• Title/Summary/Keyword: leakage problems

Search Result 545, Processing Time 0.023 seconds

Assembly Analysis for Evaluation of Sealing in PEMFC Stack (고분자 전해질 연료전지 스택의 시일링 평가를 위한 체결 해석)

  • Kim, Dae-Young;Kim, Jung-Min;Kim, Heon-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.68-75
    • /
    • 2010
  • The one of the major problems in the development of PEMFC was regarding to the assurance of sealing on stack. The failure on the sealing creates the problems of fuel leakage, mixing, internal combustion, damage on parts and can be a direct reason for the degrading the efficiency of fuel cell. This paper studies on the analytical approach for improving the contacting pressure distribution on the gasket at the evaluation on the sealing of fuel cell stack. So, the assembly analysis on multi layered fuel cell stack was performed. The research on the simplification of finite element model was performed for three dimensional analysis at the multi layered state. The improved contact pressure distribution was obtained through the case studies on gasket for better sealing. In addition, the number of the cell was determined for the effective analysis and the structural characteristics were evaluated based on this research.

Analysis of Personal Information Protection System in Korea - Focus on Certification & Evauation System and Personal Identification Number - (우리나라의 개인정보 보호제도 분석 - 인증 및 평가제도와 개인식별번호를 중심으로 -)

  • Kim, Min-Chen
    • Informatization Policy
    • /
    • v.23 no.4
    • /
    • pp.38-58
    • /
    • 2016
  • The ever-evolving Internet environment along with changes in the mass media has been creating a new way of communicating in the virtual cyber world. The Internet users have more services at their disposal to communicate with ease. Such a new way of communication styles, however, makes them vulnerable to personal information leakage, increasing the concerns of cyber security. A thorny issue is how we can control the disclosure of personal information. Lately, the Korean government implemented privacy policies to resolve and prevent personal information leakage incidents that incur social problems. Here, we seek to identify problems in the privacy policies for better solutions.

A study on the Development of an Eco-friendly Rooftop Waterproofing Method (친환경 옥상방수공법 개발에 관한 연구)

  • Oh, Dong-Sik;Go, Seong-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.103-111
    • /
    • 2010
  • This research aims to make a contribution to the development of waterproofing technique for rooftops by analyzing and understanding the problems of the currently used waterproofing method and their causes. To do this, this research developed an eco-friendly waterproofing method that supplements the weaknesses of the conventionally used method by analyzing the problems of leakage resulting from design and construction work to diminish leakage, improving the quality of construction work, reducing labor required and the period of construction, and improving environment alconditions. The characteristics of the newly developed method are comparatively analyzed with the convention alpractices, and are evaluated on the site.

Field Application of Up-Up Construction Using Buried Wale Continuous Walt System Method (CWS공법(Buried Wale Continuous Wall System)을 적용한 Up-Up 시공사례)

  • Lee Jeong-Bae;Lim In-Sig;Kim Dong-Hyun;Oh Bo-Hwan;Ha In-Ho;Rhim Hong-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.1-4
    • /
    • 2006
  • A down construction method is frequently used in these days to reduce popular discontent and to assure sufficient working space at early stage in downtown area. There are two main problems in the existing down construction method. One is a confliction between frame works and excavation works, and the other is a cold joint in retaining wall which is unavoidable due to a sequence of concrete placement and induces a water leakage. Therefore, a new method is needed to overcome these problems. The CWS (buried wale Continuous Wall System) method was developed by authors. By replacing RC perimeter beam with embedded steel wale, the steel frame works of substructure can be simplified and the water leakage can be prevented using continuous retaining wall. Consequently, the improved duality and reduction of construction period can be obtained from CWS method.

  • PDF

Study on Development of CWS (buried wale Continuous Wall System) Method (CWS공법(buried wale Continuous Wall System)의 개발에 관한 연구)

  • Lee Jeong-Bae;Lim In-Sig;Chun Sung-Chul;Oh Boh-Wan;Ha In-Ho;Rhim Hong-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.2 s.20
    • /
    • pp.81-89
    • /
    • 2006
  • A down construction method is frequently used in these days to reduce popular discontent and to assure sufficient working space at early stage in downtown area. There are two main problems in the existing down construction method. One is a confliction between frame works and excavation works, and the other is a cold joint in retaining wall which is unavoidable due to a sequence of concrete placement and induces a water leakage. Therefore, a new method is needed to overcome these problems. The CWS (buried wale Continuous Wall System) method was developed by authors. By replacing RC perimeter beam with embedded steel wale, the steel frame works of substructure can be simplified and the water leakage can be prevented using continuous retaining wall. Consequently, the improved qualify and reduction of construction period can be obtained from CWS method.

Experimental Parametric Study on the Rotordynamic Characteristics and Optimal Design of a Flexible Rotor Supported by a Slotted-Ring Electro-Rheological Squeeze Film Damper (슬롯 링 형상을 갖는 전기 유변 스퀴즈 필름 댐퍼로 지지된 연성 로터의 동특성 및 최적설계 파라미터 실험 연구)

  • 이용복;김창호;이남수;최동훈;정시영
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.157-165
    • /
    • 2000
  • A discharge free Electro-Rheological Squeeze Film Damper (ER-SFD) with predetermined-clearances at leakage ends can inherently eliminate electric discharge problems while still supplying stable leakage control. Test results show that the damping force of the slotted-ring ER-SFD is mainly affected by electric voltage, oil supply pressure, position of the damper and ratio of effective surface area of slotted-rings. As the supply voltage is larger, the amplitudes of both slotted ER-SFD and rotor are decreased at first and second critical speeds. The influence of the oil supply pressure and the effective surface area ratio was shown mainly near the first critical speed. The effective surface area ratio of slotted-rings influences the reduction of flexible rotor vibration. As a result, experimental results confirm that the slotted-ring ER-SFD satisfactorily controls the flexible rotor vibration, while eliminates the inherent electric discharge problems in conventional ER-SFDs.

Tracking/Erosion Resistance Analysis of Nano-Al(OH)3 Filled Silicone Rubber Insulating Materials for High Voltage DC Applications

  • Kannan, P.;Sivakumar, M.;Mekala, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.355-363
    • /
    • 2015
  • HVDC technology has become popular as an economic mode of bulk power transmission over very long distances. Polymeric insulators in HVDC power transmission lines are affected by surface tracking and erosion problems due to contamination deposit, which pose a greater challenge in maintaining the reliability of the HVDC system. In addition, polymeric insulators are also naturally affected by aging due to various environmental stresses, which in turn accelerates the surface tracking and erosion problems. Research works towards the improvement of tracking and erosion resistance of polymeric insulators by adding nano-sized fillers in the base material are being carried out worldwide. However, surface tracking and erosion performance of nano-filled aged polymeric insulators for HVDC applications are not well reported. Hence, in the present work, tracking and erosion resistance of the nano $Al(OH)_3$ filled silicone rubber insulation material has been evaluated under DC voltages at different filler concentrations and aged conditions, as per IEC 60587 test procedures. Leakage current and contact angle measurements were carried out to understand the surface hydrophobicity. Moving average technique was used to analyze the trend followed by leakage current. Water aged specimen shows less tracking resistance when compared with thermal aged specimen. It is observed that nano-filler concentration of 5% is even sufficient to get better tracking/erosion resistance under DC voltages.

A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (2) (필댐의 안정성 해석 연구 (II))

  • HoWoongShon;DaeKeunLee
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.189-207
    • /
    • 2003
  • The purpose of this paper is to analyze the behavior and to study the safety evaluation of the Unmun Dam located in Cheongdo-Gun of GyeongBuk Province, Korea. For this purpose, soil analyses including boring data, geophysical surveys and monitoring the buried geotechnical gauges, such as pore-pressure gauge, earth-pressure gauge, displacement gauge, multi-layer settlement gauge, leakage flow-meter, were conducted. In addition to these data, numerical analyses of behavior of dam were performed to predict and to compare the data which were obtained from the above methods. Since many defects, such as gravel and weathered rock blocks in the dam core, and lots of amounts of leakage, by boring analyses were found, reinforcement by compaction grouting system (CGS) has been conducted in some range of dam. Some geotechnical gauge data were also used to confirm the effects of reinforcement. Analyses of monitoring the data of geotechnical gauges buried in the dam, such as pore-pressure gauge, earth-pressure gauge, displacement gauge, multi-layer settlement gauge, and leakage flow-meter shows the load transfer of dam and the possibility of hydraulic fracturing. As a conclusion, some problems in the dam found. Especially, the dam near spillway shows the high possibility of leakage. It should be pointed out that only the left side of he dam has not a leakage problem. As a whole, the dam has problems of weakness, because of unsatisfactory construction. It is strongly recommended that highly intensive monitoring is required.

  • PDF

A Study on the Policy Measures for the Prevention of Industrial Secret Leakage in the Metaverse (메타버스 내 산업기밀 유출 대응을 위한 정책 및 제도에 관한 연구)

  • Jeon, So-Eun;Oh, Ye-Sol;Lee, Il-Gu
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.377-388
    • /
    • 2022
  • Metaverse, realistic virtual space technology has become a hot topic. However, due to the lack of an institutional system to the metaverse environment, concerns are rising over the leakage of industrial confidentiality, including digital assets produced, stored, processed, and transferred within the metaverse. Digital forensics, a technology to defend against hacking attacks in cyberspace, cannot be used in metaverse space, and there is no basis for calculating the extent of damage and tracking responsibility, making it difficult to respond to human resources leakage and cyberhacking effectively. In this paper, we define the scope of industrial confidentiality information and leakage scenario and propose policy and institutional measures based on problems in each metaverse scenario. As a result of the study, it was necessary to prepare a standardized law on Extra-territorial search and seizure issues and a system for collecting cryptocurrency evidence to respond to industrial confidentiality leaks in the metaverse. The study expects to contribute to industrial technology development by preparing in advance for problems that may arise in metaverse technology.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.