• Title/Summary/Keyword: liquid column

Search Result 1,375, Processing Time 0.033 seconds

High-Performance Liquid Chromatographic Analysis of Chrysin Derivatives on A $Nova-Pak^{\circledR}C_{18}$ Column

  • Kim, Kyoung-Soon;Shin, Joon-Su;Park, You-Mie;Lee, Sanghyun;Kim, Yang-Bae;Kim, Bak-Kwang
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.613-616
    • /
    • 2002
  • A high-performance liquid chromatographic method has been developed for the separation and quantification of chrysin and synthetic chrysin derivatives (12 chrysin alkyl and 7 chrysin acyl derivatives). The chromatography was performed using a $Nova-Pak^{\circledR}C_{18}$ column. A RP-HPLC was performed by using a binary mixture (MeOH-10 mM H$_3$PO$_4$) as a mobile phase, and the column temperature was maintained at room temperature. A flow rate was 1.0 ml/min, and the effluent was monitored at a wavelenth of 280 nm. The retention times for chrysin acyl and alkyl derivatives were within 10 minutes and 20 minutes, respectively. The absolute recovery of samples were all over 96%. The detection limits were 0.1~18 ng at S/N = 3 ratio.

Determination of Nebramycin Factor 2,4,5,5',6 and Kanamycin A in Fermentation Broth of Streptoalloteichus hindustanus ATCC 31218 Mutant Using 2,4-Dinitrofluorobenzene(DNFB) as a Derivatizing Agent by High Performance Liquid Chromatography (HPLC법에 의한 2,4-디니트로플루오로벤젠을 유도체화제로 한 Streptoalloteichus hindustanus ATCC 31218 변이균의 배양액 중 네브라마이신 펙터 2,4,5,5',6, 가나마이신 A 분석)

  • 박영근;박명용;김승철;양호길
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • A procedure for the high-performance liquid chromatographic determination of Nebramycin factors in fermentation broth of Streptoalloteichus hindustanus ATCC 31218 mutant was investigated using pre-column derivatization and LTV detection. The method is based on pre-column derivatization of Nebramycin factors with 2,4-dinitrofluorobenzene(DNFB) in the presence of Tris (hydroxymethyl)aminoethane. The chromatographic separation of derivatives of Nebramycin factors and unknown impurities is achieved using reversed-phase column (NOVA-PAK $C_{18}$, Waters Co.) and AcCN : H$_{2}$O : AcOH (53.0:46.5:0.5) as a mobile phase. The mixture of these derivatives were separated within 35 minutes and the optimum wavelength($\lambda_{max}$ ) of the UV detector was 353 nm. The linearity of response for derivatives of Nebramycin factors is demonstrated for concentrations up to 500 $\mu\textrm{g}$/ml and the relative standard deviation is less than 0.79%. Detection limit was 1.67 ng for the 10 $\mu\textrm{l}$ sample volume employed.

  • PDF

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Chung, Lan;Lee, Joung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure (실물크기 구조물에 설치된 동조액체질량감쇠기의 성능실험)

  • Heo, Jae-Sung;Park, Eun-Churn;Lee, Sung-Kyung;Lee, Sang-Hyun;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Joo, Seok-Jun;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.2
    • /
    • pp.161-168
    • /
    • 2008
  • In this paper, a tuned liquid mass damper(TLMD) was proposed and experimentally investigated on its control performance, which can control bi-axial responses of building structures by using only one device. The proposed TLMD controls the structural response in a specific one direction by using a liquid sloshing of TLCD. Also, the TLMD reduces the response of structures in the other orthogonal direction by behaving as a TMD that uses mass of the container itself and liquid within container of TLCD installed on linear motion guides. Force-vibration tests on a real-sized structure installed with the TLMD were performed to verify its independent behavior in two orthogonal directions. Test results showed that the responses of a structure were considerably reduced by using the proposed TLMD and its usefulness for structural control in two orthogonal directions.

Residence Time Distribution in the Chromatographic Column: Applications in the Separation Engineering of DNA

  • Park, Young G.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.117-125
    • /
    • 2003
  • Experimental and theoretical works were performed for the separation of large polyelectrolyte, such as DNA, in a column packed with gel particles under the influence of an electric field. Since DNA quickly orient in the field direction through the pores, this paper presents how intraparticle convection affects the residence time distribution of DNAs in the column. The concept is further illustrated with examples from solid -liquid systems, for example, from chromatography Showing how the column efficiency is improved by the use of a n electric field. Dimensionless transient mass balance equations were derived, taking into consideration both diffusion and electrophoretic convection. The separation criteria are theoretically studied using two different Peclet numbers in the fluid and solid phases. These criteria were experimentally verified using two different DNAs via electrophoretic mobility measurements. which showed how the separation position of the DNAs varies in the column in relation to the Peg/Pef values of an individual DNA. The residence time distribution was solved by an operator theory and the characteristic method to yield the column response.

Comparison of methods for Determination of Aflatoxins in food Products (식품중 Aflatoxin 측정방법의 비교)

  • 김면희
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 1996
  • A procedure for the determination of Aflatoxins in food and grains which utilizes reversed phased liquid chromatographic (LC) analysis with postcolumn derivatization by an electrochemical cell and determination with a fluorescence detector has been evaluated. The LC mobile phase was water-acetonitrile-methanol (6+2+2) with 1mM KBr and 1 mM HNO3 which gave baseline separation for the four Aflatoxins (AfB1, AfB2, AfG1, AfG2). The electrochemical cell set at 7V, generated bromine and derivatized aflatoxins B1 and G1, The derivatives were detected by the fluorescence detector. The aflatoxins in naturally contaminated corn samples were isolated by three different cleanup procedures: the AOAC method I column(CB method), a rapid filtrate column (Romer's column), and an immunoaffinity column. The final extract were quantitated with fluordensitometric TLC and the LC postcolumn derivatization techniques. The results were quite similar, however the LC technique showed less interferences and could be automated. Samples of corn, raw peanuts, peanut butter and dried dates were also analyzed successfully with this procedure.

  • PDF

Axial and Radial Distributions of Bubble Holdup in a Slurry Bubble Column with Pilot Plant Scale (파일럿규모 슬러리 기포탑에서 기포체류량의 축방향, 반경방향 분포)

  • Lim, Dae-Ho;Jang, Ji-Hwa;Kang, Yong;Jun, Ki-Won
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.200-205
    • /
    • 2011
  • Axial and radial distributions of bubble holdup were investigated in a slurry bubble column with pilot plant scale(D=1.0 m). Effects of gas velocity, surface tension of continuous liquid medium and solid fraction in the slurry phase on the axial and radial distributions of bubble holdup were examined. The bubble holdup decreased with increasing radial dimensionless distance from the center of the column, while it increased with increasing dimensionless distance in the axial direction from the distributor, in all the cases studied. The radial non-uniformity of bubble holdup increased with increasing gas velocity but decreasing surface tension of liquid medium, while it was not dependent upon the solid fraction in the slurry phase. The axial non-uniformity of bubble holdup increased with increasing gas velocity, but it does not change considerably with variations of liquid surface tension or solid fraction in the slurry phase . The axial and radial distributions of bubble holdup were well correlated in terms of operating variables within this experimental conditions.

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속액체크로마토그라피를 이용한 홍삼 사포닌의 정량)

  • Kim, Cheon-Suk;Kim, Se-Bong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • Major saponins in ginseng were analysed using reverse phase high performance liquid chromatography with binary mobile phase gradient control system instead of normal phase column. The optimum condition were as following : reverse phase column; ${\mu}{\beta}ondapak\;C_{18}$ column (Waters, $3.9mm{\times}300\;mm,\;5{\mu}m$), methyl cyanaide/water binary mobile phase gradient control system, solvent flow rate; 1.5 ml/min, and UV($203{\mu}m$ ) detector. The complete separation of ginsenoside $Rb_1,\;Rb_2,\;Rc,\;Rd,\;Re,\;Rf\;and\;Rg_1$ was achieved within 55 min. The Regression coefficients of the calibration curves for seven ginsenosides were 0.99.

  • PDF

High-Performance Liquid Chromatographic Determination of Tricyclazole Residues in Rice Grain, Rice Straw, and Soil

  • Lee, Young-Deuk;Lee, Jung-Hun
    • Applied Biological Chemistry
    • /
    • v.41 no.8
    • /
    • pp.595-599
    • /
    • 1998
  • An analytical method was developed to determine tricyclazole residues in rice grain, straw, and soil using high-performance liquid chromatography (HPLC) with ultraviolet absorption detection. Tricyclazole was extracted with methanol from moist rice grain, straw, and soil samples. n-Hexane washing was employed to remove nonpolar co-extractives during liquid-liquid partition. Tricyclazole was then extracted with dichloromethane from alkaline aqueous phase, while acidic interferences remained in the phase. Dichloromethane extract was further purified by silica gel column chromatography prior to HPLC determination. Reverse-phase HPLC using an octadecylsilyl column was successfully applied to separate and quantitate the tricyclazole residue in sample extracts monitored at ${\lambda}_{max}$ 225nm. Recoveries from fortified samples averaged $95.5{\pm}3.0%\;(n=6),\;87.5{\pm}20.%\;(n=6),\;and\;84.3{\pm}2.8%$ (n=12) for rice grain, straw, and soil, respectively. Detection limit of the method was 0.02 mg/kg for rice grain and soil samples while 0.05 mg/kg for rice straw samples. The proposed method was reproducible and sensitive enough to evaluate the safety of tricyclazole residues in rice grain, straw, and soil.

  • PDF

Optimal Shape of LCVA considering Constraints on Liquid Level (수위의 구속조건을 고려한 LCVA의 최적형상)

  • Park, Ji-Hun;Kim, Gi-Myun;Lee, Sung-Kyung;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.429-437
    • /
    • 2009
  • This study addresses the optimal shape of a LCVA maximizing its vibration control effect through numerical parametric study. Various LCVAs having the same total mass and tuning frequency are designed with constraints on the dimensions and water level, and one obtaining the highest equivalent damping ratio of the controlled system is chosen as an optimal solution. As a result, it was found that the limit on the variation of the water level in the vertical liquid column plays an important role constraining the shape of the LCVA. As the LCVA width perpendicular to the plane of liquid motion increases, the equivalent damping ratio rises with slowdown so that determination of the proper width is important in design of the LCVA shape.