• 제목/요약/키워드: limiting distribution

검색결과 400건 처리시간 0.033초

Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.659-663
    • /
    • 2012
  • The application of large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer's impedance caused the short-circuit current of the power distribution system to be increase thus, the higher short-circuit current exceeded the cut-off ratings of the protective devices such as circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. In spite of excellent current limiting performances of the SFCL, on the other hand, the efforts to apply the SFCL into power system has been delayed due to both the limited spaces for the SFCL's installation and its long recovery time after the fault removal. In order to solve these problems, a hybrid SFCL, which can perform either first half cycle limiting of first half cycle non-limiting operation, has been developed by corporation of LSIS (LS Industrial System) and KEPCO (Korea Electric Power Corporation). In this paper, we tried to requirements hybrid SFCL by PSCAD/EMTDC. Simulation results of our analysis of the hybrid SFCL is that its accompanied the characteristics both the limit the fault current and quick recovery caused by the less impact from superconductor.

190 kVA급 초전도한류소자의 특성 (Characteristics of a 190 kVA Superconducting Fault current Limiting Element)

  • 마용호;이주영;박권배;오일성;류경우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

Test for the Presence of Seasonality in Time Series Models

  • 이성덕
    • Journal of the Korean Data and Information Science Society
    • /
    • 제12권1호
    • /
    • pp.71-78
    • /
    • 2001
  • Three test statistics are proposed for the presence of seasonality in multiplicative seasonal time series models. Further their common limiting distribution is derived under some assumptions.

  • PDF

Test of Homogeneity for a Panel of Seasonal Autoregressive Processes

  • Lee, Sung-Duck
    • Journal of the Korean Statistical Society
    • /
    • 제22권1호
    • /
    • pp.125-132
    • /
    • 1993
  • Large sample test of homogeneity for a panel of more than two seasonal autoregressive processes is derived and its limiting distribution is found. Detailed results are shown for the important special case that the seasonal and nonseasonal autoregressive components are both of order one.

  • PDF

Change-Point Estimation and Bootstrap Confidence Regions in Weibull Distribution

  • Jeong, Kwang-Mo
    • Journal of the Korean Statistical Society
    • /
    • 제28권3호
    • /
    • pp.359-370
    • /
    • 1999
  • We considered a change-point hazard rate model generalizing constant hazard rate model. This type of model is very popular in the sense that the Weibull and exponential distributions formulating survival time data are the special cases of it. Maximum likelihood estimation and the asymptotic properties such as the consistency and its limiting distribution of the change-point estimator were discussed. A parametric bootstrap method for finding confidence intervals of the unknown change-point was also suggested and the proposed method is explained through a practical example.

  • PDF

Ljung-Box Test in Unit Root AR-ARCH Model

  • Kim, Eunhee;Ha, Jeongcheol;Jeon, Youngsook;Lee, Sangyeol
    • Communications for Statistical Applications and Methods
    • /
    • 제11권2호
    • /
    • pp.323-327
    • /
    • 2004
  • In this paper, we investigate the limiting distribution of the Ljung-Box test statistic in the unit root AR models with ARCH errors. We show that the limiting distribution is approximately chi-square distribution with the degrees of freedom only depending on the number of autocorrelation lags appearing in the test. Some simulation results are provided for illustration.

A Test of Multivariate Normality Oriented for Testing Elliptical Symmetry

  • Park, Cheol-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권1호
    • /
    • pp.221-231
    • /
    • 2006
  • A chi-squared test of multivariate normality is suggested which is oriented for detecting deviations from elliptical symmetry. We derive the limiting distribution of the test statistic via a central limit theorem on empirical processes. A simulation study is conducted to study the accuracy of the limiting distribution in finite samples. Finally, we compare the power of our method with those of other popular tests of multivariate normality under a non-normal distribution.

  • PDF

A Rao-Robson Chi-Square Test for Multivariate Normality Based on the Mahalanobis Distances

  • Park, Cheolyong
    • Communications for Statistical Applications and Methods
    • /
    • 제7권2호
    • /
    • pp.385-392
    • /
    • 2000
  • Many tests for multivariate normality are based on the spherical coordinates of the scaled residuals of multivariate observations. Moore and Stubblebine's (1981) Pearson chi-square test is based on the radii of the scaled residuals, or equivalently the sample Mahalanobis distances of the observations from the sample mean vector. The chi-square statistic does not have a limiting chi-square distribution since the unknown parameters are estimated from ungrouped data. We will derive a simple closed form of the Rao-Robson chi-square test statistic and provide a self-contained proof that it has a limiting chi-square distribution. We then provide an illustrative example of application to a real data with a simulation study to show the accuracy in finite sample of the limiting distribution.

  • PDF

배전계통에 초전도 한류기 적용시 전류제한특성 (Limiting Current Characteristics using Superconducting Fault Current Limiter in Power System)

  • 김진석;임성훈;안재민;문종필;김재철;김철환;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.21-22
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) have proposed one of several countermeasures. Therefore, to introduce SFCL into power distribution system, the position of SFCL in power distribution system is selected among some cases. Each position changes fault current limiting characteristics and SFCL's requirement. In this paper, the characteristics of limiting fault current according to installed SFCL's location in power distribution system.

  • PDF

배전계통 초전도 한류기 동작특성에 따른 계통 영향 분석 (System Effects by Operation Characteristics of Superconducting Fault Current Limiters in Distribution Systems)

  • 이상봉;김철환;김규호;김재철;현옥배
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1135-1140
    • /
    • 2008
  • Superconducting fault current limiters (SFCL) have been progressing due to the development of superconducting technology. The resistor type SFCL is one of the promising current limiting devices in power system for its effective operation. For proper application and operation of a SFCL, the prior investigation of fundamental characteristics and its effects to the distribution systems are needed. The most important current limiting behavior of a SFCL is dominated by quenching and recovery characteristics. In this paper, the resistive type SFCL was developed by using EMTP/ATPDraw and MODELS language. The operating characteristics and current limiting behaviors of the SFCL in distribution systems have been simulated and investigated.