinds of magnetic resonant coupling and inductive coupling ways transmitting from the source to the output load. Compared with microwave method for energy transfer over a long distance, the magnetic resonance method has the advantages of reducing the barrier of electromagnetic wave and enhancing the efficiency of power transmission. In this paper, the wireless power transfer circuit having a resonant frequency of 13.45 MHz for the low power system is studied, and the hardware implementation is accomplished to measure the power transmission efficiency for the distance between the transmitter and the receiver.

A Minimal Power Scheduling Algorithm for Low Power Circuit Design

  • Lin, Chi-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.212-215
    • /
    • 2002
  • In this paper, we present an intermediate representation CDFG(Control Data Flow Graph) and an efficient scheduling technique for low power circuit design. The proposed CDFG represents control flow, data dependency and such constraints as resource constraints and timing constraints. In the scheduling technique, the constraints are substituted by subgraphs, and then the number of subgraphs is minimized by using the inclusion and overlap relation efficiently. Also, iterative rescheduling process are performed in a minimum bound estimation, starting with the as soon as possible as scheduling result, so as to reduce the power consumption in low power design. The effectiveness of the proposed algorithm has been proven by the experiment with the benchmark examples.

  • PDF

Low-cost Single-Phase HAIf-bridge Active Power Filter with One Current Sensor (단일 전류센서를 갖는 저가의 단상 반브릿지 APF)

  • 김길동;신정렬;이우동;박현준;김희중
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.3
    • /
    • pp.173-179
    • /
    • 2004
  • This paper describes a low-cost single-phase active power filter, which consists of a half-bridge PWM inverter with a simple control circuit. In order to verify the performance of proposed active power filter, many computer simulations with EMTP codes and experimental works with a hardware prototype were done. Both results confirm that the proposed active power filter shows excellent performance to eliminate the harmonics generated in the single-phase non-linear load. The active power filter has advantage of low implementation cost and compact size, using a half-bridge inverter and a simple control circuit with only one current sensor. So, it can be fabricated as a plug-in type. This paper shows the necessity and a good possibility to apply such advantage to the electric railway system.

Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-Attenuation Circuit (개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험)

  • Lee, Sung-Min;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.495-499
    • /
    • 2012
  • Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

An I-V Circuit with Combined Compensation for Infrared Receiver Chip

  • Tian, Lei;Li, Qin-qin;Chang, Shu-juan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.875-880
    • /
    • 2018
  • This paper proposes a novel combined compensation structure in the infrared receiver chip. For the infrared communication chip, the current-voltage (I-V) convert circuit is crucial and important. The circuit is composed by the transimpedance amplifier (TIA) and the combined compensation structures. The TIA converts the incited photons into photocurrent. In order to amplify the photocurrent and avoid the saturation, the TIA uses the combined compensation circuit. This novel compensation structure has the low frequency compensation and high frequency compensation circuit. The low frequency compensation circuit rejects the low frequency photocurrent in the ambient light preventing the saturation. The high frequency compensation circuit raises the high frequency input impedance preserving the sensitivity to the signal of interest. This circuit was implemented in a $0.6{\mu}m$ BiCMOS process. Simulation of the proposed circuit is carried out in the Cadence software, with the 3V power supply, it achieves a low frequency photocurrent rejection and the gain keeps 109dB ranging from 10nA to $300{\mu}A$. The test result fits the simulation and all the results exploit the validity of the circuit.

A Design of Power Circuit and LCL Filter for Switching Mode PV Simulator (스위칭방식 PV Simulator의 전력회로와 LCL필터 설계)

  • Lee, Sung-Min;Yu, Tae-Sik;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.431-437
    • /
    • 2012
  • PV simulators are essential equipment for testing power conditioning systems (PCS) which are one of an important part in PV generator systems, for testing before shipment. High dynamic PV simulator is required since MPPT(Maximum Power Point Tracking) test procedure has been established by EN50530 regulation recently. Most high quality PV simulator prevailed in the market is linear type which however has low efficiency. This paper proposes design guide lines for the power stage and LCL type filter cooperating with a switching mode PV simulator that shows high efficiency and very low power consumption. Proposed theory is verified by experiment.

Analysis on the Short Circuit Current of a Low Voltage Direct Current(DC) Distribution System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 저전압 직류 배전 시스템의 단락 고장 전류 분석)

  • Ahn, Jae-Min;Jeon, Jeong-Chay;Lim, Young-Bae;Bae, Seok-Myeong;Byeon, Gil-Sung;Lee, Kyoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.473-476
    • /
    • 2010
  • In this paper, we analyzed the short circuit current of a low voltage direct current distribution system. For the analysis, we performed the modeling of the low voltage direct current distribution system with a 6-pulse three-phase thyristor rectifier using the PSCAD/EMTDC, surveyed impedance of sources, transformers and distribution lines to run a simulation. A result of the simulation is that short circuit currents of the direct current distribution system with the rectifier decreased due to a thyristor-ON-resistance(Ron). But in case of the low thyristor-ON resistance, output fault current of the rectifier increased over three-phase short circuit current of an AC power system without a rectifier by regular ratio of the rectifier. Because the output fault current of the rectifier can increase over interrupting the capacity of circuit breakers, studying short circuit currents of a low voltage direct current distribution system with a rectifier is necessary for introducing the direct current distribution systems.

A Study on Hight Efficiency Inverter Ballast using Microprocessor (마이크로프로세서를 사용한 고효율 인버터 안정기에 관한 연구)

  • ;鄭載倫
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.220-220
    • /
    • 1999
  • This paper describes the high efficiency inverter ballast circuit using very cheap microprocessor, which has been developed by the author. A variety of soft-switching techniques have been proposed to reduce the switching losses and EMI problems that occur with higher switching frequencies in switched inverter ballast. The inverter ballast circuit, which employs a temperature sensing circuits has been also proposed to improve starting performance of the fluorescent lamps. That is, the inverter ballast circuit, which employs a soft-starting circuit and soft-switching techniques to implement the power factor correction and to mitigate of power-loss and increase a life time of the fluorescent lamps, has become an attractive performance for ballasting the fluorescent lamps. In this paper, the operation and the control of the inverter ballast are described in detail and experimental results are presented. As the experimental results, when environment temperature is at -40℃, the inverter ballast circuit has low THD(4.8%) of the input current and large power factor(98%) of the lamp current. The proposed improved ballast circuit appears to be a good performance for ballasting fluorescent lamps.

Design and Implementation of L/Ku-band Broadband Power Detector using Schottky Diode (Schottky 다이오드를 이용한 Six-port용 L/Ku-band 광대역 Power detector 설계 제작)

  • Kim Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.615-618
    • /
    • 2006
  • The broadband power detector for direct- onversion Six-port output circuit was designed and implementaed in this paper. The power detector should linearly operated to produce the linear amplitude and phase signal fer input RF signal in required broadband. So, the power detector should be designed under conditions of matching circuit with low VSWR. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with matching circuit and isolator, respectively, were evaluated in the performances.

  • PDF