• 제목/요약/키워드: length measurement

검색결과 2,207건 처리시간 0.031초

인태제작을 위한 인체계측과 집락구조분석 (Anthropometry and Cluster Analysis for Figure Construction)

  • 문성혜;심부자
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.151-162
    • /
    • 1991
  • The purpose of this study was to examine the point at issue unfitness and unclassification in figures for clothing construction. Comparing measurements of 3 sold figures and physical body by Suck·Go method and 19 items were selected. These items were acquired by factor analysis and cluster analysis an measurements of 200 women in twenties. The results were as follows; 1. Comparison between measurement of figures and physical body; There was not so much difference among figures, but significant difference between figures and physical body. 2. Comparison between measurement of surface area of figures and physical body; There was similar to each figure, but significant difference between figures and physical body. Mostly, figures were bigger than physical body in front parts but smaller in back parts. 3. There were 8 items selected by factor analysis; That is bust girth, waist girth, hip girth, neck base girth, posterior waist length, bust point length, chest breadth and armscye girth. 4. There were 7 clusters selected by cluster analysis.

  • PDF

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권5호
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

측정점 교환방식 미세입자 모니터링 시스템 고도화 (Advancement of Sequential Particle Monitoring System)

  • 안성준
    • 반도체디스플레이기술학회지
    • /
    • 제21권1호
    • /
    • pp.17-21
    • /
    • 2022
  • In the case of the manufacturing industry that produces high-tech components such as semiconductors and large flat panel displays, the manufacturing space is made into a cleanroom to increase product yield and reliability, and various environmental factors have been managed to maintain the environment. Among them, airborne particle is a representative management item enough to be the standard for actual cleanroom grade, and a sequential particle monitoring system is usually used as one parts of the FMS (Fab or Facility monitoring system). However, this method has a problem in that the measurement efficiency decreases as the length of the sampling tube increases. In this study, in order to solve this problem, a multiple regression model was created. This model can correct the measurement error due to the decrease in efficiency by sampling tube length.

와이어 병렬 메카니즘에 의한 로봇의 완전 자세 측정 (Full Pose Measurement of a Robot by the Wire Parallel Mechanism)

  • 정재원;김수현;곽윤근
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.134-142
    • /
    • 1997
  • In this study, we proposed the wire parallel mechanism that can be used to measure a full pose of a robot. It is composed of six parallel links using wire. The position and orientation of the end effectorf of a robot are calculated using the length of wires which is measured by the encoder. The complex non- linear equations of the forward kinematics are solved by using a numerical method, and the unique solution is obtained from the geometric configuration of the device. The length error of the wire which occurs in static condition is compensated by the relational equation that considered longitudinal extension and defoection of the wire. Through this work, we known that the proposed device has a good accuracy( .+-. 0.01mm) in a large measuring region, so it can be used effectively in a callibration of a robot which required a low cost.

  • PDF

레이저의 간섭무늬를 이용한 리니어 엔코더에 관한 연구 (High resolution Linear Encoder Using Interference Fringe)

  • 박윤창
    • 한국생산제조학회지
    • /
    • 제8권4호
    • /
    • pp.130-135
    • /
    • 1999
  • The main scale of linear encoder greatly effects on the precision of displacement measurement. Especially when needing the long range measurement the length of main scale should be increased accordingly. In this paper we propose a linear encoder that uses laser interference pattern as main scale for long range measurement. The linear encoder is similar to Michelson interferometer excepting that the reference mirror is tilted so as to obtain interference fringe pattern and a grating panel is attached on a quadratic photo diodes. Four kinds of grating having phase difference of 0. $\pi$/4, $\pi$/2, 3$\pi$/4 are arranged on the panel. The experimental results show that signals of quadratic photo diode A, B, {{{{ {-}atop {A } }}}} and {{{{ {- } atop {B } }}}} are cosine wavelike and successive signals have phase difference of $\pi$/4 each other. So the proposed method can achieve improved measurement resolution.

  • PDF

하천유량 측정기법에 관한 연구 (A Study on the River Discharge Measurement Techniques)

  • 김성원;지홍기
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

A Development of Recoil & Counter Recoil Motion Measurement System Using LVDT

  • Park, Ju-Ho;Hong, Sung-Soo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권3호
    • /
    • pp.214-219
    • /
    • 2000
  • This paper presents a recoil and counter recoil motion measurement system using linear variable differential transformers (LVDT). The output of the LVDT is obtained from the differential voltage of the secondary transformers. Since a transducer core is attached to the motion body, the output is directly proportional to the movement length of the core. Displacement, velocity and acceleration are measured from the LVDT. With a comparison between the measurement result and the reference value obtained by the highly accurate Vernier calipers, it is proved that the measurement system with the LVDT is applicable to the test of the moving part of the mechanism with better accuracy.

  • PDF

스캐폴딩 집단유형 및 능력수준에 따른 역동적 평가과정이 유아의 측정능력에 미치는 영향 (The Effects of Dynamic Assessment in Terms of Scaffolding Group Types and Young Children's Measurement Ability Levels)

  • 고은미;남미경;황해익
    • 아동학회지
    • /
    • 제30권5호
    • /
    • pp.225-243
    • /
    • 2009
  • This study analyzed the effects of dynamic assessment in terms of scaffolding group types and young children's measurement ability levels. Participants were five-year-old children in Busan divided into 2 experimental groups and control groups. The Assessment Tools for Young Children's Measurement Ability (Ko & Hwang, 2008) consisted of 4 sub tests for ‘length', 'width', and 'weight' concepts. Data were analyzed by t-test and ANOVA. Results showed significant differences between experimental and control groups in post-test scores, but no significant differences between individual and peer collaboration groups in amount of scaffolding. Significant improvements showed in all of the measurement ability level groups : individual higher, individual lower, peer collaboration higher and peer collaboration lower level scaffolding groups.

  • PDF

Buried Channel MOS 구조를 이용한 표면생성속도 측정 방법 (A Surface Generation Velocity Measurement Technique Using the Buried Channel MOS Structure)

  • 조성호;허연철;이종덕
    • 전자공학회논문지A
    • /
    • 제29A권7호
    • /
    • pp.56-63
    • /
    • 1992
  • A measurement technique of the surface generation velocity S$_o$ using the BC(buried channel) MOS structure with shallow and low doped channel layer (BC MOS S$_o$ measurement technique) is presented and verified analytically and experimentally. Using this measurement technique, S$_o$ can be measured more accurately than that measured using the gate-controlled diode SS1oT measurement technique. When S$_o$ is measured for the two techniques from a BC MOS structure test patten with gate length of 171$\mu$m, the results are 0,66cm/sec and 0.28cm/sec for the former and the latter respectively.

  • PDF

ALC 블록의 높이와 길이 측정을 위한 자동 비전 검사 시스템 개발 (Development of Automatic Inspection System for Altitude and Length Measurement of ALC Block)

  • 엄주진;허경무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.661-664
    • /
    • 2003
  • This paper presents a computer image processing system, which inspects the measurement of the ALC block on a real-time basis. The Image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by the system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. From the experimental results, we could find that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

  • PDF