• Title/Summary/Keyword: limiting distribution

Search Result 399, Processing Time 0.022 seconds

EXTENSION OF MULTI-DIMENSIONAL LIMITING PROCESS ONTO THREE-DIMENSIONAL UNSTRUCTURED GRIDS (다차원 공간 제한 기법의 3차원 비정렬 격자계로 확장)

  • Park, J.S.;Kim, C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.404-411
    • /
    • 2010
  • The present paper deals with the continuous work of extending multi-dimensional limiting process (MLP), which has been quite successfully proposed on two- and three-dimensional structured grids, onto the unstructured grids. The basic idea of the present limiting strategy is to control the distribution of both cell-centered and cell-vertex physical properties to mimic a multi-dimensional nature of flow physics, which can be formulated as so called the MLP condition. The MLP condition can guarantee a high-order spatial accuracy without yielding spurious oscillations. Recently, MLP slope limiter was proposed based on the MUSCL-type reconstruction in two-dimensional case and it can be readily extended to three-dimensional case. Through various numerical analyses and extensive computations, it is observed that the proposed limiters are quite effective in controlling numerical oscillations and very accurate in capturing both discontinuous and continuous multi-dimensional flow features on 3-D tetrahedral grids.

  • PDF

Effect of inserting resistance's magnitude on OCR trip time in a short-circuit of distribution system (배전계통 사고시 투입저항 크기가 OCR트립 시간에 미치는 영향)

  • Ahn, Jae-Min;Kim, Jae-Chul;Lim, Sung-Hun;Kim, Jin-Seok;Moon, Jong-Fil
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.154-155
    • /
    • 2007
  • Increase of fault current due to larger power demand has increased the possibility of the breakdown of the power system. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. In this paper, the fault current limiter, which consists of a ideal switch as a trigger part and the limiter as the limiting part, has been applied into the distribution system. From the analysis for the fault current limiting operation of SFCL, the inserting resistance's magnitude has been confirmed to affect OCR trip time in a short-circuit of distribution system.

  • PDF

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (반주기 이후 동작 하이브리드 초전도 전류제한기와 보호기기 협조 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1832-1837
    • /
    • 2011
  • The fault current has increased due to the large power demand in power distribution system and network distribution system. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) has been notified. However, the conventional SFCL has some problems such as cost, operation, recovery, loss. To solve some problems, the hybrid superconducting fault current limiter using the fast switch was proposed. However, hybrid SFCL also has a problem that is protection coordination in power distribution system with hybrid SFCL. In this paper, the fault current limiting characteristics of hybrid SFCL with first half cycle non-limiting operation according to the fault angle, the resistance of superconducting element, and the magnitude of Current Limit Resistor (CLR) which are the components of hybrid SFCL were analyzed through the experiments.

Simulation for current limiting characteristics of a resistive SFCL in the 22.9 kV distribution system (배전급 저항형 초전도 한류기의 전류제한특성에 대한 EMTDC 시뮬레이션)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Hwang, Si-Dole;Kim, Sang-Joon
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.268-271
    • /
    • 2000
  • We simulated the current limiting characteristics of a resistive SFCL with 16 ${\Omega}$ of resistance for a single line-to-ground fault in the 22.9 kV system. The transient current during the fault increased up to 6.33 kA, 5.80 kA and 3.71 kA without SFCL at the fault angles of 0${\circ}$,45${\circ}$ and 90${\circ}$, respectively. An resistive SFCL limited the fault current to 2.27 kA in a half cycle. The quench resistance of 16 ${\Omega}$ was suggested to be appropriate to limit the fault current in the 22.9 kV distribution system.

  • PDF

The Cluster Damage in a $extsc{k}th-Order$ Stationary Markov Chain

  • Yun, Seokhoon
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.2
    • /
    • pp.235-251
    • /
    • 1999
  • In this paper we examine extremal behavior of a $textsc{k}$th-order stationary Markov chain {X\ulcorner} by considering excesses over a high level which typically appear in clusters. Excesses over a high level within a cluster define a cluster damage, i.e., a normalized sum of all excesses within a cluster, and all excesses define a damage point process. Under some distributional assumptions for {X\ulcorner}, we prove convergence in distribution of the cluster damage and obtain a representation for the limiting cluster damage distribution which is well suited for simulation. We also derive formulas for the mean and the variance of the limiting cluster damage distribution. These results guarantee a compound Poisson limit for the damage point process, provided that it is strongly mixing.

  • PDF

Local Sensitivity Analysis using Divergence Measures under Weighted Distribution

  • Chung, Younshik;Dey, Dipak K.
    • Journal of the Korean Statistical Society
    • /
    • v.30 no.3
    • /
    • pp.467-480
    • /
    • 2001
  • This paper considers the use of local $\phi$-divergence measures between posterior distributions under classes of perturbations in order to investigate the inherent robustness of certain classes. The smaller value of the limiting local $\phi$-divergence implies more robustness for the prior or the likelihood. We consider the cases when the likelihood comes form the class of weighted distribution. Two kinds of perturbations are considered for the local sensitivity analysis. In addition, some numerical examples are considered which provide measures of robustness.

  • PDF

On Weak Convergence of Some Rescaled Transition Probabilities of a Higher Order Stationary Markov Chain

  • Yun, Seok-Hoon
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.3
    • /
    • pp.313-336
    • /
    • 1996
  • In this paper we consider weak convergence of some rescaled transi-tion probabilities of a real-valued, k-th order (k $\geq$ 1) stationary Markov chain. Under the assumption that the joint distribution of K + 1 consecutive variables belongs to the domain of attraction of a multivariate extreme value distribution, the paper gives a sufficient condition for the weak convergence and characterizes the limiting distribution via the multivariate extreme value distribution.

  • PDF

A Study on the Breakdown Characteristics of High Voltage Device using Field Limiting Ring and Side Glass Insulator Wall (전계제한테와 측면 유리 절연층을 사용한 고내압 소자의 항복 특성 연구)

  • Huh, Chang-Su;Chu, Eun-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1072-1074
    • /
    • 1995
  • Zinc-Borosilicate is used as a side insulastor wall to make high breakdown voltage with one Field Limiting Ring in a p-n junction. It is known that surface charge can be yield at the interface of Zinc-Borosilicate Glass/Silicon system. When the glass is used as a side insulator wall, surface charge varied potential distribution and breakdown voltage improved more than 660V without using more FLR.

  • PDF

Some nonparametric test procedure for the multi-sample case

  • Park, Hyo-Il;Kim, Ju-Sung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.1
    • /
    • pp.237-250
    • /
    • 2009
  • We consider a nonparametric test procedure for the multi-sample problem with grouped data. We construct the test statistics based on the scores obtained from the likelihood ratio principle and derive the limiting distribution under the null hypothesis. Also we illustrate our procedure with an example and obtain the asymptotic properties under the Pitman translation alternatives. Also we discuss some concluding remarks. Finally we derive the covariance between components in the Appendix.

  • PDF

Limiting Distributions of Trimmed Least Squares Estimators in Unstable AR(1) Models

  • Lee, Sangyeol
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.2
    • /
    • pp.151-165
    • /
    • 1999
  • This paper considers the trimmed least squares estimator of the autoregression parameter in the unstable AR(1) model: X\ulcorner=ØX\ulcorner+$\varepsilon$\ulcorner, where $\varepsilon$\ulcorner are iid random variables with mean 0 and variance $\sigma$$^2$> 0, and Ø is the real number with │Ø│=1. The trimmed least squares estimator for Ø is defined in analogy of that of Welsh(1987). The limiting distribution of the trimmed least squares estimator is derived under certain regularity conditions.

  • PDF