• 제목/요약/키워드: light curing

검색결과 464건 처리시간 0.023초

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

Self-compacting light-weight concrete; mix design and proportions

  • Vakhshouri, Behnam;Nejadi, Shami
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.143-161
    • /
    • 2016
  • Utilization of mineral and chemical admixtures in concrete technology has led to changes in the formulation and mix design in recent decades, which has, in turn, made the concrete stronger and more durable. Lightweight concrete is an excellent solution in terms of decreasing the dead load of the structure, while self-compacting concrete eases the pouring and removes the construction problems. Combining the advantages of lightweight concrete and self-compacting concrete is a new and interesting research topic. Considering its light weight of structure and ease of placement, self-compacting lightweight concrete may be the answer to the increasing construction requirements of slender and more heavily reinforced structural elements. Twenty one laboratory experimental investigations published on the mix proportion, density and mechanical properties of lightweight self-compacting concrete from the last 12 years are analyzed in this study. The collected information is used to investigate the mix proportions including the chemical and mineral admixtures, light weight and normal weight aggregates, fillers, cement and water. Analyzed results are presented in terms of statistical expressions. It is very helpful for future research to choose the proper components with different ratios and curing conditions to attain the desired concrete grade according to the planned application.

가시광선과 아르곤 레이저로 복합레진 중합시 미세누출에 관한 비교 연구 (MICROLEAKAGE OF COMPOSITE RESINS POLYMERIZED WITH ARGON LASER AND VISIBLE LIGHT)

  • 장기택;정태련;김종철
    • 대한소아치과학회지
    • /
    • 제23권4호
    • /
    • pp.899-905
    • /
    • 1996
  • For the purpose of evaluation of microleakage of class V resin restoration, 64 extracted bovine teeth were filled with two kinds of light curing composite resins(Z-100, Clearfil) and polymerized with 40 seconds of visible light and with 10 seconds of argon laser. After 1000 thermocycling($5^{\circ}C/55^{\circ}C$), specimens were placed in 1 % methylen blue dye solution for 72 hours in $37^{\circ}C$ water bath. The specimens were sectioned at center of filling body and the degree of dye penetration was observed with a stereomicroscope. The following results were obtained, 1. Differences of the microleakage of resin restorations polymerized with 10 seconds of argon laser and 40 seconds of visible light were statistically insignificant. 2. There was more microleakage in Z-100 than clearfil and there was a statistical significancy (p<0.05).

  • PDF

광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향 (Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength)

  • 유지아;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.324-335
    • /
    • 2011
  • 연구목적: 복합레진의 색조를 색 성분요소인 CIE $Lab^*$ 각 성분요소로 측정하고, 동일 시편에 대해서 중합률과 2축 굴곡강도(biaxial flexural strength)를 측정하여 이들의 상관관계를 비교함으로써 복합레진의 중합전, 후의 색 성분요소가 중합률과 물성에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: 두 종류의 복합레진 Premisa (Kerr Co.)와 Denfil (Vericom Co)의 법랑질 색조(A1, A2, A3, A4)와 상아질 색조(A2O, A3O)에 대해 원판형의 시편을 제작하여 색성분, 중합률 및 2축 굴곡강도를 측정하였다. 분광광도계를 이용하여 중합 전, 후 및 7일에 CIE $L^*,\;a^*,\;b^*$ 값을 측정하고, 같은 시편에 대해 근적외선분광기를 이용하여 중합 후 2시간과 7일에 중합률을 측정하였다. 중합 7일 후에 색 성분과 중합률을 측정한 후 만능시험기에서 2축 굴곡강도를 측정하였다. 색요소인 CIE $L^*,\;a^*,\;b^*$ 각각의 값과 중합률, 및 2축 굴곡강도의 상관관계를 분석하였다. 결과: 두 종의 광중합형 복합레진은 중합 전과 후에 색 성분요소, 즉 색조의 변화가 있었고, 광중합 후에도 시간이 경과하면서 중합률이 증가되었다. 중합률은 제품, 기간, 및 색조의 영향을 받고(3-way ANOVA, p < 0.05), 굴곡강도는 제품 및 색조의 영향을 받았다(2-way ANOVA, p < 0.05). 중합률은 Premisa 한 제품에서만 중합 전, 후의 CIE $a^*$ component와 유의한 상관관계를 보였고, 굴곡강도도 Premisa에서 CIE $a^*$ 및 CIE $b^*$ component와 음의 상관관계를 보였다(Pearson product moment correlation, p < 0.05). 결론: 광중합 복합레진의 중합률과 굴곡강도는 제품의 중합 전,후의 색 성분에 의해 영향을 받았다.

키랄네마틱액정-고분자 복합막의 경화거동과 내부구조에 관한 연구 (A Study on Curing Behaviors and Structures of Chiral Liquid Crystal-Polymer composite films)

  • 남수용;김종원;김용욱
    • 한국인쇄학회지
    • /
    • 제16권3호
    • /
    • pp.15-27
    • /
    • 1998
  • Several aspects of polymer dispersed liquid crystal(PDLC) film properties make them interesting for display application. Most versions of PDLC materials are able to modulate light without the use of polarizers, which offers advantages in optical throughput(brightness) and viewing angle compared to polarizer-based display. In this papers, we attemped to doe minimum of remaining liquid crystals at polymer network for the liquid crystal-polymer composite (LCPC) films. In results, best phase separation behaviors turned out liquid crystal/monomer/oligomer mixture system.

  • PDF

Comparison of polymerization shrinkage between halogen light curing unit and PAC

  • Lee, Jae-Ik;Park, Sung-Ho
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.583.2-583
    • /
    • 2001
  • In these days, as the patients requirements on ethetics are getting greater, so the restorative materials which match well with natural teeth colors are being developed. One of those materials is the composite resin. When we fill the composite resin into the prepared cavity, it makes some clinical problems because it shrinks during the polymerization. To resolve these problems, first we must have sufficient understandings on the polymerization of composite resin.(omitted)

  • PDF

UV경화성 수지를 이용한 미세패턴 형성에 관한 연구 (A Study on Micro-patterning used the UV-Curable Resin)

  • 남수용
    • 한국인쇄학회지
    • /
    • 제19권2호
    • /
    • pp.68-78
    • /
    • 2001
  • UV-curable resin has the properties of quick-drying, thigh productivity at low temperature, energy savint, space saving, solventless, non-polluting and low-stinking, and thus, UV-curing system has been widely used in the fields of printing inks, adhesives, paints and coating agents. This study has been executed to micro-patterning used UV-curable resin, The micro-patterning properties of this photoresist were investigated under irradiation of UV light low pressure mercury lamp. When the exposed photoresist film was developed by pure water developer, the resolution of this photoresist was about 50$\mu\textrm{m}$.

  • PDF

The Effect of Erythrosine-mediated Photodynamic Therapy on Intraorally Formed Biofilm on Titanium Surface

  • Park, Se-Hwan;Lee, Si-Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • International Journal of Oral Biology
    • /
    • 제37권3호
    • /
    • pp.103-108
    • /
    • 2012
  • The purpose of this study was to assess the efficacy of photodynamic therapy (PDT) using erythrosine and a halogen light source to treat a biofilm formed on a machined surface titanium disk in vivo. Ten volunteers carried an acrylic appliance containing six machined surface titanium disks on the upper jaw over a period of five days. After the five days of biofilm formation period, the disks were removed. PDT using 20 ${\mu}M$ erythrosine and halogen light was then applied to the biofilms formed on the disks. Experimental samples were divided into a negative control group (no erythrosine and no irradiation), E0 group (erythrosine 60s + no irradiation), E30 group (erythrosine 60s + halogen light 30s), and E60 group (erythrosine 60s + halogen light 60s). Following PDT, the bacteria in the biofilm were found to be detached from each disk. Each suspension with detached bacteria were diluted and cultivated on a blood-agar plate for five days under anaerobic conditions. The cultivated bacterial counts in the E60 group were significantly lower than the control group (86.4%) or E0 group (76.7%). In the experimental groups also, the light exposure time and bacterial counts showed a negative correlation. In conclusion, PDT using erythrosine and halogen light has bactericidal effects on biofilms formed on a titanium disk in vivo. Notably, applying 20 ${\mu}M$ erythrosine and 60 seconds of halogen light irradiation had a significantly potent effect.

Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement

  • Jafari, Zahra;Alaghehmand, Homayoon;Samani, Yasaman;Mahdian, Mina;Khafri, Soraya
    • Restorative Dentistry and Endodontics
    • /
    • 제43권3호
    • /
    • pp.27.1-27.9
    • /
    • 2018
  • Objectives: The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods: A total of 120 specimens of 2 shades (A1 and A3) and 2 thicknesses (1 and 2 mm) were fabricated using VITA Mark II (VM; VITA Zahnfabrik), IPS e.max CAD (IE; IvoclarVivadent), and VITA Suprinity (VS; VITA Zahnfabrik) (n = 10 per subgroup). The amount of light transmission through the ceramic specimens was measured by a radiometer (Optilux, Kerr). Light-cured resin cement samples (Choice 2, Bisco) were fabricated in a Teflon mold and activated through the various ceramics with different shades and thicknesses using an LED unit (Bluephase, IvoclarVivadent). In the control group, the resin cement sample was directly light-cured without any ceramic. Vickers microhardness indentations were made on the resin surfaces (KoopaPazhoohesh) after 24 hours of dark storage in a $37^{\circ}C$ incubator. Data were analyzed using analysis of variance followed by the Tukey post hoc test (${\alpha}=0.05$). Results: Ceramic thickness and shade had significant effects on light transmission and the microhardness of all specimens (p < 0.05). The mean values of light transmittance and microhardness of the resin cement in the VM group were significantly higher than those observed in the IE and VS groups. The lowest microhardness was observed in the VS group, due to the lowest level of light transmission (p < 0.05). Conclusion: Greater thickness and darker shades of the 3 types of CAD/CAM ceramics significantly decreased the microhardness of the underlying resin cement.