• Title/Summary/Keyword: low dose gamma radiation

Search Result 232, Processing Time 0.03 seconds

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

Effects of Antioxidants on the Gamma-Radiation Damage of the Cultured Vascular Smooth Mucle Cells of Rat Aorta

  • Lee, Jong-Doo;Choi, Hyoung-Chul;Kang, Young-Jin;Kim, Myung-Se;Lee, Kwang-Youn
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.11 no.5
    • /
    • pp.189-195
    • /
    • 2007
  • To study the protective effects of antioxidants on the radiation damages of the cells, vascular smooth muscle cells(VSMC) from thoracic aorta of Sprague-Dawley rats were cultured and irradiated with gamma-ray. Cell viability was measured by direct cell counting and MTT assay, and flow cytometry was performed to measure fractional distributions of the cells. Gamma-ray irradiation inhibited cell proliferations accompanied with decreased G1 phase and increased S- and G2/M phases, and the maximum effects were observed at 1500 or 2000 cGy. Submaximal concentrations of antioxidants, such as allopurinol, vitamin C, N-acetylcycteine(NAC), lipoic acid, dihydrolipoic acid and rebamipide tended to increase the cell viability suppressed by low dose of radiation(500 cGy), and enalapril and vitamin E increased it significantly. Allopurinol, vitamin E, NAC, lipoic acid, captopril and enalapril significantly increased G1 phase. Allopurinol and vitamin E tended to increase c-Myc expression, detected by Western blot, that was reduced by the radiation, and enalapril increased it significantly. The cell viability and c-Myc expression were highly correlated(r=0.97) with each other. These results suggest that antioxidants, especially enalapril and vitamin E, recover the viability of VSMC from gamma-radiation injury, through a mechanism which includes increase of c-Myc protein expression.

Changes in the Seed Viability and DPPH-radical Scavenging of Helianthus annuus. Seeds According to Low Dose ${\gamma}$-ray irradiation (감마선 조사-해바라기 종자의 저장기간에 따른 종자활력과 추출물의 항산화활성)

  • Kim, Sun-Il;Lee, Hyun-Hwa;Kim, Chun-Sung;Seo, Myung-Deok;Lee, Sook-Young
    • Applied Biological Chemistry
    • /
    • v.51 no.2
    • /
    • pp.148-152
    • /
    • 2008
  • This study was to elucidate the effect of low dose gamma (${\gamma}$)-ray irradiation on the germination, seedling growth and antioxidant activity in sunflower seeds. The seed germination was stimulated in the range of 2.7${\sim}$8.0% by low dose ${\gamma}$-ray irradiation compared with that of the control; however, the germination of seeds stored for 4 months after irradiated was decreased at all low dose ${\gamma}$-ray irradiation groups. Especially, the germination rate of 32 Gy-irradiated seed group was much lower than that of the other groups and 8 Gy was the optimal radiation dose for germination at room temperature. Though there was variation with storage time and temperature, seedling growth stored at 10$^{\circ}C$ for 4 months after irradiated was promoted at the 1 Gy ${\gamma}$-ray irradiation group compared to seed stored at 25$^{\circ}C$. For the antioxidant activity of ${\gamma}$-ray irradiated seeds extract, 4 Gy and 32 Gy groups were significantly increased by 68.83% and 95.44%, respectively, compared to control at the concentration of 100 ${\mu}g$/ml.

${\gamma}-ray$ Effects on Steroid Hormone Concentration of Mouse Ovarian Follicles (생쥐의 난소내 스테로이드호르몬 농도에 미치는 ${\gamma}$-선의 영향)

  • Lee, Young-Keun;Kim, Jin-Kyu;Yoon, Yong-Dal
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.179-188
    • /
    • 1994
  • Mice were whole body irradiated with dose of 2.88Gy and 7.2Gy(Co-60) in order to observe the morphological and functional changes in radio sensitive mouse ovary. Microtechnical sectionates of $7{\mu}m$ thickness from ovary were made for light microscopy and concentrations of progesterone, testosterone and estradiol in ovarian homogenates were analyzed by radioimmunoassay. Gamma radiation resulted in the increase of atretic ratio of preantral and antral follicles, the increase of progesterone concentration in ovarian homogenates, and the low level of testosterone and estradiol. It is suggested that radiation protect the activity of $3{\beta}-HSD$(hydroxysteroid dehydrogenase) and isomerase in the follicular theca cell followed by low level of testosterone and estradiol and thereafter follicular atresia proceed.

  • PDF

Radioresistance of Acorus calamus to Gamma Ray Irradiation

  • Lee, Ja-Hyun;Kang, Si-Yong;Lee, Geung-Joo;Lee, Seong-Gene;Kim, Sun-Kook;Han, Tae-Ho
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.2
    • /
    • pp.119-125
    • /
    • 2011
  • Acorus calamus is an indigenous hydrophyte used as phytoremediation and water purification as well as medicinal herb. Irradiation of gamma ray was performed to investigate the effect on radioresistance of A. calamus on in vitro. Various doses (20-500 Gy) of gamma rays were irradiated to in vitro plantlets. The effect of irradiation was studied on survival rate, shoot formation and growth rate. The survival and multiplication rate was remarkably decreased with the increase of radiation dose. The growth of plantlets was significantly increased in comparison to the control at low doses. The hermetic effect of radiation was appeared in A. calamus. It was significantly decreased or interrupted above 250 Gy. The mean 50% lethal dose ($LD_{50}$) was extremely high as 240 Gy. We conclude that A. calamus had remarkably high radioresistance compared with other plant species.

High alloyed new stainless steel shielding material for gamma and fast neutron radiation

  • Aygun, Bunyamin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.647-653
    • /
    • 2020
  • Stainless steel is used commonly in nuclear applications for shielding radiation, so in this study, three different types of new stainless steel samples were designed and developed. New stainless steel compound ratios were determined by using Monte Carlo Simulation program Geant 4 code. In the sample production, iron (Fe), nickel (Ni), chromium (Cr), silicium (Si), sulphur (S), carbon (C), molybdenum (Mo), manganese (Mn), wolfram (W), rhenium (Re), titanium (Ti) and vanadium (V), powder materials were used with powder metallurgy method. Total macroscopic cross sections, mean free path and transmission number were calculated for the fast neutron radiation shielding by using (Geant 4) code. In addition to neutron shielding, the gamma absorption parameters such as mass attenuation coefficients (MACs) and half value layer (HVL) were calculated using Win-XCOM software. Sulfuric acid abrasion and compressive strength tests were carried out and all samples showed good resistance to acid wear and pressure force. The neutron equivalent dose was measured using an average 4.5 MeV energy fast neutron source. Results were compared to 316LN type stainless steel, which commonly used in shielding radiation. New stainless steel samples were found to absorb neutron better than 316LN stainless steel at both low and high temperatures.

Evaluation of the Utility of a Volumetric Modulated Arc Therapy Specific Patient Quality Assurance using Software-based Quality Assurance System (소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Kwon, Kyung-Tae
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.39-45
    • /
    • 2018
  • The purpose of this study is to evaluate the usefulness of a software-based quality assurance system based on Volumetric Modulated Arc Therapy treatment plan. Evaluate treatment plan through the D VH analysis, PTV mean dose ($D_{mean}$) and PTV 95% dose($D_{95}$) compare the MFX based on original treatment plan, Average error rate was $0.9{\pm}0.6%$, $1.0{\pm}0.8%$, respectively. Measuring point dose using phantom and ion chamber, the average error rate between the ionization chamber and MFX was $0.9{\pm}0.7%$, $1.1{\pm}0.7%$ (high dose region), $1.1{\pm}0.9%$, $1.2{\pm}0.7%$ (low dose region). The average gamma though of MFX and $Delta^{4PT}$ is $98.7{\pm}1.2%$, $98.4{\pm}.3%$, respectively. Through this study, A software based QA system that simplifies hardware based QA procedures that involve a lot of time and effort. It can be used as a simple and useful tool in clinical practice.