• Title/Summary/Keyword: layout design

Search Result 1,728, Processing Time 0.027 seconds

Design of PMOS-Diode Type eFuse OTP Memory IP (PMOS-다이오드 형태의 eFuse OTP IP 설계)

  • Kim, Young-Hee;Jin, Hongzhou;Ha, Yoon-Gyu;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.1
    • /
    • pp.64-71
    • /
    • 2020
  • eFuse OTP memory IP is required to trim the analog circuit of the gate driving chip of the power semiconductor device. Conventional NMOS diode-type eFuse OTP memory cells have a small cell size, but require one more deep N-well (DNW) mask. In this paper, we propose a small PMOS-diode type eFuse OTP memory cell without the need for additional processing in the CMOS process. The proposed PMOS-diode type eFuse OTP memory cell is composed of a PMOS transistor formed in the N-WELL and an eFuse link, which is a memory element and uses a pn junction diode parasitic in the PMOS transistor. A core driving circuit for driving the array of PMOS diode-type eFuse memory cells is proposed, and the SPICE simulation results show that the proposed core circuit can be used to sense post-program resistance of 61㏀. The layout sizes of PMOS-diode type eFuse OTP memory cell and 512b eFuse OTP memory IP designed using 0.13㎛ BCD process are 3.475㎛ × 4.21㎛ (= 14.62975㎛2) and 119.315㎛ × 341.95㎛ (= 0.0408mm2), respectively. After testing at the wafer level, it was confirmed that it was normally programmed.

Design of Synchronous 256-bit OTP Memory (동기식 256-bit OTP 메모리 설계)

  • Li, Long-Zhen;Kim, Tae-Hoon;Shim, Oe-Yong;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1227-1234
    • /
    • 2008
  • In this paper is designed a 256-bit synchronous OTP(one-time programmable) memory required in application fields such as automobile appliance power ICs, display ICs, and CMOS image sensors. A 256-bit synchronous memory cell consists of NMOS capacitor as antifuse and access transistor without a high-voltage blocking transistor. A gate bias voltage circuit for the additional blocking transistor is removed since logic supply voltage VDD(=1.5V) and external program voltage VPPE(=5.5V) are used instead of conventional three supply voltages. And loading current of cell to be programmed increases according to RON(on resistance) of the antifuse and process variation in case of the voltage driving without current constraint in programming. Therefore, there is a problem that program voltage can be increased relatively due to resistive voltage drop on supply voltage VPP. And so loading current can be made to flow constantly by using the current driving method instead of the voltage driving counterpart in programming. Therefore, program voltage VPP can be lowered from 5.9V to 5.5V when measurement is done on the manufactured wafer. And the sens amplifier circuit is simplified by using the sens amplifier of clocked inverter type instead of the conventional current sent amplifier. The synchronous OTP of 256 bits is designed with Magnachip $0.13{\mu}m$ CMOS process. The layout area if $298.4{\times}314{\mu}m2$.

A Design of Digital CMOS X-ray Image Sensor with $32{\times}32$ Pixel Array Using Photon Counting Type (포톤 계수 방식의 $32{\times}32$ 픽셀 어레이를 갖는 디지털 CMOS X-ray 이미지 센서 설계)

  • Sung, Kwan-Young;Kim, Tae-Ho;Hwang, Yoon-Geum;Jeon, Sung-Chae;Jin, Seung-Oh;Huh, Young;Ha, Pan-Bong;Park, Mu-Hun;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.7
    • /
    • pp.1235-1242
    • /
    • 2008
  • In this paper, x-ray image sensor of photon counting type having a $32{\times}32$ pixel array is designed with $0.18{\mu}m$ triple-well CMOS process. Each pixel of the designed image sensor has an area of loot $100{\times}100\;{\mu}m2$ and is composed of about 400 transistors. It has an open pad of an area of $50{\times}50{\mu}m2$ of CSA(charge Sensitive Amplifier) with x-ray detector through a bump bonding. To reduce layout size, self-biased folded cascode CMOS OP amp is used instead of folded cascode OP amp with voltage bias circuit at each single-pixel CSA, and 15-bit LFSR(Linear Feedback Shift Register) counter clock generator is proposed to remove short pulse which occurs from the clock before and after it enters the counting mode. And it is designed that sensor data can be read out of the sensor column by column using a column address decoder to reduce the maximum current of the CMOS x-ray image sensor in the readout mode.

A Charge Pump Design with Internal Pumping Capacitor for TFT-LCD Driver IC (내장형 펌핑 커패시터를 사용한 TFT-LCD 구동 IC용 전하펌프 설계)

  • Lim, Gyu-Ho;Song, Sung-Young;Park, Jeong-Hun;Li, Long-Zhen;Lee, Cheon-Hyo;Lee, Tae-Yeong;Cho, Gyu-Sam;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1899-1909
    • /
    • 2007
  • A cross-coupled charge pump with internal pumping capacitor, witch is advantages from a point of minimizing TFT-LCD driver IC module, is newly proposed in this paper. By using a NMOS and a PMOS diode connected to boosting node from VIN node, the pumping node is precharged to the same value each pumping node at start pumping operation. Since the lust-stage charge pump is designed differently from the other stage pumps, a back current of pumped charge from charge pumping node to input stage is prevented. As a pumping clock driver is located the font side of pumping capacitor, the driving capacity is improved by reducing a voltage drop of the pumping clock line from parasitic resistor. Finally, a layout area is decreased more compared with conventional cross-coupled charge pump by using a stack-MIM capacitors. A proposed charge pump for TFT-LCD driver IC is designed with $0.13{\mu}m$ triple-well DDI process, fabricated, and tested.

Transforming a Buffer Green into an Urban Park as Multi-functional Green Infrastructure - A Case of the Buffer Green of Sinmae Market in Daegu, Korea - (입체적 도시기반시설로서 완충녹지의 공원화 계획 - 대구광역시 신매시장 완충녹지 공원화 계획을 사례로 -)

  • Kim, Miyeun;Min, Byoungwook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.2
    • /
    • pp.101-112
    • /
    • 2021
  • In Korea, efforts have been made continuously to improve the environment of traditional markets concerning the issues of urban regeneration. In particular, many old cities and traditional markets face a lack of parking spaces. As a solution to this, attempts are being made to prepare underground parking spaces by designing urban planning facilities in three-dimensional ways and utilizing the upper part as a more meaningful space. This study is about the master plan to use the upper green area while creating an underground parking lot at 571 Sinmae-dong, Suseong-gu, Daegu. This green area was defined as a space with dual values, 'defensive green space' that needs to be ecologically protected, and 'active cultural space' where walking flows to the market and various events are concentrated. Three specific design strategies to balance these values were presented. First, to prevent indiscriminate occupation and damage by people and maintain a healthy green environment, securing the maximum amount of undivided green space in the site was suggested. Second, a space layout and a topography and planting patterns that can overcome the morphological characteristics of narrow and long-shaped sites enable the experience of abundant green spaces. Third, providing space to strengthen the connections with nearby urban facilities such as Sinmae Market and Gosan Library can also intensively accommodate cultural activities in various cities. This study has academic significance in providing implications for urban regeneration projects with similar contexts in the future.

Analysis of Emission Characteristics of DC/DC Converter with different Parts Layout (부품배치가 다르게 제작된 DC/DC컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.179-183
    • /
    • 2019
  • The system stability must be ensured from the switching noise due to the power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. Thus, in the previous paper, we constructed the DC / DC Buck Converter circuit using MPQ4432 driver of MPS, and simulated the switching noise characteristics which occurs when the components are arranged differently in the 4 - layer PCB circuit structure with reference plane. In this paper, two different simulated circuits are fabricated and the characteristics of the conducted emission and the radiated emission are analyzed in the same way as the simulation. As a result, it was confirmed that the Conducted Emission characteristic was reduced by 2 ~ 9dB in the low frequency band and 6 ~ 7dB in the high frequency band depending on the configuration of the current return path. And the radiated emission characteristic is reduced by 9 dB. Conducted emission simulation results show that 6 ~ 7dB in the low frequency range and 2 ~ 9dB in the measurement result are somewhat different. In the high frequency band, it is confirmed that the experimental and simulation results are about 7dB. And Radiated Emission confirmed 12dB decrease in simulation, but confirmed decrease of 9dB in measurement result. It is confirmed that there is a slight difference in the amount of reduction, but the design of the power conversion circuit improves the noise characteristics according to the configuration of the current return path.

Appropriate level of alfalfa hay in diets for rearing Simmental crossbred calves in dryland China

  • Kobayashi, Nobuyuki;Hou, Fujiang;Tsunekawa, Atsushi;Chen, Xianjiang;Yan, Tianhai;Ichinohe, Toshiyoshi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.12
    • /
    • pp.1881-1889
    • /
    • 2018
  • Objective: In dryland areas of China, alfalfa hay (AH) is a possible substitute for concentrate feed for beef cattle. To evaluate the potential benefits of this substitution, we studied the effect of the ratio of AH intake to total dry matter (DM) intake on average daily body-weight gain (ADG), dietary energy utilization status, and economic benefit in Gansu province. Methods: In each of two feeding trials in 2016 (trial 1 [T1], July 3 to 17; trial 2 [T2], August 15 to September 23), crossbred male Simmental calves were allocated to low AH (LA), medium AH (MA), and high AH (HA) feeding groups (n = 4 per group). The target ADG was set as 1 kg for both trials. In a one-way-layout design based on conventional feeding practices in the province, calves received diets containing the different AH amounts, with a constant ratio of corn stover:total DM and decreasing rations of concentrate feed proportional to the increase in AH. Calves in T1 received AH at 15% (T1-LA), 23% (T1-MA), or 31% (T1-HA) of their dietary DM allowances; those in T2 received 9% (T2-LA), 24% (T2-MA), or 34% (T2-HA) AH. Results: Among the T1 groups, both ADG and economic benefit were highest in T1-LA; whereas in T2, they were higher in the T2-LA and T2-MA groups than in T2-HA. Energy digestibility did not significantly differ among the groups in either trial. The dietary AH inclusion ratios of 14% in the warm season and 8% to 21% in the cool season appeared to yield optimal ADG, metabolizable energy intake, and economic benefit. Conclusion: Low-level inclusion of AH, ranging from 8% to 21%, is a practical approach for beef cattle feeding. This modified feeding regimen likely will promote increased growth performance during the fattening stage of beef steers in dryland areas of Gansu province, China.

Cellular Automata Simulation System for Emergency Response to the Dispersion of Accidental Chemical Releases (사고로 인한 유해화학물질 누출확산의 대응을 위한 Cellular Automata기반의 시뮬레이션 시스템)

  • Shin, Insup Paul;Kim, Chang Won;Kwak, Dongho;Yoon, En Sup;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • Cellular automata have been applied to simulations in many fields such as astrophysics, social phenomena, fire spread, and evacuation. Using cellular automata, this study develops a model for consequence analysis of the dispersion of hazardous chemicals, which is required for risk assessments of and emergency responses for frequent chemical accidents. Unlike in cases of detailed plant safety design, real-time accident responses require fast and iterative calculations to reduce the uncertainty of the distribution of damage within the affected area. EPA ALOHA and KORA of National Institute of Chemical Safety have been popular choices for these analyses. However, this study proposes an initiative to supplement the model and code continuously and is different in its development of free software, specialized for small and medium enterprises. Compared to the full-scale computational fluid dynamics (CFD), which requires large amounts of computation time, the relative accuracy loss is compromised, and the convenience of the general user is improved. Using Python open-source libraries as well as meteorological information linkage, it is made possible to expand and update the functions continuously. Users can easily obtain the results by simply inputting the layout of the plant and the materials used. Accuracy is verified against full-scale CFD simulations, and it will be distributed as open source software, supporting GPU-accelerated computing for fast computation.

A Study of Stone Sculptures of Jagneung and Sareung - The Reinstatement and Stone Sculpture Simplification - (장릉(莊陵)과 사릉(思陵)의 석물 연구 - 추봉과 석물 간소화를 중심으로 -)

  • Kim, Yi Soon
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.1
    • /
    • pp.34-51
    • /
    • 2012
  • Jangneung (the Royal Tomb of King Danjong) and Sareung (the Royal Tomb of Queen Jeongsun) are simple in their design and layout. Not only are the sizes of the stone statues small, but stone soldiers are not installed at all despite the fact that Danjong at one point served as the King of Joseon. Moreover, only a pair of seoksu (stone animal) is installed for each Tomb. These royal tombs were originally made as common tombs and later upgraded as Royal Tombs when Danjong's royal status was reinstated posthumously in 1698. Thus, in comparison to royal tombs in general, the scale of these tombs is by far modest. For this paper, archival records and other literature for the burial upgrade process and the stone sculptures are examined; also, the stone sculptures have been examined and measured on-site, and they have been compared and analyzed based on the data thus obtained. Furthermore, this paper traces the historical context of the period in which the simplification of the stone sculptures took place for Jangneung and Sareung. The paper argues that the cause of the modest scale lies not so much in the fact that King Danjong had been dethroned as a commoner, but in the cataclysmic famine and epidemic that swept the country during the time when the two royal tombs were upgraded as such.

Design and Implementation of IP Video Wall System for Large-scale Video Monitoring in Smart City Environments (스마트 시티 환경에서 대규모 영상 모니터링을 위한 IP 비디오 월 시스템의 설계 및 구현)

  • Yang, Sun-Jin;Park, Jae-Pyo;Yang, Seung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.7-13
    • /
    • 2019
  • Unlike a typical video wall system, video wall systems used for integrated monitoring in smart city environments should be able to display various videos, images, and texts simultaneously. In this paper, we propose an Internet Protocol (IP)-based video wall system that has no limit on the number of videos that can be monitored simultaneously, and that can arrange the monitor screen layout without restrictions. The proposed system is composed of multiple display servers, a wall controller, and video source providers, and they communicate with each other through an IP network. Since the display server receives and decodes the video stream directly from the video source devices, and displays it on the attached monitor screens, more videos can be simultaneously displayed on the entire video wall. When one video is displayed over several screens attached to multiple display servers, only one display server receives the video stream and transmits it to the other display servers by using IP multicast communications, thereby reducing the network load and synchronizing the video frames. Experiments show that as the number of videos increases, a system consisting of more display servers shows better decoding and rendering performance, and there is no performance degradation, even if the display server continues to be expanded.