• Title/Summary/Keyword: low frequency inverter

Search Result 397, Processing Time 0.031 seconds

Operation Characteristic of Transless type Grid-connected Inverter using Multi-level Switching circuit (멀티레벨 스위칭 회로를 이용한 트렌스리스형 계통 연계 인버터의 동작 특성)

  • Kim, Ju-Yong;No, Kwae-Hyeop;Jung, Tae-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.916-917
    • /
    • 2008
  • In this paper, Switching damage of switches that is used to proposed power conversion system is reduced by soft switching way. dissipation by part resonance and my resonance stress for resonance of resonance circuit are decreased. Is acted by conversion system high effectiveness. Have following characteristic. Design snubber circuit that is used by switch protection in existent hard work rate Topology by resonant circuit for sogt switching, circuit structure was simple and control system is easy. Also, Can generate free output voltage by multi level Tuesday of output that use individuation Power Cell's Phase Shift PWM, and Low-end switching frequency the harmonic is few.

  • PDF

Controller Design and Dynamic Performance Analysis of UPFC based on 3-Level Inverters (3-레벨 인버터 UPFC의 제어기설계와 동특성해석)

  • Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.272-279
    • /
    • 2000
  • This paper describes a controller design and dynamic performance analysis of UPFC based on 3-level inverters. Major attention is focused on the controller design for both shunt and series inverters, including regulator design for the dc link voltage sharing across the dc capacitors. An energy-based approach was investigated for effectively designing the controller. A detailed UPFC model has been developed with EMTP using 24-pulse 3-level inverters to verify this approach. Simulation results about dynamic performance of UPFC confirm effects for increasing transmission capacity and damping low-frequency oscillation. The developed simulation model would be very effective to analyze the dynamic performance of UPFC.

  • PDF

Speed Sensorless Control of Induction Motors in the Very Low Speed Region Considering the Secondary Resistance Identification using Flux Signal (자속정보를 이용한 2차저항 동정기능을 갖는 유도전동기의 저속영역 속도센서리스 제어)

  • Lee, Z.G.;Jeong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.308-310
    • /
    • 2001
  • This paper investigates a novel speed sensorless control method of I.M considering the secondary resistance identification based on the transientless torque control technique. Especially, this paper aimed at the identification of the secondary resistance simultaneously with speed estimation superposing of sinusoidal flux wave to a constant flux value. Furthermore, the secondary flux with some frequency is controlled independently on torque control. The proposed speed estimation method is derived from a motor circuit equation theoretically and also it can be conducted easily by detecting primary motor currents and primary voltage commands at every sampling time. Some numerical simulations with the assumption of using a pulse width modulation(PWM) voltage source inverter are performed to verify the proposed method.

  • PDF

Failure Prediction Monitoring of DC Electrolytic Capacitors in Half-bridge Boost Converter (단상 하프-브리지 부스트 컨버터에서 DC 전해 커패시터의 고장예측 모니터링)

  • Seo, Jang-Soo;Shon, Jin-Geun;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.345-350
    • /
    • 2014
  • DC electrolytic capacitor is widely used in the power converter including PWM inverter, switching power supply and PFC Boost converter system because of its large capacitance, small size and low cost. In this paper, basic characteristics of DC electrolytic capacitor vs. frequency is presented and the real-time estimation scheme of ESR and capacitance based on the bandpass filtering is adopted to the single phase boost converter of uninterruptible power supply to diagnose its split dc-link capacitors. The feasibility of this real-time failure prediction monitoring system is verified by the computer simulation of the 5[kW] singe phase PFC half-bridge boost converter.

Register Controlled Delay-locked Loop using Delay Monitor Scheme (Delay Monitor Scheme을 사용한 Register Controlled Delay-locked Loop)

  • 이광희;노주영;손상희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.2
    • /
    • pp.144-149
    • /
    • 2004
  • Register Controlled DLL with fast locking and low-power consumption, is described in this paper. Delay monitor scheme is proposed to achieve the fast locking and inverter is inserted in front of delay line to reduce the power consumption, also. Proposed DLL was fabricated in a 0.6${\mu}{\textrm}{m}$ 1-poly 3-metal CMOS technology. The proposed delay monitor scheme enables the DLL to lock to the external clock within 4 cycles. The power consumption is 36㎽ with 3V supply voltage at 34MHz clock frequency.

Speed Sensorless Control of Induction Motors in the Very Low Speed Region Considering the Secondary Resistance Identification (2차 저항 동정을 고려한 유도전동기의 저속영역 속도센서리스 제어)

  • Hwang, D.I.;Jeong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1042-1045
    • /
    • 2000
  • Speed control without speed sensor is expected strongly to progress reliability, simplicity and cost performance of I.M and to expand its application part. This paper investigates a novel speed estimation method of I.M considering the secondary resistance identification based on the transientless torque control technique. Especially, this paper aimed at the identification of the secondary resistance simultaneously with speed estimation. For this, the secondary flux with some frequency is controlled independently on torque. The proposed speed estimation method is derived from a motor circuit equation theoretically and also it can be conducted easily by detecting primary motor currents and primary voltage commands at every sampling time. Some numerical simulations with the assumption of using a pulse width modulation(PWM) voltage source inverter and experimental results are performed to verify the proposed method.

  • PDF

A Study on the 3kW Fuel Cell Generation System (3kW급 연료전지 발전시스템에 관한 연구)

  • Jeong, Dong-Hyo;Park, Jae-Se
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.75-78
    • /
    • 2005
  • Fuel cell is remarkable for one of the clean energy recently. But in the fuel cell case, it has characteristics with low voltage and high current. Therefore, for using domestic power, it should be changed to the power source with commercial voltage and frequency. In this paper fuel cell simulator having electrical characteristics is designed and constructed instead of fuel cell stack. Voltage generated from fuel cell is from 39V to 72V dc and should be boosted to 400V dc for home appliances. A stand alone system including the inverter and DC/DC converter for the fuel cell is then proposed. Simulation result is used to support the analysis.

  • PDF

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

Power Quality Improvement of an Electric Arc Furnace Using a New Universal Compensating System

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein;Ali Yazdian-Varjani
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.195-204
    • /
    • 2006
  • This paper presents a new compensating system, consisting of series and shunt active filters, for mitigating voltage and current disturbances. The shunt filter is used to compensate for unbalanced and distorted load currents. The series filter comprises two inverters, used to suppress voltage disturbances and handle source currents independently. This configuration is devised to reduce the overall cost of active compensators by using low-frequency high-current switches for the latter inverter. The filters are controlled separately using a novel control strategy. Since voltages at the point of common coupling contain interharmonics, conventional methods cannot be used for extracting voltage references. Therefore, voltage references are obtained from generated sinusoidal waveforms by a phase-locked loop. Current references are detected based on rotating frame vector mapping. Simulation results are presented to verify the system.

멀티레벨 전압형 인버터를 사용한 무효전력보상장치

  • Min, Wan-Gi;Kim, Byeong-Cheol;Jeon, Hyeong-Seok;Kim, Hyeong-Gon;Sin, Seok-Du;Jang, Seong-Nam;Lee, Gwang-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07h
    • /
    • pp.21-25
    • /
    • 1999
  • This paper proposes a novel control strategy of SVC(Static var compensator) using cascade multilevel inverter. To control the reactive power instantaneously, the dq-dynamic system model is described and analyzed. A single pulse pattern based on the SHE(Selective Harmonic Elimination) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is applied to adjust the DC capacitor voltage at the scheme level. From the simulation, it is verified that this proposed control scheme make the dynamic control response of SVC fast, the current harmonics low, and the DC capacitor voltage balanced.

  • PDF