• Title/Summary/Keyword: line resistance

Search Result 1,381, Processing Time 0.027 seconds

Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection (X-선 투과검사를 이용한 저항 점용접부 품질평가기법)

  • Lee, Jong-Dae;Lee, So-Jeong;Bang, Jung-Hwan;Yoon, Gil-Sang;Kim, Mok-Soon;Kim, Jun-Ki
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

Evaluation and Model Development of Transfer Resistance Factors for Bulk Freight Transportation (벌크화물운송의 환적저항요인 평가 및 모형 개발)

  • Choi, Chang-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.3
    • /
    • pp.1-11
    • /
    • 2016
  • The present study aims to evaluate transfer resistance factors in railway stations and draw new implications. The data used for the model estimation are RP (revealed preference) data and SP (stated preference) data. Two types of models were used for the analysis: integration model which combined line-haul stage, transfer stage and shuttle stage and separation model which assessed the three stages separately. The results revealed that while bulk freight shippers mainly focused on line-haul stage, they put emphasis on transfer stage as well. It's especially notable that transfer stage was considered more important than shuttle stage. Therefore, in future transportation policies concerning rail freight, it would be crucial not only to enhance the competitiveness of line-haul stage but also make improvements in transfer stage regarding railway stations.

Eveluation of line probe assay in detecting rifampicin resistance of mycobacterium tuberculosis

  • Park, Young-Kil;Cho, Snag-Hyun;Kuk, Na-Byoung;Song, Chul-Yong;Bai, Gill-Han;Kim, Sang-Jae
    • Journal of Microbiology
    • /
    • v.35 no.3
    • /
    • pp.177-180
    • /
    • 1997
  • The purpose of this study was to evaluate the efficiency of Line Probe Assay (LiPA) in detecting the rpoB gene mutation of clinically isolated Mycobacterium tuberculosis (MTB) and to compare the level of resistance to the various rifamycins with their mutation sites. The mutation in the rpoB gene was found in 84 (97.6%) out of 86 rifampicin (RMP) resistant strains as determined by LiPA. No mutation was observed in 2 RMP resistant strains and in any of 38 RMP susceptible strains tested. Only one of 3 strains with .DELTA.5/R5, one of 2 strains with .DELTA.3, and one of 3 strains with .DELTA.2/R2 LiPA profile showed a slightly lower level of resistance to the rifapentine than the other strains. Although we could not find correlations between mutation sites in the rpoB gene and the level of susceptibility to the various rifamycins, the LiPA is recommended as a fast screening tool for detection of RMP resistant MTB.

  • PDF

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

Design of a Microwave Active Resonator Using Defected Ground Structure with Islands (DGSI) (격리패턴을 지닌 결함접지구조를 이용한 초고주파용 능동공진기)

  • Hwang, Mun-Su;Oh, Seong-Min;Ahn, Dal;Lim, Jong-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1814-1819
    • /
    • 2007
  • A new active resonator using defected ground structure with islands (DGSI) is proposed. The proposed resonator is composed of the conventional microstrip line with DGSI and negative resistance of active devices. The negative resistance part is realized by field effect transistor (FET) series feedback circuits. The characteristic of the proposed resonator with DGSI is improved by combining the negative resistance part with the parallel microstrip line structure with islands, where the electric field is formed the most strongly. The measured improvement of the proposed active resonator with DGSI are 4.55dB and 0.32dB in S21 and S22, respectively, at the resonant frequency whorl it is compared to the existing passive resonator having DGSI only.

Characteristics of Seasonal Variations of Ground Electrodes by Field Test (현장시험에 의한 접지전극의 년간 변화 특성)

  • Shim, K.B.;Kim, K.C.;Lee, H.S.;Park, J.D.;Park, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.500-501
    • /
    • 2006
  • Ground resistance is very important element in distribution line of multi-grounded system. Therefore, use several kind of ground electrode materials to get ground resistance. In this study, examine about characteristics of seasonal variations of ground resistance by several kind of ground electrode material that is used to ground electrode of distribution line, and compares and evaluated characteristics of each ground electrode material.

  • PDF

Screening of RAPD Markers for Fluoride Resistance in Bombyx mori L.

  • Chen, Keping;Yao, Qin;Li, Muwang;Wang, ong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.7 no.1
    • /
    • pp.11-14
    • /
    • 2003
  • NF733xin, the near allele line was obtained by means of crossing and backcrossing the silkworm race T6, which contained fluoride resistance major gene, to race 733xin, which was highly susceptible to fluoride toxicity. Two hundred RAPD random primers were used in the RAPD analysis of these 3 strains. Two molecular markers, OPB-08850 and OPB-10917, were obtained. OPB-10917 was used to detect the backcross generations. It was found that all the fluoride resistant individuals in each backcross generation had the same special band. These results proved that this marker was reliable.

A Fault Location Algorithm for Transmission Lines in the High-Resistance Fault (송전선로에서의 고저항 지락고장시 고장거리 추정에 관한 알고리즘)

  • Park, Hong-Kyu;Lee, Myoung-Soo;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1363-1365
    • /
    • 1999
  • This paper Presents an algorithm for the computation of fault location for a transmission line by means of the voltage and current signals. It is impossible to calculate the accurate fault distance, because of the fault resistance and fault current which are unknown. All Currents in the lines are divided by the current distribution factor, so the fault current through the fault resistance can be represented by using data from one terminal of transmission line. This algorithm proposed can calculate the fault distance with only the faulty phase information.

  • PDF

Characteristics of AlNd thin film for TFT-LCD bus line

  • Kim, Dong-Sik;Kwak, Sung-Kwan;Chung, Kwan-Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.59-59
    • /
    • 2000
  • Recently low resistance of bus line is required for large screen size TFT-LCD panels. As a result, lower resistance Al-alloy is currently reviewed extensively. The resistivity is required smaller than 10 $\mu$$\Omega$cm. In this paper, Al-Nd thin film were deposited on glass substrates by D.C. magnetron sputtering system under various condition. Its properties were characterized by SEM, AFM, XRD, 4-ping-probe. The optimal condition of Al-Nd was 12$0^{\circ}C$, 125W, 0.4Pa, 30sccm(Ar) and 35$0^{\circ}C$, 20min. annealing. At that condition the resistivity of Al-Nd(2wt.%) was about 4 $\mu$$\Omega$cm. The minimum contact resistance of ITO/Nd was about 110$\mu$$\Omega$cm in the condition of 30$0^{\circ}C$, Ar 30 sccm. O2.

  • PDF

A Study on the Characteristics of wave Resistance and Hull Form obtained at Finte Water Depth (유한수심(有限水深)에서의 선형계획(線型計劃))

  • Hyo-Chul,Kim;J.C.,Seo
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 1980
  • From the singularity distribution which obtained by minimum wave resistance condition, optimum hull form is obtained by stream line trancing method as Inui and Pien did. Thus obtained hull form has a extruded bottom along a keel line. Therefore the hull form must be modified to have flat bottom. This modification process is conducted by putting a fictitious bottom. It is found out that the wave resistance does not significantly alter at design speed even though the hull form has remarkably changed at the bottom. Therefore flattening the bottom by the effect of depth may be more rational for practical hull form design than ordinary manual hull-form modification.

  • PDF