• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.026 seconds

Schottky Barrier Thin Film Transistor by using Platinum-silicided Source and Drain (플레티늄-실리사이드를 이용한 쇼트키 장벽 다결정 박막 트랜지스터)

  • Shin, Jin-Wook;Chung, Hong-Bay;Lee, Young-Hie;Cho, Won-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.462-465
    • /
    • 2009
  • Schottky barrier thin film transistors (SB-TFT) on polycrystalline silicon(poly-Si) are fabricated by platinum silicided source/drain for p-type SB-TFT. High quality poly-Si film were obtained by crystallizing the amorphous Si film with excimer laser annealing (ELA) or solid phase crystallization (SPC) method, The fabricated poly-Si SB-TFTs showed low leakage current level and a large on/off current ratio larger than 10), Significant improvement of electrical characteristics were obtained by the additional forming gas annealing in 2% $H_2/N_2$ ambient, which is attributed to the termination of dangling bond at the poly-Si grain boundaries as well as the reduction of interface trap states at gate oxide/poly-Si channel.

Safety Countermeasure of the distribution box of service wire (인입선 분기함의 안전대책에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.246-248
    • /
    • 2004
  • The lower voltage distribution box of service wire has been usually employed to supply an electric power to the consumers through low voltage overhead line. Now-a-days, electric shock accident at the distribution box of service wire installed in the seashore areas has been often occurred. The reason is mainly due to the electric leakage in the distribution box of service wire. This paper described insulation breakdown mechanism of distribution box of service wire, analysis of electric shock path and safety countermeasure of distribution box of service wire.

  • PDF

Clinical Study of St.Jude Medical Cardiac Valve (St.Jude Medical 판막의 임상성적)

  • Kim, Sang-Hyeong;Jang, Won-Chae
    • Journal of Chest Surgery
    • /
    • v.27 no.2
    • /
    • pp.114-121
    • /
    • 1994
  • St. Jude Medical cardiac valve replacement was performed in 135 consecutive patients from Aug.1986 to Dec. 1991.72 had mitral, 28 had aortic, 1 had tricuspid and 34 had double valve replacement. The hospital mortality rate was 4.4% & the late mortality rate was 3.7 %. Follow-up was done on 115 surviving patients:mean follow-up period was 29.78 $\pm$ 18.32 months. Paravalvular leakage was observed in two patients, possible prosthetic valvular endocarditis wasobserved in one patient and other specific valve-related complications were none. The overall actuarial survival rate at 6 years were 91.6% in total, 96.4% in aortic, 95.5 % in mitral and 81.9 % in double valve replacement.We concluded, therefore that good clinical results and a low complication rate could be achieved with St. Jude Medical valve in short-term follow-up & long-term follow-up was also necessary.

  • PDF

Finite Element Analysis of Power Steering Hose Subject to Internal Pressure (내압을 받는 파워스티어링 호스의 유한요소해석)

  • Cho, Jin-Rae;Jeon, Do-Hyung;Roh, Gi-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.181-188
    • /
    • 2004
  • The objective of this paper is to numerically examine the mechanical behavior of the swaged power steering(PS) hose subject to internal pressure. PS hose experiences a large internal pressure change in operating, so it's material part has to resist a cyclic expansion and compression without causing oil leakage. This cyclic pressure is intimately associated with fatigue failure of PS hose. In this study, we compare two types of PS hose. The numerical investigation is composed of three steps; swaging analysis, low and high pressure analyses. The comparative numerical results provide the basic data for the optimal PS design.

Characteristic analysis of RCD clamp for reducing voltage stress of Flyback converter (플라이백 컨버터의 전압 스트레스 저감을 위한 RCD클램프의 특성 분석)

  • Jeong, Jin-Woo;Lim, Jeong-Gyu;Chung, Se-Kyo;Kim, Jong-Hae;Oh, Dong-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.5-6
    • /
    • 2010
  • RCD clamp is used for a low cost flyback converter to clamp the voltage spikes caused by the leakage inductance of the flyback transformer. In this paper, the operational characteristics of the flyback converter with the clamp circuit are analyzed using an equivalent circuit. The simulation and experimental results are provided to verify the proposed analysis.

  • PDF

A Strategy for Kori Unit 1 Pressure Vessel Fluence Reduction through a Modification of Outer Assembly Configuration Using Monte Carlo Analysis

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Jong-Oh
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.515-519
    • /
    • 1997
  • The purpose of this study is to reduce the fast neutron fluence at the reactor pressure vessel(RPV) and to provide a basis for plant-life extension. In this study, different neutron absorbers were employed in the core outer assemblies of Kori Unit 1 Cycle 14. The modified assemblies were used to calculate fast neutron fluence at the RPV and to evaluate reduction of outer assembly power and total power in core. By comparison with the case of no suppression fixture, the fast neutron fluence of a case with two rows stainless steel around the assembly with natural uranium pins is decreased by 85.8%. It is noted that the modification of outer assembly is more efficient than the previous low leakage loading pattern (LLLP) applied to Kori Unit 1. Also, compared fast neutron fluence in Cycle 1 with Cycle 14, fast neutron fluence at the RPV between Cycle 1 and Cycle 14 is not significantly different. It is found that LLLP applied to the Kori Unit 1 has not contributed to fast neutron fluence reduction at the RPV.

  • PDF

High speed wide fan-in designs using clock controlled dual keeper domino logic circuits

  • Angeline, A. Anita;Bhaaskaran, V.S. Kanchana
    • ETRI Journal
    • /
    • v.41 no.3
    • /
    • pp.383-395
    • /
    • 2019
  • Clock Controlled Dual keeper Domino logic structures (CCDD_1 and CCDD_2) for achieving a high-speed performance with low power consumption and a good noise margin are proposed in this paper. The keeper control circuit comprises an additional PMOS keeper transistor controlled by the clock and foot node voltage. This control mechanism offers abrupt conditional control of the keeper circuit and reduces the contention current, leading to high-speed performance. The keeper transistor arrangement also reduces the loop gain associated with the feedback circuitry. Hence, the circuits offer less delay variability. The design and simulation of various wide fan-in designs using 180 nm CMOS technology validates the proposed CCDD_1 and CCDD_2 designs, offering an increased speed performance of 7.2% and 8.5%, respectively, over a conventional domino logic structure. The noise gain margin analysis proves good robustness of the CCDD structures when compared with a conventional domino logic circuit configuration. A Monte Carlo simulation for 2,000 runs under statistical process variations demonstrates that the proposed CCDD circuits offer a significantly reduced delay variability factor.

Balance Winding Scheme to Reduce Common-Mode Noise in Flyback Transformers

  • Fu, Kaining;Chen, Wei
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.296-306
    • /
    • 2019
  • The flyback topology is being widely used in power adapters. The coupling capacitance between primary and secondary windings of a flyback transformer is the main path for common-mode (CM) noise conduction. A Y-cap is usually used to effectively suppress EMI noise. However, this results in problems in space, cost, and the danger of safety leakage current. In this paper, the CM noise behaviors due to the electric field coupling of the transformer windings in a flyback adapter with synchronous rectification are analyzed. Then a scheme with balance winding is proposed to reduce the CM noise with a transformer winding design that eliminates the Y-cap. The planar transformer has advantages in terms of its low profile, good heat dissipation and good stray parameter consistency. Based on the proposed scheme, with the help of a full-wave simulation tool, the key parameter influences of the transformer PCB winding design on CM noise are further analyzed. Finally, a PCB transformer for an 18W adapter is designed and tested to verify the effectiveness of the balance winding scheme.

Establishment of Korea-China joint quality standards and improvement the performance of Non-hardening Waterproofing Material (비경화 방수재의 한·중 공동품질기준 마련 및 성능개선 연구)

  • Choi, Su-Young;An, Hyun-Ho;Choi, Young Hyun;Park, Wan-Goo;Kim, Dong-Bum;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.224-225
    • /
    • 2019
  • The purpose of this study was to develop a technology to prevent leakage of construction structures for the Chinese market. The first key development factor is to establish a joint quality standard that corresponds to all performance criteria set out in Chinese Standard JC / T 2428-2017. The second key development factor is to develop a product capable of exhibiting performance in a low temperature environment of $-30^{\circ}C$ and coping with 15mm structure behavior.

  • PDF

Optimum micro dimple configuration on the elastomer seal surface (탄성중합체 시일 표면의 미세 딤플에 대한 최적설계)

  • Yoo, Dae-Won
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.1-10
    • /
    • 2020
  • The seal plays a role in preventing oil leakage when the lip and the rotating shaft come into contact with the fluid and air pressure. Recently, micro dimples or micro pockets are processed and used on the lubrication surfaces of thrust bearings, mechanical bearings, and piston rings. Compared to a smooth surface, micro dimples reduce friction and increase the life of parts. This paper analyzed various kinds of micro dimple shapes on the sealing surface, i.e. circle, rectangle, triangle, and trapezoid. For this purpose, Introduced the design of experiments to work out a micro dimple configuration, unlikely to be damaged from cracks and low in contact stress. As a result, the triangular dimple showed the best results. Optimal factors were dimple size 0.15 mm, dimple depth 0.0383 mm, dimple density 40%, and the maximum equivalent stress was 9.1455 MPa, and the maximum contact pressure was 9.6612 MPa. This paper analyzed the optimal shape of dimples by finite element analysis. As a research project, experiments and comparative analysis of micro dimple shapes are needed.