• Title/Summary/Keyword: low conductivity

Search Result 1,713, Processing Time 0.027 seconds

A Review on Thermal Conductivity of Polymer Composites Using Carbon-Based Fillers : Carbon Nanotubes and Carbon Fibers

  • Hong, Jin-Ho;Park, Dong-Wha;Shim, Sang-Eun
    • Carbon letters
    • /
    • v.11 no.4
    • /
    • pp.347-356
    • /
    • 2010
  • Recently, the use of thermal conductive polymeric composites is growing up, where the polymers filled with the thermally conductive fillers effectively dissipate heat generated from electronic components. Therefore, the management of heat is directly related to the lifetime of electronic devices. For the purpose of the improvement of thermal conductivity of composites, fillers with excellent thermally conductive behavior are commonly used. Thermally conductive particles filled polymer composites have advantages due to their easy processibility, low cost, and durability to the corrosion. Especially, carbon-based 1-dimensional nanomaterials such as carbon nanotube (CNT) and carbon nanofiber (CNF) have gained much attention for their excellent thermal conductivity, corrosion resistance and low thermal expansion coefficient than the metals. This paper aims to review the research trends in the improvement of thermal conductivity of the carbon-based materials filled polymer composites.

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

Thermo-electrical properties of randomly oriented carbon/carbon composite

  • Raunija, Thakur Sudesh Kumar;Supriya, N.
    • Carbon letters
    • /
    • v.22
    • /
    • pp.25-35
    • /
    • 2017
  • The aim of the work was to investigate the thermo-electrical properties of low cost and rapidly produced randomly oriented carbon/carbon (C/C) composite. The composite body was fabricated by combining the high-pressure hot-pressing (HP) method with the low-pressure impregnation thermosetting carbonization (ITC) method. After the ITC method step selected samples were graphitized at $3000^{\circ}C$. Detailed characterization of the samples' physical properties and thermal properties, including thermal diffusivity, thermal conductivity, specific heat and coefficient of thermal expansion, was carried out. Additionally, direct current (DC) electrical conductivity in both the in-plane and through-plane directions was evaluated. The results indicated that after graphitization the specimens had excellent carbon purity (99.9 %) as compared to that after carbonization (98.1). The results further showed an increasing trend in thermal conductivity with temperature for the carbonized samples and a decreasing trend in thermal conductivity with temperature for graphitized samples. The influence of the thickness of the test specimen on the thermal conductivity was found to be negligible. Further, all of the specimens after graphitization displayed an enormous increase in electrical conductivity (from 190 to 565 and 595 to 1180 S/cm in the through-plane and in-plane directions, respectively).

Alternating-Current Electrical Conduction Properties of DyCoO3 Ceramics (DyCoO3 세라믹스의 교류전도특성)

  • Jung, Woo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2010
  • The ac, dc conductivity and dielectric properties of $DyCoO_3$ were reported in the temperature range of 77 - 300K and in the frequency range of 20 Hz - 100 kHz. It was observed that at low temperature, ac conductivity is much higher than dc conductivity and the hopping carrier between localized states near the Fermi level was the dominant loss mechanism. A comparison of the measured ac conductivity $\sigma(\omega)$ was made with some of the models of hopping conductivity of the proposed earlier in the literature. It was observed that in $DyCoO_3$ the measured ac conductivity, over the entire frequency and temperature region, can be explained reasonably well by assuming two contributions $\sigma_1(\omega)$ and $\sigma_2(\omega)$ to the measured $\sigma(\omega)$. The first, $\sigma_1(\omega)$, which dominates at low temperature, may be due to impurity conduction in a small polaron; the second, $\sigma_2(\omega)$, which dominates at higher temperatures, depending on the frequency of measurements, may be due to the hopping of a small polaron and is reasonable for the dielectric relaxation peak.

Physical Properties of Lithium Co-polyelectrolyte Based on Imidazolium and Ammonium-type Ionic Liquids

  • Cha, E.H.;Lim, S.A.;Kim, D.W.;Lee, J.K.;Park, J.H.
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.3
    • /
    • pp.198-202
    • /
    • 2010
  • Lithium co-polyelectrolyte-ionic liquid systems, using poly (lithium 2-acrylamido-2-methyl propanesulfonate; PAMPSLi) and polyvinyl formamid (PVF) were prepared and their electrochemical and physical properties were measured. The conductivity of co-polymer systems, PAMPSLi/PVF/N, N-dimethyl-N-propyl-N-butylammonium tricyanomethanide (PAMPSLi/PVF/$N_{1134}$TCM) and PAMPSLi/PVF/N, N-dimethyl-N-propyl-N-butylammonium dicyanamide (PAMPSLi/PVF/$N_{1134}$DCA) exhibited low viscosity ($N_{1134}$TCM:$N_{1134}$DCA 28.6cP, 28.7cP) and higher conductivity ($2.48{\times}10^{-3}Scm^{-1}$, $2.2{\times}10^{-3}Scm^{-1}$) than homopolymer system. The ionic conductivity PAMPSLi/PVF/1-ethyl-3-methyl imidazolium dicyanamide (PAMPSLi/PVF/emImDCA) exhibited $1.54{\times}10^{-3}Scm^{-1}$ and low viscosity (emImDCA: 28.09cP). High flexibility of imidazolium cation and dissociation of lithium cation from the co-polymer chains were affected by high conductivity and low viscosity.

Swelling and hydraulic characteristics of two grade bentonites under varying conditions for low-level radioactive waste repository design

  • Chih-Chung Chung;Guo-Liang Ren;I-Ting Chen;Che-Ju, Cuo;Hao-Chun Chang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1385-1397
    • /
    • 2024
  • Bentonite is a recommended material for the multiple barriers in the final disposal of low-level radioactive waste (LLW) to prevent groundwater intrusion and nuclear species migration. However, after drying-wetting cycling during the repository construction stage and ion exchange with the concrete barrier in the long-term repository, the bentonite mechanical behaviors, including swelling capacity and hydraulic conductivity, would be further influenced by the groundwater intrusion, resulting in radioactive leakage. To comprehensively examine the factors on the mechanical characteristics of bentonite, this study presented scenarios involving MX-80 and KV-1 bentonites subjected to drying-wetting cycling and accelerated ion migration. The experiments subsequently measured free swelling, swelling pressure, and hydraulic conductivity of bentonites with intrusions of seawater, high pH, and low pH solutions. The results indicated that the solutions caused a reduction in swelling volume and pressure, and an increase in hydraulic conductivity. Specifically, the swelling capability of bentonite with drying-wetting cycling in the seawater decreased significantly by 60%, while hydraulic conductivity increased by more than three times. Therefore, the study suggested minimizing drying-wetting cycling and preventing seawater intrusion, ensuring a long service life of the multiple barriers in the LLW repository.

Studies on Polymer Coating in Soybean Seeds 1. Difference of Electrolyte Leaching of Polymeric Coating Soybean Seed (대두종자의 polymer coating 연구 1. polymer coating 종자의 conductivity 차이)

  • 이성춘
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.2
    • /
    • pp.158-164
    • /
    • 1994
  • These experiment were conducted to evaluate the environmentally acceptable polymers, and 10 polymers were used in these study, and to investigate conductivity, germination percentage, water uptake of polymeric coating soybean seed. The conductivity of polymeric coating seed is higher than that of none coating seed and the highest conductivity was obtained with waterlock coating seed among the 10 polymer coating seed. As the soaking time was long, the conductivity was increased. The conductivity of large seed was higher than that of small seed, and that of long period storage seed was higher than that of short period storage seed. The effects of seed coating polymers on uptake water were various, and daran 8600 inhibited uptake water of low quality seed. The waterlock, captan, klucel and sacrust was rised germination percentage, and daran 8600 was declined germination percentage, and the effect of coating polymers on germination percentage of low quality seed was higher than that of high quality seed.

  • PDF

Heat transfer enhancement of metal hydride $(Mm\;(La_{0.6-0.8})\;Ni_{4.0}Co_{0.6}Mn_{0.2}Al_{0.2})$ for hydrogen storage (수소저장용 금속수소화물$(Mm\;(La_{0.6-0.8})\;Ni_{4.0}Co_{0.6}Mn_{0.2}Al_{0.2})$의 전열촉진)

  • Bae, Sang-Chul;Yang, Yang;Masanori, Monde
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.33-36
    • /
    • 2006
  • The effective thermal conductivities of $Mm\;(La_{0.6-0.8})\;Ni_{4.0}Co_{0.6}Mn_{0.2}Al_{0.2}$ (TL-492) with hydrogen and helium have been examined. Experiment results show that pressure has great influence on effective thermal conductivity in Low pressure range (below 0.5 MPa). And that influence decreases rapidly with increase of gas pressure. The reason is at low pressure, the mean free path of gas becomes greater than effective thickness of gas film which is important to the heat transfer mechanism in this research. And, carbon fibers have been used to try to enhance the poor thermal conductivity of TL-492. Three types of carbon fibers and three mass fractions have been examined and compared. Naturally, the highest effective thermal conductivity has been reached with carbon fiber which has highest thermal conductivity, and highest mass fraction. This method has acquired 4.33 times higher thermal conductivity than pure metal hydrides with quite low quantity of additives, only 0.99wt% of carbon fiber. This is a good result comparing to other method which can reach higher effect ive thermal conductivity but needs much higher mass fraction of additives too.

  • PDF

Electrochemical Characterization of Lithium Polyelectrolyte Based on Ionic Liquid

  • Cha, E.-H.;Lim, S.-A.;Kim, D.-W.;Choi, N.-S.
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.3
    • /
    • pp.271-275
    • /
    • 2009
  • Five novel lithium polyelectrolyte-ionic liquid systems, using poly (lithium 2-acrylamido-2-methyl propanesulfonate; PAMPSLi) were prepared and their electrochemical properties were measured. The ionic conductivity of the PAMPSLi/1-ethyl-3-methylimidazolium tricyano methanide (emImTCM) system was exhibited high conductivity (1.28 $\times$ $10^{-3}$ $S/cm^{-1}$). The high conductivity and low viscosity of PAMPSLi/emImTCM system is due to the high flexibility of imidazolium cation and dissociation of lithium cation from the polymer chains. The PAMPSLi/N,N-dimethyl-N-propyl-Nbutylammonium tricyanomethanide ($N_{1134}TCM$) and PAMPSLi/N, N-dimethyl-N-propyl-N-butylammonium dicyanamide ($N_{1134}DCA$) systems showed fairly high conductivity (6.3 $\times$ $10^{-4}$ $S/cm^{-1}$, 6.0 $\times$ 10.4 S/cm.1). PAMPSLi/Trihexyl (tetradecyl) phosphonium bis (trifluoromethane sulfonyl) amide ($P_{66614}TFSA$) exhibited low conductivity (2.22 $\times$ $10^{-5}$ $Scm^{-1}$) and thermally stable over 400$^{\circ}C$.

Microstructure control and change in thermal conductivity of 8YSZ/SiO2 multi-compositional coating by suspension plasma spraying

  • Jeon, Hak-Beom;Lee, In-Hwan;An, Gye Seok;Oh, Yoon-Suk
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.6
    • /
    • pp.450-454
    • /
    • 2018
  • In recent years, thermal insulation coating technology for automotive engine parts has received significant attention as a means of improving the thermal efficiency of automotive engines. One of the characteristics of thermal insulation coatings is their low thermal conductivity, and, materials such as YSZ (Yttria-stabilized zirconia), which have low thermal conductivity, are used for this purpose. This research presents a study of the changes in the microstructure and thermal conductivity of $8YSZ/SiO_2$ multi compositional thermal insulation coating for different compositions, and particle size distributions of suspension, when it is subjected to suspension plasma spraying. To obtain a porous coating structure, the mixing ratio of 8YSZ and $SiO_2$ particles and the particle sizes of the $SiO_2$ were changed. The microstructure, phase formation behavior, porosity and thermal conductivity of the coatings were analyzed. The porosities were found to be 1.2-32.1%, and the thermal conductivities of the coatings were 0.797-0.369 W/mK. The results of the study showed that the microstructures of the coatings were strongly influenced by the particle size distributions, and that the thermal conductivities of the coatings were greatly impacted by the microstructures of the coatings.