• 제목/요약/키워드: laser Doppler

검색결과 480건 처리시간 0.03초

Laser Doppler Flowmetry를 이용한 유리치은이식술 부위의 치은혈류 변화에 관한 연구 (A study on gingival blood flow change of free gingival graft sites using Laser Doppler Flowmetry)

  • 전동영;박병기;염창엽;김세훈;김재덕;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.291-302
    • /
    • 2002
  • In most of the previous studies, invasive and discrete techniques have been used to monitor the healing process of the gingival graft. However, Laser Doppler Flowmetry(LDF, floLAB(R), Moor Instruments Ltd., England) is a non-invasive technique for measurement of blood flow in the tissue and also allows continuous monitoring. Thus, we tested the usefulness of LDF in monitoring the healing process of free gingival graft at gingival recession. Eleven gingival graft site of 7 patients, including 5 males and 2 females, aged between 21 and 41 years (mean age 28.5) were monitored for the blood flow. The blood flow in gingival graft at coronal site, central site, apical site, mesial site and distal site was measured using LDF. Blood flow was measured at 1- week, 2- week, 3- week and 4- week after gingival graft surgery from 10 a.m. to 2 p.m. Time-course of the healing process was evaluated by statistical analysis using repeated ANOVA and Duncan test. The results were as follows : (1) Blood flow stayed increased for 2 weeks, and then, it was a tendency to decrease. (2) The blood flow at distal site had always higher than mesial site during the measuring periods. (3) The blood flow was high orderly after 1 week ; most coronal site, most apical site, central site. But that was high orderly after 2 week, 3 week, 4 week ; most coronal site, central site, most apical site. In conclusion, LDF was a useful and clinically adaptable method to monitor wound healing process. Our study suggested that it was important to protect surgical site to promote initial wound healing.

레이저 도플러 원리를 이용한 유체 가속도 측정 (Effect of fringe divergence in fluid acceleration measurement using LDA)

  • 전세종;홀거노박;캠트로피아;성형진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1546-1551
    • /
    • 2004
  • The laser Doppler technique is well-established as a velocity measurement technique of high precision for flow velocity. Recently, the laser Doppler technique has also been used to measure acceleration of fluid particles. Acceleration is interesting from a fluid mechanics point of view, since the Navier Stokes equations, specifically the left-hand-side, are formulated in terms of fluid acceleration. Further, there are several avenues to estimating the dissipation rate using the acceleration. However such measurements place additional demands on the design of the optical system; in particular fringe non-uniformity must be held below about 0.0001 to avoid systematic errors. Relations expressing fringe divergence as a function of the optical parameters of the system have been given in the literature; however, direct use of these formulae to minimize fringe divergence lead either to very large measurement volumes or to extremely high intersection angles. This dilemma can be resolved by using an off-axis receiving arrangement, in which the measurement volume is truncated by a pinhole in front of the detection plane. In the present study an optical design study is performed for optimizing laser Doppler systems for fluid acceleration measurements. This is followed by laboratory validation using a round free jet and a stagnation flow, two flows in which either fluid acceleration has been previously measured or in which the acceleration is known analytically. A 90 degree off-axis receiving angle is used with a pinhole or a slit.

  • PDF

생체 청각기구를 모사한 폴리머 박막의 주파수 분리 특성 평가 (Characterization of Frequency Separation in Polymer Membranes Mimicking a Human Auditory System)

  • 송원준;배성재;김완두
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.516-521
    • /
    • 2011
  • 청각기관인 달팽이관에 존재하는 기저막의 중요한 기능은 등자뼈로부터 전달되는 진동에너지를 주파수별로 분리하는 것이다. 본 연구에서는 인간 기저막의 형상을 모사하여 설계한 매크로 스케일의 폴리머 박막을 사용하여 주파수 분리 특성을 연구하였다. 각각의 폴리머 박막상의 위치에 따른 변위 분포는 LDV (laser Doppler vibrometer) 스캐닝 기법을 이용하여 측정하였고, 측정된 결과는 후처리 과정을 거쳐 주파수별로 분리하였다. 인가된 주파수에 따른 최대 변위 발생 위치를 추출하여 각 박막에 대한 주파수-최대 변위 발생 위치 관계를 도식화하였다. 아울러 박막 두께 및 물성치가 주파수-최대 변위 발생 위치 관계에 미치는 영향에 대해서도 논하였다.

Steady-Flow Characteristics and Its Influence on Spray for Direct Injection Diesel Engine

  • Jeon, Chung-hwan;Park, Seung-hwan;Chang, Young-june
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.986-998
    • /
    • 2002
  • Flow and spray characteristics are critical factors that affect the performance and exhaust emissions of a direct injection diesel engine. It is well known that the swirl control system is one of the useful ways to improve the fuel consumption and emission reduction rate in a diesel engine. However, until now there have only been a few studies on the effect of flow on spray. Because of this, the relationship between the flow pattern in the cylinder and its influence on the behavior of the spray is in need of investigation. First, in-cylinder flow distributions for 4-valve cylinder head of DI (Direct Injection) Diesel engine were investigated under steady-state conditions for different SCV (Swirl Control Valve) opening angles using a steady flow rig and 2-D LDV (Laser Doppler Velocimetry). It was found that swirl flow was more dominant than that of tumble in the experimented engine. In addition, the in-cylinder flow was quantified in terms of swirl/tumble ratio and mean flow coefficient. As the SCV opening angle was increased, high swirl ratios more than 3.0 were obtained in the case of SCV -70° and 90°. Second, spray characteristics of the intermittent injection were investigated by a PDA (Phase Doppler Anemometer) system. A Time Dividing Method (TDM) was used to analyze the microscopic spray characteristics. It was found that the atomization characteristics such as velocity and SMD (Sauter Mean Diameter) of the spray were affected by the in-cylinder swirl ratio. As a result, it was concluded that the swirl ratio improves atomization characteristics uniformly.

난류 미분탄화염 내 입자거동에 관한 연구 (A Study on the Particle Behavior in Turbulent Pulverized Coal Flame)

  • 황승민
    • 대한환경공학회지
    • /
    • 제32권12호
    • /
    • pp.1111-1118
    • /
    • 2010
  • 비접촉법으로 유동장이나 온도, 화학종 농도의 계측이 가능한 레이저 응용 계측기술은 연소 메카니즘의 해명뿐만 아니라 수치해석 결과의 정당성을 입증하는 수단으로 최근 주목받고 있다. 본 연구에서는 레이저 도플러 유속계와 쉐도우 도플러 입자 분석계를 이용하여 난류 미분탄 화염 내 입자거동에 대하여 관찰하였다. 버너는 여러 광학계측을 용이하게 하기 위하여 대기개방형으로 하였으며, 실험실 규모의 안정된 난류 미분탄화염이 형성 가능한 소형 모델버너를 제작 하였다. 그 결과 미분탄 입자의 평균입경은 연소과정이 진행함에 따라 증가하는 경향을 나타내었다. 이러한 원인은 다수의 소입경의 미분탄 입자가 휘발분을 방출하여 연소반응에 의해 소실되기 때문이다. 또한 화염 중심부에서 미분탄 입자의 속도장은 입경의 크기에 크게 의존하지 않지만, 화염 외주부에서의 미분탄 입자의 속도장은 입경에 크게 의존하고 있음을 알 수 있다.

한대의 LSV 를 이용한 3 차원 진동측정방법 (Three-dimensional vibration measurement algorithm using one laser scanning vibrometer)

  • 김동규;송하준;박기환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.935-939
    • /
    • 2012
  • 3D vibration measurement is achieved using one laser scanning vibrometer(LSV) and Laser scanner(LS) by moving the LSV to three arbitrarily locations from the principle that vibration analysis based on the frequency domain is independent of the vibration signal based on time domain. The proposed system has the same effect as using three sets of LSVs. It has an advantage of reducing equipment costs. Analytical approach of obtaining in-plane and out-of-plane vibration of surface is introduced using geometrical relations between three LSV coordinates and vibration measured at three different locations.

  • PDF

재관류손상을 받은 가토의 이개 피판에서 레이저도플러에 의한 피판 생존의 예측 (The Predictive Value of Laser Doppler for Flap Survival)

  • 김석권;박정민;백창윤;정기환;이근철;정진숙;박주인;박병호
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.503-510
    • /
    • 2005
  • If we could predict the necrosis of the flap caused by reperfusion injury, we can minimize the necrosis of the flap by taking appropriate action before necrosis begins. In this study, we examined whether we can predict the survival of flap under reperfusion injury or not, by measuring laser doppler flow meter values. We divided the group into the control and experimental groups corresponding to 6, 8, 9, 10, and 12hours after reperfusion(hours after ligation of auricular central artery). In each group, we examined necrotic change, perfusion unit (PU), serum superoxide dismutase (SOD), glutathione peroxidase, angiography and pathologic findings. No necrosis was observed in the 6 and 8 hours group but 8, 18, 20 hours after ligation, necrosis was observed, Also in each of 9, 10 and 12 hours group (each group consisted of 20 flaps), necrosis were noted. According to the above data, the critical time of necrosis in the auricular skin flap model lies between about 8 to 9 hours. Comparing the PU between the necrosis and non-necrosis groups, the former group showed a mean 39.57 PU increase after 60 min of reperfusion, and the latter group showed a mean increase of 21.21 PU. We can conclude that better flow can dilute oxygen free radical into systemic circulation, and this means less injuries are caused on vessels. Our study implies that if blood flow increase is less than 30 PU, intensive care is needed to save the flap. Additionally, we found significant decrease of serum SOD and glutathione peroxidase in the necrotic group. Therefore, monitoring these serum markers will be helpful in predicting reperfusion injury and supplementing these enzymes could be helpful to save the flap. The laser doppler flow meter is thought to be helpful in clinical circumstances for evaluating the circulation of the flap after the operation. However, more accumulation of clinical studies should be necessary establishing useful clinical data.

Nanoparticle Contrast in Magneto-Motive Optical Doppler Tomography

  • Kim, Jee-Hyun;Oh, Jung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.99-104
    • /
    • 2006
  • We introduce a novel contrast mechanism for imaging superparamagnetic iron oxide (SPIO) nanoparticles (average diameter ${\sim}100nm$) using magneto-motive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect the nanoparticles flowing through a glass capillary tube. A solenoid cone-shaped ferrite core extensively increased the magnetic field strength ($B_{max}=1\;T,\;{\Delta}|B|^2=220T^2/m$) at the tip of the core and also focused the magnetic force on targeted samples. Nanoparticle contrast was demonstrated in a capillary tube filled with the SPIO solution by imaging the Doppler frequency shift which was observed independent of the flow rate and direction. Results suggest that MM-ODT may be a promising technique to enhance SPIO nanoparticle contrast for imaging fluid flow.

The Effect of Second Order Refraction on Optical Bubble Sizing in Multiphase Flows

  • Qiu, Huihe;Hsu, Chin-Tsau;Liu, Wei
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1801-1807
    • /
    • 2001
  • In multiphase flne the bubble size and velocity. To achieve this, one of approaches is to utilize laser phase-Doppler anemometry. However, it was found that the second order refraction has great impact on PDA sizing method when the relative refractive index of media is less than one. In this paper, the problem of second order refraction is investigated and a model of phase-size correlation to eliminate the measurement errors is introduced for bubble sizing. As a result, the model relates the assumption of single scattering mechanism in conventional phase-Doppler anemometry. The results of simulations based on this new model by using Generalized Lorenz Mie Theory (GLMT) are compared with those based on the conventional method. An optimization method for accurately sizing air-bubble in water has been suggested.

  • PDF

Diagnostics of Magnetron Sputtering Plasmas: Distributions of Density and Velocity of Sputtered Metal Atoms

  • Sasaki, Koichi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.98-99
    • /
    • 2012
  • Deposition of thin films using magnetron sputtering plasmas is a well-developed, classical technology. However, detailed investigations using advanced diagnostics are insufficient in magnetron sputtering, in comparison with plasma-aided dry etching and plasma-enhanced chemical vapor deposition. In this talk, we will show examples of diagnostic works on magnetron sputtering employing metal targets. Diagnostic methods which have fine spatial resolutions are suitable for magnetron sputtering plasmas since they have significant spatial distributions. We are using two-dimensional laser-induced fluorescence spectroscopy, in which the plasma space is illuminated by a tunable laser beam with a planer shape. A charge-coupled device camera with a gated image intensifier is used for taking the picture of the image of laser-induced fluorescence formed on the planer laser beam. The picture of laser-induced fluorescence directly represents the two-dimensional distribution of the atom density probed by the tunable laser beam, when an intense laser with a relatively wide line-width is used. When a weak laser beam with a relatively narrow linewidth is used, the laser-induced fluorescence represents the density distribution of atoms which feel the laser wavelength to be resonant via the Doppler shift corresponding to their velocities. In this case, we can obtain the velocity distribution function of atoms by scanning the wavelength of the laser beam around the line center.

  • PDF