Browse > Article

Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure  

Heo, Jae-Sung (단국대학교 건축공학과)
Park, Eun-Churn (단국대학교 건축공학과)
Lee, Sung-Kyung (단국대학교 건축공학과)
Lee, Sang-Hyun (단국대학교 건축공학과)
Kim, Hong-Jin (경북대학교 건축공학과)
Jo, Ji-Seong (포스코건설 기술연구소)
Cho, Bong-Ho (포항산업과학연구원)
Joo, Seok-Jun (㈜티이솔루션)
Min, Kyung-Won (단국대학교 건축공학과)
Publication Information
Journal of the Computational Structural Engineering Institute of Korea / v.21, no.2, 2008 , pp. 161-168 More about this Journal
Abstract
In this paper, a tuned liquid mass damper(TLMD) was proposed and experimentally investigated on its control performance, which can control bi-axial responses of building structures by using only one device. The proposed TLMD controls the structural response in a specific one direction by using a liquid sloshing of TLCD. Also, the TLMD reduces the response of structures in the other orthogonal direction by behaving as a TMD that uses mass of the container itself and liquid within container of TLCD installed on linear motion guides. Force-vibration tests on a real-sized structure installed with the TLMD were performed to verify its independent behavior in two orthogonal directions. Test results showed that the responses of a structure were considerably reduced by using the proposed TLMD and its usefulness for structural control in two orthogonal directions.
Keywords
tuned liquid mass damper(TLCD); tuned liquid column damper(TLCD); tuned mass damper(TMD); bi-axial response; force-vibration test;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lu, L.Y. (2004) Semi-active modal control for seismic structures with variable friction dampers, Engineering structures, 26(4), pp.437-454   DOI   ScienceOn
2 Sakai, F., Takaeda S., Tamaki T. (1989) Tuned Liquid Column Damper-New Type Device for Suppression of Building Vibrations, Proc. Int Conf. on Hight Rise Building, Nanjing, China, pp.25-27
3 Ghosh, A., Basu, B. (2006) A closed-form optimal tuning criterion for TMD in damped structures, Structural control and health monitoring, 14, pp.681-692
4 Mohammad, R.O., Mohammad, R., Amir, K.T. (2006) Tuned Mass Dmaper For Seismic Response Reduction of Tehran Tower, 4th International Conference on Earthquake Engineering, Taipei, Taiwan, Paper No.132
5 Wright, G. (2002) Steadying Influence-Damper systems save millions in cost, while reducing lateral movement in tall buildings, Building Design & Constuction
6 Banerji, P., Murudi, M. Shah, A.H. Popplewell, N. (2000) Tuned liquid dampers for controlling earthquake response of structures, Earthquake engineering & structural dynamics, 29(5), pp.587-602   DOI   ScienceOn
7 Desu, N.B., Deb, S.K., Dutta, A. (2006) Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings, Structural control and health monitoring, 13(5), pp.897-916   DOI   ScienceOn
8 Li, C., Liu, Y. (2002) Active multiple tuned mass dampers for structures under the ground acceleration, Earthquake engineering & structural dynamics, 31(5), pp.1041-1052   DOI   ScienceOn
9 김홍진, 김현배, 조지성, 이상현, 우성식, 최기영 (2006) LCVA를 이용한 초고층건물의 풍진동 제어성능 실험 평가, 대한건축학회 학술발표대회 논문집, 26(1), pp.13-16
10 Kareem, A., Kijewski, T., Tamura, Y. Mitigation of Motions of Tall Buildings with Specific Examples of Recent Applications, Wind and Structures, 2(3), pp.201-251
11 Haskett, T., Breukelman, B., Robinson, J., Kottelenberg J. Tuned Mass Dampers Under Excessive Structural Excitation, Response of structures to extreme loading (Conference), pp.37-43
12 Gao, H., Kwok, K.S.C., Samali, B. (1999) Characteristics of multiple tuned liquid column dampers in suppressing structural vibration, Engineering structures, 21(4), pp.316-331   DOI   ScienceOn
13 김홍진, 김형섭, 민경원, 오정근 (2003) TMD와 TLCD의 지진응답에 대한 제어성능 평가 연구, 한국지진공학회논문집, 7(5), pp.85-91
14 Chang, K. C., Lai, M. L., Soong, T.T., Hao, D. S. (1993) Seismic Behavior and Design Guidelines for Steel Frame Structures with Added Viscoelastic Dampers, Technical Report NCEER-93-0009, National Center for Earthquake Engineering Research, Buffalo, NY
15 이상현, 박은천, 윤경조, 이성경, 유은종, 민경원, 정란, 민정기, 김영찬 (2006) 실물 크기 구조물의 강제진동실험 및 지진응답 모사를 위한 HMD제어기 설계, 한국지진공학회논문집, 10(6), pp.103-114   과학기술학회마을   DOI
16 Reiterer, M., Ziegler, F. (2005) Bi-axial Seismic Activation of Civil Engineering Structures Equipped with Tuned Liquid Column Dampers, JSEE, 7(1), pp.45-60
17 손동인 (2001) 건축구조물에서 지진하중에 대한 점탄성 감쇠기의 최적 설계, 석사학위논문, 서울 대학교
18 Soong, T.T., Dargush, G.F. (1997) Passive Energy Dissipation Systems in Structural Engineering, New York, John Wiley & Sons
19 Den Hartog, J.P. (1956) Mechanical Vibrations, 4th edn, McCraw-Hill, New York