• Title/Summary/Keyword: load test

Search Result 8,113, Processing Time 0.049 seconds

Noise Condition and Reduction Method for Diesel-locomotive Load Test Building (부하시험장 소음 실태 및 저감방안)

  • 조준호;이덕희;박준서;이규진
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.969-974
    • /
    • 2002
  • Recently, many studies are performed according to increased interests about factory or room acoustics. In this study, the inside and environmental noise conditions of Diesel-locomotive load test building were investigated by multi-channel noise measurement system. In addition to this, the mitigation effects of environmental noise from this test building were analyzed using commercial software.

  • PDF

Implementation of the Dynamic Simulator for Predicting Operating Characteristics of Three-Phase Induction Motors (유도전동기의 운전 특성 예측을 위한 동적 시뮬레이터 구성)

  • Pyon, H.S.;Hahn, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.906-908
    • /
    • 2000
  • This paper presents dynamic modeling and simulation of induction motors. Equivalent circuit parameters measured by do test, no-load test and locked-rotor test were used as the input data for computer simulation. Operating characteristics of an induction motor were predicted by Matlab/simulink when changing load torque, opening and reclosing of phase a of the stator and three-phase fault at machine terminals.

  • PDF

Preliminary Load Tests for the Design of Large Diameter Drilled Shaft by Bi-directional Loading Method at Toe (대구경 현장타설말뚝의 설계를 위한 선단재하방법에 의한 시험말뚝 재하시험)

  • Song, Myung-Jun;Park, Yung-Ho;Kim, Dong-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.89-98
    • /
    • 2005
  • Preliminary pile load tests for the design of large diameter drilled shaft were performed on two of reduced scale(D=1370mm) test piles. The maximum loads of 2350 tonf in each direction were applied using bi-directional hydraulic jacks(Osterberg Cell) at toe. Neither of the test piles yielded in terms of skin friction and end bearing. Comparisons of the test results with several methods that estimate pile capacity show that the method of Horvath and Kenney(1979) for skin friction and Zhang and Einstein(1998) for end bearing were most appropriate for the site. The test results were directly applied to pile design in case RQD of skin and toe was larger than that of the test pile. It is desirable, therefore, to consider not only unconfined compression strength but also rock mass properties(i.e. TCR, RQD) for skin friction and end bearing evaluation in the future.

  • PDF

Experimental Evaluation of the Performance of Large-Capacity Mounts for Naval Shipboard Equipments (함정탑재장비용 대용량 마운트의 성능시험평가)

  • Moon, Seok-Jun;Kim, Heung-Sub;Park, Jin-Woo;Park, Jin-Ho;Oh, Kwang-Suk;Jeong, Jong-Ahn
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.3
    • /
    • pp.275-281
    • /
    • 2015
  • Mounts for shipboard equipment in naval ships play an important role for vibration and shock suppression. New large-capacity resilient mounts, SDR-D30 and SDR-D45, have been developed. This paper involves performance tests for the mount which have maximum load of 30 kN and 45 kN, respectively. The performance tests have been carried out for several mounts based on military standards, such as MIL-M-19863D(SH), MIL-M-21693C(SH), MIL-M-17508F(SH), and MIL-S-901D(NAVY). The test items consist of deflection at upper rate load test, dynamic stiffness, uniformity, static load-deflection(axial, transverse and longitudinal), drift test, fatigue test, and shock test. From these performance tests, it is confirmed that the two mounts have good performances based on military standards.

A Scale-Effect of O-Cell Pile Load Test with Variable End Plate (가변선단재하판을 이용한 양방향말뚝재하시험의 치수 효과)

  • Joo, Yong-Sun;Kim, Nak-Kyung;Kim, Ung-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.884-890
    • /
    • 2009
  • The bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of the bi-direction can be known by using the loading of the end plate and two step procedures. The first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell, operated with end plate of 3 type on sand layer according to the relative density, loose, medium and dense conditions.

  • PDF

Mechanical Properties and Cross-sectional Surface Evaluation of Dental Ceramic Abutment (치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가)

  • Hwang, Jun Ho;Kwon, Sung-Min;Choi, Sung Gi;Sung, Mi Ae;Lee, Kyu-Bok
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.5
    • /
    • pp.309-315
    • /
    • 2018
  • The purpose of this study is to assess the mechanical properties of the ceramic abutment with washer. In this study, ceramic abutment were used, tested with $30^{\circ}$ compression load, shear fatigue, adaptation accuracy test(rotation angle, contact interval), removal torque force test, torsional breaking force test. The $30^{\circ}$ compression load was 729 N, the shear fatigue load was 275 N, adaptation accuracy test of rotation angle was within $3^{\circ}$, contact interval within $10{\mu}m$, and removal torque force test value is $18.88N{\cdot}cm$, torsional breaking force test value is $35.52N{\cdot}cm$. Ceramic abutment with a washer fitted have sufficient mechanical strength and may be substituted for titanium abutment.

Development of Short-span Precast Concrete Panels for Railway Bridge (철도교용 단지간 프리캐스트 콘크리트패널의 개발)

  • Seol, Dae-Ho;Lee, Kyoung-Chan;Kim, Ki-Hyun;Youn, Seok-Goo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.545-553
    • /
    • 2016
  • This paper presents experimental static test results of the precast concrete panels developed for short-span concrete bridge deck form. Different from LB-DECK, concrete rib attached to the bottom surface of concrete panel, and Top-bar is not used at the top surface of concrete panel. Number of concrete ribs and cross-section details of concrete rib are determined from the analytical results of parametric study considering the span length and the thickness of concrete bridge decks. Shear rebars are installed at the top surface of concrete panel for composite action between precast concrete panel and cast-in-place concrete. In order to evaluate the safety and the serviceability of the developed short-span concrete panel subjected to design load, static load test is conducted. Three test panels with span length of 1.6m are fabricated, and during the load test displacements, strains and cracks of test panels are measured and final failure modes are investigated. Serviceability of the test panels is evaluated based on the results of displacements, cracking load, and crack width at the design load level. Safety is also evaluated based on the comparison of the ultimate strength and the factored design load of test panels. Based on the test results, it is confirmed the short-span precast concrete panel satisfies the serviceability and safety regulated in design codes. In addition, the range of span length of concrete bridge decks for the short-span concrete panel is discussed.

Study(I) on Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - An Analysis of Sharing Ratio of Skin Friction to Total Bearing Capacity (SRF) by Analyzing Pile Load Test Data - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(I) - 재하시험 자료 분석을 통한 전체지지력에 대한 주면마찰력의 분담율(SRF) 분석 -)

  • Choi, Yongkyu;Lee, Wonje;Lee, Chang Uk;Kwon, Oh-Kyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.8
    • /
    • pp.17-30
    • /
    • 2019
  • Based on pile load test results for various pile types that were constructed in-situ and pile design data of prebored PHC piles, the ratio of skin friction to total capacity (SRF) was analyzed. A SRF distribution range from the pile load test results for pilot test prebored PHC piles was 42~99% regardless of relative penetration lengths, soil types, and pile load test types. However, a SRF distribution range from the pile design data for prebored PHC piles was 20~53% regardless of relative penetration lengths and pile diameters. Also, a SRF distribution range from the restrike dynamic pile load test results for pretest working prebored PHC piles was a scattered range of 4~83% regardless of pile diameters, relative penetration lengths and soil types. The scattered SRF of pretest working piles was caused to the quality control issue on the filling of cement milk around piles and this quality control issue should be improved. The average SRF calculated by the current design method was estimated to be 2.2 times lower than the average SRF of the pilot test piles. It is because skin friction resistance is calculated at a very low level. Therefore, a new design method for skin friction will be proposed based on this study.

Experimental Studies on PSC Airpit-Slab with Fire Resistance Panel under Static and Dynamic Loads (내화패널이 부착된 프리캐스트 PSC 풍도슬래브의 정적/동적하중에 관한 실험연구)

  • Kim, Tae Kyun;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.245-253
    • /
    • 2012
  • In the longway tunnel and underground traffic road, the structure of transverse ventilation system is constructed by the airpit slab. In this study, the full scale specimens of the PSC airpit slab that attached fire resistance panel are performed the static and dynamic loading tests for evaluation of bending capacity. The first of all, it confirmed the evaluations about the fundamental efficiency of the fire resistance panel and PSC slab by the 3-point bending test and pull-off test. The tests are performed for evaluation of the bending resistance under ultimate static load and the bonded capacity under dynamic fatigue load. A fatigue test is performed for an investigation of the effect on wind pressure that is developed by transit of traffic. The damage or debonding on surface between fire resistance panel and PSC slab was not developed in dynamic fatigue load test, also the behavior of the specimens is very stable and the debonding of the fire resistance panel attached at the bottom surface of PSC slab was not developed in static load test, too. Therefore, the crack or debonding of the fire resistance panel will be not developed by external loads during the construction or completion of the precast fire resistance system.

Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell (동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석)

  • Kang, Eun-Chul;Park, Yong-Dai;Lee, Euy-Joon;Yun, Tae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF