• Title/Summary/Keyword: limiting process

Search Result 477, Processing Time 0.03 seconds

Simultaneous Quench Characteristic of Resistive Superconducting Fault Current Limiting Modules by using BSCCO Tape

  • Yang Seong-Eun;Ahn Min-Cheol;Park Dong-Keun;Youn Il-Goo;Jang Dae-Hee;Ko Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.43-45
    • /
    • 2006
  • Recently, the resistive Fault Current Limiter (SFCL) made with Coated Conductor (CC) has been researched with an advanced capability in CC. Current limiting elements must be connected in series in order to fabricate the resistive SFCL having large capacity. By the way, unless the applied voltage in the SFCL is distributed to the elements when the fault occurred, those elements will be critically damaged. Thus simultaneous quench of the elements is an important factor to design the resistive SFCL. In this paper, simultaneous quench characteristics of current limiting module by using BSCCO 2223 were researched before manufacturing the resistive SFCL by using CC. At the first fault stage, the elements generated the resistance at the same time. However, the unequal voltage is applied to the each element in process of time. The method is suggested to solve the problem of the unequal distribution. These experimental results will play an important part in developing for the resistive SFCL by using CC.

CHANGE-POINT ESTIMATION WITH SAMPLE FOURIER COEFFICIENTS

  • Kim, Jae-Hee
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.11a
    • /
    • pp.109-114
    • /
    • 2002
  • In this paper we propose a change-point estimator with left and right regressions using the sample Fourier coefficients on the orthonormal bases. The asymptotic properties of the proposed change-point estimator are established. The limiting distribution and the consistency of the estimator are derived.

  • PDF

An Invariance Principle of Uniform CLT for the Baker's Transformation

  • Jongsig Bae
    • Communications for Statistical Applications and Methods
    • /
    • v.2 no.1
    • /
    • pp.194-200
    • /
    • 1995
  • The baker's transformation is an ergodic transformation defined on the half open unit square. This paper considers the limiting begavior of the partial sum process of a martingale sequence constructed from the baker's transformation in the context of an invariance principle of a uniform central limit theorm.

  • PDF

Statistical Tests for Process Capability Index Cp Based on Mixture Normal Process (혼합 정규공정 하에서의 공정능력지수 Cp에 대한 가설검정)

  • Cho, Joong Jae;Heo, Tae-Young;Jeong, Jun Chel
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.2
    • /
    • pp.209-219
    • /
    • 2014
  • Purpose: The purpose of this study is to develop the statistical test for process capability index $C_p$ based on mixture normal process. Methods: This study uses Bootstrap method to calculate the approximate P-value for various simulation conditions under mixture normal process. Results: This study indicates that our proposed method is effective way to test for process capability index $C_p$ based on mixture normal process. Conclusion: This study finds out that statistical test for process capability index $C_p$ based on mixture normal process is useful for real application.

Experimental Studies on Limiting Concentration of High Saline Feed Solution in Electrodialysis (전기투석 시스템에서 고농도 수용액의 한계 농축에 대한 연구)

  • Junsu, Jang;Bumjoo, Kim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.64-68
    • /
    • 2023
  • The salt concentration process in electrodialysis, which uses electrical energy to enhance ion concentrations in an aqueous electrolyte solution, has been studied on the transfer phenomenon of ions and water molecules over the ion exchange membrane. In this paper, we investigated various parameters for limiting concentration of electrolyte solution and the electroosmosis phenomenon in an electrodialysis system by varying salt concentration of electrolyte solution. The electroosmotic water transport was analyzed by measuring the ions and water fluxes in electrolyte solutions having two different NaCl concentrations (NaCl 2M/4M), and concentration change was observed for various volume ratios of the diluted reservoir to the concentration one As a result, it was found that the higher concentration of the aqueous electrolyte solution, the lower electroosmosis, and the higher volume ratio led to a higher concentration in the dilute reservoir, so the limiting concentration was enhanced and the specific energy consumption decreased.

A Unit Root Test Based on Bootstrapping

  • Shin, Key-Il;Kang, Hee-Jeong
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.1
    • /
    • pp.257-265
    • /
    • 1996
  • We consider nonstationary autoregressive autoregressive process with infinite variance of error. In the case of infinite cariance, the limiting distribution of the estimated coefficient is different from that under the finite cariance assumption. In this paper we show that the bootstrap method can be used to approximate the distribution of ordinary least squares estimator of the coefficient in the first order random walk process with infinite variance through some empirical studies and we suggest a test procedure based on bootstrap method for the unit root test.

  • PDF

A study on $YBa_2Cu_3O_x$ thick films by diffusion process for a superconducting fault current limiter (확산법을 이용한 사고전류제한기용 $YBa_2Cu_3O_x$ 후막연구)

  • Cho, Dong-Eon;Yim, Seong-Woo;Choi, Myung-Ho;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1516-1518
    • /
    • 1998
  • $YBa_2Cu_3O_x$(Yl23) Superconducting thick films on $Y_2BaCuO_5$(Y211) substrate were Prepared by surface diffusion process between $BaCuO_2$+CuO composite coating powder and a Y2ll substrate. X-ray diffraction shows that the Yl23 layer onto Y2ll substrate is the orthorhombic crystal structure. The specimen heated at $940^{\circ}C$ for 2h showed the maximum $J_c$ fo 500A/$cm^2$. Based on optimal condition, the superconducting fault current limiter(FCL) having a current limiting area 1mm wide and 66mm long was fabricated on Y211 substrate. A typical current limiting waveform was measured. When a voltage of 3V was applied, the fault current with a peak of 15A was limited to about 0.11A.

  • PDF

Transcriptome Analysis of Phosphate Starvation Response in Escherichia coli

  • Baek, Jong-Hwan;Lee, Sang-Yup
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.244-252
    • /
    • 2007
  • Escherichia coli has a PhoR-PhoB two-component regulatory system to detect and respond to the changes of environmental phosphate concentration. For the E. coli W3110 strain growing under phosphate-limiting condition, the changes of global gene expression levels were investigated by using DNA microarray analysis. The expression levels of some genes that are involved in phosphate metabolism were increased as phosphate became limited, whereas those of the genes involved in ribosomal protein or amino acid metabolism were decreased, owing to the stationary phase response. The upregulated genes could be divided into temporarily and permanently inducible genes by phosphate starvation. At the peak point showing the highest expression levels of the phoB and phoR genes under phosphate-limiting condition, the phoB- and/or phoR-dependent regulatory mechanisms were investigated in detail by comparing the gene expression levels among the wild-type and phoB and/or phoR mutant strains. Overall, the phoB mutation was epistatic over the phoR mutation. It was found that PhoBR and PhoB were responsible for the upregulation of the phosphonate or glycerol phosphate metabolism and high-affinity phosphate transport system, respectively. These results show the complex regulation by the PhoR-PhoB two-component regulatory system in E. coli.

Appling Multi-dimensional Limiting Process (MLP) to shallow water flow simulation (MLP 기법을 이용한 천수흐름 수치모의)

  • An, Hyun-Uk;Yu, Soon-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.537-537
    • /
    • 2012
  • 천수방정식의 수치모형은 하천의 유량예측, 홍수범람해석, 해일 모의 등에 널리 사용되고 있고, 그 결과는 수자원 관리, 재난 대책 등 정책적인 의사결정에 있어 유용한 자료로 활용되고 있다. 이처럼 천수방정식의 수치모형은 연구목적뿐만 아니라 실생활에 있어서도 큰 영향을 미치고 있으며, 이에 보다 정확하고 효율적인 수치모형의 구축이 수리/수자원/방재분야에서 중요한 영역이 되고 있다. 본 연구는 정확하고 안정적인 수치모의를 위해 천수방정식의 수치모형에 MLP(Multi dimensional Limiting Process)기법을 적용한 후 다차원 모의 시 MLP의 수치 진동 제어 성능을 검증하고자 하였다. MLP기법은 다차원에서 수치진동을 억제할 수 있도록 개발된 기법으로, 기존 TVD 제어자(limiter)과 MLP의 차이점은 기존 제어자들이 흐름이 발생하는 셀 경계면에서 재구성된 값이 Maximum Principle을 만족시키도록 제어자를 유도하는데 반해, MLP는 셀 절점에서 Maximum Principle을 만족시키도록 제어자를 유도한다는데 있다. MLP기법은 압축성 유체를 표현하는 2, 3차원 오일러 방정식에 적용되어 기존의 제어자들에 비해 안정적이며 정확한 수치모의를 가능하게 하는 것이 검증되었다. 하지만 천수방정식에 적용된 예는 없으며, 이에 본 연구는 천수방정식에 MLP를 적용하고 천수방정식 수치모형 검증에 주로 사용되는 수치모의를 통해 MLP의 수치 진동 제어 성능을 검증하였다. 모의 결과, MLP는 2차원 천수방정식에 있어서도 기존의 제어자들과 비교하여 수치진동을 보다 잘 제어하는 것으로 판단된다. MLP의 사용으로 인해 불연속면 근처에서 정확도가 향상되었고 수치진동이 발생하지 않아 보다 안정적인 모의가 가능하였다.

  • PDF

Flame Retardancy of Cellulose Fabrics Treated with 3-(Hydroxyphenyl Phosphinyl) Propanoic Acid

  • Zhang, Lianping;Kim, Sam-Soo;Lee, Jae-Woong
    • Textile Coloration and Finishing
    • /
    • v.20 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • 3-(Hydroxyphenyl phosphinyl) propanoic acid (HPPA) has been one of the most commonly used durable flame retardant agents for polyethylene terephthalate (PET) for many years. We intended to explore the application of HPPA to cellulose fabrics as formaldehyde-free phosphorus based flame retardants (FRs) through green chemistry process. The flame retardancy of the flame-retardant treated cellulose fabrics were characterized by using inductively coupled plasma spectroscopy (ICP) and limiting oxygen index (LOI). Structural changes of the treated cellulose fabrics were carried out by thermogravimetric analysis (TGA) and Fourier transform infrared (FT-IR) spectroscopy. To enhance the flame retardancy of HPPA treated cellulose fibers, glycerol polyglycidyl ether (GPE), a crosslinking agent was employed. Both HPPA and GPE treated cotton fabric imparted an LOI value over 26.