• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.031 seconds

Electrical Properties of Organic Materials as Low Dielectric Constant Materials

  • Oh Teresa;Kim Hong Bae;Kwon Hak Yong;Son Jae Gu
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.67-72
    • /
    • 2005
  • The bonding structure of organic materials such as fluorinated amorphous carbon films was classified into two types due to the chemical shifts. The electrical properties of fluorinated amorphous carbon films also showed very different effect of two types notwithstanding a very little difference. Fluorinated amorphous carbon films with the cross-link breakage structure existed large leakage current resulting from effect of the electron tunneling. Increasing the cation due to the electron-deficient group increased the barrier height of the films with the cross-link amorphous structure, therefore the electric characteristic of the final materials with low dielectric constant was also improved. The lowest dielectric constant is 2.3 at the sample with the cross-link amorphous structure.

  • PDF

Modeling and Control of ISOP Active-Clamp-Forward Converter for xEV Low Voltage DC/DC Converter

  • Naradhipa, Adhistira M.;Kim, Byeongwoo;Kim, Kangsan;Cho, Woosik;Choi, Sewan;Huh, Dongyoung;Kim, Soohong;Cho, Kyungrae
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.99-101
    • /
    • 2018
  • This paper present an input-series output-parallel active-clamp-forward converter for low voltage dc/dc xEV application. The converter can achieve ZVS turn-on for all switches. An accurate small signal model of the converter which includes the effect of leakage inductance is given and controller design based on modeling is described. Experimental and simulation results from a 3.2kW, 100kHz prototype are presented in order to verify the validity of the converter operation and the designed control parameters.

  • PDF

3.5 inch QCIF AMOLED Panel with Ultra Low Temperature Polycrystalline Silicon Thin Film Transistor on Plastic Substrate

  • Kim, Yong-Hae;Chung, Choong-Heui;Moon, Jae-Hyun;Park, Dong-Jin;Lee, Su-Jae;Kim, Gi-Heon;Song, Yoon-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.717-720
    • /
    • 2007
  • We fabricated the 3.5 inch QCIF AMOLED panel with ultra low temperature polycrystalline silicon TFT on the plastic substrate. To reduce the leakage current, we used the triple layered gate metal structure. To reduce the stress from inorganic dielectric layer, we applied the organic interlayer dielectric and the photoactive insulating layer. By using the interlayer dielectric as a capacitor, the mask steps are reduced up to five.

  • PDF

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

Fabrication of TaOx Thin Film on Si-Substrate by Photo-CVD Method (광화학기상성장법에 의한 Si 기판상에서의 TaO$_{x}$ 박막 제작에 관한 연구)

  • 한봉명;김수용;김경식
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.3
    • /
    • pp.126-132
    • /
    • 1992
  • Recent VLSI requires materials with high dielectric constant in order to reduce their storage capacitor areas. Thin TaOx film was formed from Ta(OCH3)5 by photo-CVD method at a low temperature. The result shows that the film obtained by photo-CVD method is this study has good step coverage, high dielectric constant (20-25) and low leakage current. The high strong peaks from Ta(4f), Ta(4d), and O(ls) levels were observed by XPS analysis. From the diffraction pattern and TEM prcture analysis, the TaOx thin film was observed to be amorphous. This kind of the deposition method could be considered to be a very promising method applied to VLSI.

  • PDF

Development of rotor profile design technology for improving the screw compressor performance (공기압축기 성능향상을 위한 로터 프로파일 설계기술 개발 연구)

  • Kim, Tae-Yoon;Lee, Jae-Young;Lee, Dong-Kyun;Kim, Youn-Jea
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.585-592
    • /
    • 2009
  • The performance of screw compressor depends on lots of design parameters of rotor profile, such as length of seal line, wrap angle, blow hole, suction and discharge port size, number of rotor lobe, etc. The optimum rotor profile makes it possible to increase the compression efficiency with low energy consumption, and to minimize the loss of power. In this research, a new rotor profile design and performance analysis are done by computer simulation. It is expected that the volumetric efficiency is improved because the internal leakage is reduced due to the minimization of blow hole and clearance, and the stiffness of rotors is increased due to the reduction of length to diameter ratio. Also, the specific power consumption will be secured for use ranging from low to high operation speed.

  • PDF

Idling Performances of Reduction Gear Unit for Bimodal Tram (바이모달 트램용 감속기어장치의 무부하 성능평가)

  • Kim, Y.S.;Mok, J.K.;Chang, S.K.;Hong, Y.K.;Kim, Y.K.;Kim, J.W.;Kim, T.H.
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.584-589
    • /
    • 2008
  • A bi-modal tram has been developing to consist of articulated-two cars propelled by CNG hybrid (series type) in Korea since 2003. All wheels are driven by electrical motors independently, which can eliminate differential gears to reduce turning radius and make low floor to provide the old and the handicapped with easy access. In the bi-modal tram, therefore, reduction gear unit is key technology to make low floor and drive wheels independently. This study was aimed at performance evaluations of the reduction gear unit for the bi-modal tram. Oil leakage, oil temperature, vibration, acoustic noise in idle operations were measured for the reduction gear unit of the bimodal tram.

  • PDF

A Study on the Development of Early Acetone Gas Detection to Prevent the Acetone Leakage Accident (아세톤 누출사고 예방을 위한 아세톤 가스 조기감지 기술개발에 관한 연구)

  • Seung Jin Jeon;Youngbo Choi
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.30-35
    • /
    • 2023
  • Acetone is a widely used Volatile Organic Compound (VOC) in industries and laboratories. However, acetone affects human health adversely and causes fires and explosions. Early acetone detection and improved personnel training in safety and emergency management are necessary to prevent acetone-related accidents. The multi-VOC acetone detectors used currently have a sensitivity and selectivity limit. In this study, we discovered that Pt-loaded iron oxide (a metal oxide semiconductor) conversely, has high detection and selectivity for very low-levels of acetone gas. The loaded Pt catalyzes the reaction between the sensing materials' surface and the oxygen molecules in the air; this optimizes acetone detection and can decrease acetone-related illnesses, fires and explosions.

Outcomes Based on Risk Assessment of Anastomotic Leakage after Rectal Cancer Surgery

  • Gong, Jian-Ping;Yang, Liu;Huang, Xin-En;Sun, Bei-Cheng;Zhou, Jian-Nong;Yu, Dong-Sheng;Zhou, Xin;Li, Dong-Zheng;Guan, Xin;Wang, Dong-Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.707-712
    • /
    • 2014
  • Purpose: Anastomotic leakage (AL) is associated with high morbidity and mortality, high reoperation rates, and increased hospital length of stay. Here we investigated the risk factors for AL after anterior resection for rectal cancer with a double stapling technique. Patients and Methods: Data for 460 patients who underwent primary anterior resection with a double stapling technique for rectal carcinoma at a single institution from 2003 to 2007 were prospectively collected. All patients experienced a total mesorectal excision (TME) operation. Clinical AL was defined as the presence of leakage signs and confirmed by diagnostic work-up according to ICD-9 codes 997.4, 567.22 (abdominopelvic abscess), and 569.81 (fistula of the intestine). Univariate and logistic regression analyses of 20 variables were undertaken to determine risk factors for AL. Survival was analysed using the Cox regression method. Results: AL was noted in 35 (7.6%) of 460 patients with rectal cancer. :Median age of the patients was 65 (50-74) and 161 (35%) were male. The diagnosis of AL was made between the 6th and 12th postoperative day (POD; mean 8th POD). After univariate and multivariate analysis, age (p=0.004), gender (p=0.007), tumor site (p<0.001), preoperative body mass index (EMI) (p<0.001), the reduction of TSGF on 5th POD less than 10U/ml (p=0.044) and the pH value of pelvic dranage less than or equal to 6.978 on 3rd POD (p<0.001) were selected as 6 independent risk factors for AL. It was shown that significant differences in survival of the patients were AL-related (p<0.001), high ASA score related (p=0.036), high-level EMI related (p=0.007) and advanced TNM stage related

Applicability of the Multi-Channel Surface-soil CO2-concentration Monitoring (SCM) System as a Surface Soil CO2 Monitoring Tool (다채널 지표토양 CO2 농도 모니터링(SCM) 시스템 개발 및 적용성 평가 연구)

  • Sung, Ki-Sung;Yu, Soonyoung;Choi, Byoung-Young;Park, Jinyoung;Han, Raehee;Kim, Jeong-Chan;Park, Kwon Gyu;Chae, Gitak
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.41-55
    • /
    • 2015
  • Monitoring of $CO_2$ release through the ground surface is essential to confirm the safety of carbon storage projects. We conducted a feasibility study of the multi-channel surface-soil $CO_2$-concentration monitoring (SCM) system as a soil $CO_2$ monitoring tool with a small scale injection test. The background concentrations showed the distinct diurnal variation. The negative relation of $CO_2$ with temperature and the low $CO_2$ concentrations during the day imply that surface-soil $CO_2$ depends on photosynthesis and respiration. After 4.2 kg of $CO_2$ injection (1 m depth for 29 minutes), surface-soil $CO_2$ concentrations increased in the all five chambers, which were located less than 2.8 m of distance from each other. The $CO_2$ concentrations seem to be recovered to the background around 4 hours after the injection ended. To determine the leakage, the data from Chamber 2 and 5 with low increase rates were used for statistical analyses. Coefficient of variation for 30 minutes ($CV_{30min}$.) is efficient to determine a leakage signal, with reflecting the fast change in $CO_2$ concentrations. Consequently, SCM and $CV_{30min}$ could be applied for an efficient monitoring tool to detect $CO_2$ release through the ground surface. Also, this study provides ideas for establishing action steps after leakage detection.