• Title/Summary/Keyword: level of detector

Search Result 506, Processing Time 0.024 seconds

Design of a Symbol Timing Recovery of QAM Using the Interpolation in AWGN channel (AWGN 채널에서 보간기를 이용한 QAM 방식에 대한 심볼동기회로 설계)

  • 박범대;오동진;김철성
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.77-80
    • /
    • 1999
  • This paper deals with a design of a symbol timing recovery circuit of QAM using the interpolation in AWGN channel. To reduce timing jitter and the amount of processing data, we employ MGA (Modified Gardner Algorithm) as a symbol timing error detector which is called NDA(Nondecision Directed Algorithm). We show the characteristics (S-curve and the variance) of timing error detector with the roll-off factor of a shaping filter, which are compared with GA. Also, we compare the BER curve of interpolation method with that of ideal case. The performance of the STR is shown to be close to that of ideal case. This result shows that this method can be useful to implement symbol timing recovery circuit for multi-level modulation.

  • PDF

FPGA Implementation for Real Time Sobel Edge Detector Block Using 3-Line Buffers (3-Line 버퍼를 사용한 실시간 Sobel 윤곽선 추출 블록 FPGA 구현)

  • Park, Chan-Su;Kim, Hi-Seok
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.10-17
    • /
    • 2015
  • In this Paper, an efficient method of FPGA based design and implementation of Sobel Edge detector block using 3-Line buffers is presented. The FPGA provides the proper and sufficient hardware for image processing algorithms with flexibility to support Sobel edge detection algorithm. A pipe-lined method is used to implement the edge detector. The proposed Sobel edge detection operator is an model using of Finite State Machine(FSM) which executes a matrix mask operation to determine the level of edge intensity through different of pixels on an image. This approach is useful to improve the system performance by taking advantage of efficient look up tables, flip-flop resources on target device. The proposed Sobel detector using 3-line buffers is synthesized with Xilinx ISE 14.2 and implemented on Virtex II xc2vp-30-7-FF896 FPGA device. Using matlab, we show better PSNR performance of proposed design in terms of 3-Line buffers utilization.

Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes (배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발)

  • Kim, Gye-Hong;Park, Chan-Hee;Jung, Chong-Hun;Lee, Kune-Woo;Seo, Bum-Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.123-128
    • /
    • 2006
  • A small radiation detection system is necessary for the direct characterization of alpha/beta-ray contamination inside pipes generated during the decommission of a nuclear facility. In this work, the new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for ${\alpha}/{\beta}$ simultaneous counting was designed as part of a development of a equipment capable of monitoring radiological contamination inside pipes. The optimum counting conditions in dimensions of scintillator and a detection system were experimentally confirmed and a performance of alpha/beta-ray discrimination was evaluated. As a result, optimum conditions of a detector suitable for monitoring radiological contamination inside pipes and a feasibility of application to pipe-inside were confirmed.

Design of the Detection Circuitry for the Characteristics of Micromachined Vibrating Gyroscope (미세가공 진동형 자이로스코프의 특성 감지 회로의 설계에 관한 연구)

  • U, Yeong-Sin;Byeon, Gwang-Gyun;Seo, Il-Won;Seong, Man-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.687-692
    • /
    • 1999
  • A new technique to measure low level capacitance variations of the gyroscope is proposed and verified by computer simulation. It is based on the new CV(capacitance-voltage) converter circuit biased by dc current source and the peak detector without low pass filter. The CV converter biased by dc current source provides good signal-to-noise ratio and this setup of the detection circuitry without low pass filter makes it possible to provide short settling time, that is, higher speed of measurement and wide operation range if only a few parameters are adjusted. The key parameters that affect the performance of the detection circuitry are illustrated and computer simulation results are presented. The demonstrated detection circuitry shows linear response from 10 fF to 130 fF at 10 kHz and shows good linearity.

  • PDF

A Compact and Fast Measurement System for the Detection of Small Capacitance

  • Youngshin Woo;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.1
    • /
    • pp.16-21
    • /
    • 2001
  • A new technique to measure low level capacitance variations of a gyroscope is proposed. It is based on the improved CVC(capacitance to voltage converter) biased by a d.c. current source and the peak detector without any low pass filter. This setup of the measurement system makes it possible to provide higher speed of measurement and wide operation range. The d,c, drift of the conventional CVC and stray capacitances are automatically compensated. Key parameters that affect the performance of the measurement system are illustrated and computer simulation results are presented. The demonstrated measurement system for micromachined gyroscope applications shows a linearity of 0.99972 and a resolution of 0.67fF from 10 fF to 120 fF at 10 kHz.

  • PDF

In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector

  • Ji, Young-Yong;Lim, Taehyung;Lee, Wanno
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.85-96
    • /
    • 2018
  • Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, $LaBr_3(Ce)$ scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an $LaBr_3(Ce)$ detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an $LaBr_3(Ce)$ detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.

Design of a 6-bit 500MS/s CMOS A/D Converter with Comparator-Based Input Voltage Range Detection Circuit (비교기 기반 입력 전압범위 감지 회로를 이용한 6비트 500MS/s CMOS A/D 변환기 설계)

  • Dai, Shi;Lee, Sang Min;Yoon, Kwang Sub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.4
    • /
    • pp.303-309
    • /
    • 2013
  • A low power 6-bit flash ADC that uses an input voltage range detection algorithm is described. An input voltage level detector circuit has been designed to overcome the disadvantages of the flash ADC which consume most of the dynamic power dissipation due to comparators array. In this work, four digital input voltage range detectors are employed and each input voltage range detector generates the specific clock signal only if the input voltage falls between two adjacent reference voltages applied to the detector. The specific clock signal generated by the detector is applied to turn the corresponding latched comparators on and the rest of the comparators off. This ADC consumes 68.82mW with a single power supply of 1.2V and achieves 4.9 effective number of bits for input frequency up to 1MHz at 500 MS/s. Therefore it results in 4.75pJ/step of Figure of Merit (FoM). The chip is fabricated in 0.13-um CMOS process.

Determination of Catecholamines and Their Metabolites in Rat Brain by High Performance Liquid Chromatography with Electrochemical Detector (HPLC-ECD에 의한 흰쥐 뇌 부위별 Catecholamine 및 대사산물의 신속정량법)

  • Ro, Ihl-Hyeob
    • YAKHAK HOEJI
    • /
    • v.32 no.1
    • /
    • pp.50-54
    • /
    • 1988
  • A simple and sensitive method was studied for the simultaneous determination of catecholamine, indoleamine and their related metabolites by high performance liquid chromatography with electrochemical detector. Norepinephrine, dopamine, serotonin and their metabolites of 3,4-dihydroxyphenylacetic acid, homovanillic acid, 5-indoleacetic acid were resolved from rat brain tissue homogenates by separation on reversed phase $C_{18}$ column with mobile phase consisting of monochloroacetate buffer (pH2.47), 1.42mM sodium octyl sulfonate and 7% acetonitrile. Both catechols and indoles can be eluted in 15min. The sensitivities of this method are sufficient for determination of at least 100 pg of neurochemical amines in brain samples, for example, frontal cortex, olfactory bulb, striatum, septum, hippocampus, thalamus, hypothalamus, medulla & pons and cerebellum. The highest level of dopamine was observed in striatum whereas norepinephrine and serotonin were in hypothalamus.

  • PDF

An analytical model considering temperature effects in self-signal processing infrared detectors (자기신호처리 적외선 감지소자의 온도효과를 고려한 해석적 모델)

  • 조병섭;곽계달
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.124-133
    • /
    • 1995
  • A theoretical self-consistent thermoelectric model has been developed for optimal thermal design in the self-signal processing infraed detectors. The model is achived by employing the coupled thermoelectric equation which allows which allows the simultaneous investigation of the termal and electrical aspects of device behavior. The thermal limitation of detectivity and responsivity are determined by the enegy gap, carrier concentration, lifetime, and mobility as a function of the temperature. The calculated results indicate that the detectivity is decreased at bias fields above about 50 V/cm, because the performence is limiting by temperature when the bias voltage reached the level associated with Joule heating. It has been also found that the improvement in the mid-band modulation transfer function(MTF) may be restricted by increasing the bias fields. Further, the important paramerers in the thermal optimization of SPIR detector, such as temperature in the device, ambipolar velocity, element thickness and length, are also considered. The analytical study provides a mathematical basis for optimal design of such a photoconductive IR detector and the agreement between the experimental and theoretical results are seen to be good.

  • PDF

Determination of Residual Pesticides in Recycle Product of Waste Plastic Pyrolysis (폐비닐 열분해 재활용품 중의 잔류농약 분석)

  • Shin Hea Soon;Shim Sung Hoon
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.3
    • /
    • pp.315-320
    • /
    • 2004
  • Environmental waste treatment technology is transforming from incineration system to pyrolysis gasification system. And there it is necessary for our country to adapt gasification system urgently to prevent the land pollution and lack of landfill area. The objective of this study was to determine the pesticides residues of derived product of pyrolysis gasification system for recycling of waste plastic by gas chromatograph-mass selective detector and nitrogen phosphorus detector. The residual pesticides were not detected in derived product of waste recyling. But some pesticide was detected on raw level (0.02 ~ 0.05 ppm) in waste plastic sample.