2중 상정고장시 대규모 전력계통으로부터 분리된 소규모 전력계통 과도안정도 분석 (An analysis of transient stability for small scale power system separated from large scale power system at N-2 contingency)

  • 윤기섭;백승도;구성완;이종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.134-135
    • /
    • 2003
  • Abstract in case of the small scale power system separated from large scale power system N-2 contingency, the Over excitation, Under Frequency and Power swing Tripping Relay operate depending on unbalance Of Generation and Load. and then we studied and measured the angle and frequency deviation between generators. moreover, we compared real fault example with simulation results.

  • PDF

TCP의 다중 시간 간격에서 선택적 기울기 제어를 이용한 혼잡 제어 (The Congestion Control using Selective Slope Control under Multiple Time Scale of TCP)

  • 김광준;강기웅;임세정
    • 한국전자통신학회논문지
    • /
    • 제2권1호
    • /
    • pp.10-18
    • /
    • 2007
  • 본 논문에서는 MTS(Multiple Time Scale) 트래픽 제어 프레임워크를 TCP(Transfer Control Protocol) 기반의 신뢰할 수 있는 전송 및 윈도우 기반 혼잡제어로 확대 적용한다. 이 작업은 TCP의 대역폭 소비 반응의 적극성을 LTS 네트워크 상태의 함수 형태, 즉 RTT(Round-Trip Delay Time)가 결정한 피드백 루프의 한계를 넘어서는 정보의 형태를 조정하는 LTS(Large Time Scale) 모듈과 TCP를 연계시키는 방법으로 수행된다. 혼잡 제어 성능 평가 방식은 자기 유사성 네트워크 트래픽의 물리적 모델링으로부터 얻은 시뮬레이션 기반 하에서 결과를 나타낸다. 자기 유사 버스트 환경 하에서 RTT가 450ms일 때 소스 트래픽이 초과되지 않는 경우에 TCP-SSC(Selective Slope Control)의 성능 이득은 각각 ${\alpha}$가 1.05일 45%정도 높아지는 반면에 ${\alpha}$가 1.95일 때는 20%정도의 성능 이득을 얻을 수 있다. 그러므로 비율 기반 피드백 혼잡 제어에 TCP-MTS를 적용함으로서 TCP-SCC 처리 이득의 성능이 약 2배정도의 개선이 이루어짐을 시뮬레이션 결과로부터 알 수 있다.

  • PDF

발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가 (Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities)

  • 이금호;이재호;이광호
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

절피원심법으로 대규모 채취한 누에체액의 곤충세포 증식효과 (Effect of Silkworm Hemolymph Collected Large-scale Bleeding Method in Insect Cell Culture)

  • 최지영;김종길;최영철;김삼은;한명세
    • 한국잠사곤충학회지
    • /
    • 제49권1호
    • /
    • pp.28-32
    • /
    • 2007
  • 누에체액이 동물세포 배양의 필수첨가물인 FBS를 대체할 수 있는 세포증식 효과가 있는 것으로 확인되었으나, 누에의 배발에 상처를 내어 채혈하는 방법으로는 대량 채취가 어렵다. 본 연구에서는 이러한 문제점을 해결코자 대량의 체액을 한꺼번에 얻을 수 있는 대규모 채혈법을 검토하게 되었다. 1. 누에 머리부분과 꼬리부분(배발 포함)에 상처를 낸 후 원심하여 체액을 채취하는 방법(절피원심법)이 기존의 소규모 채취한 체액과 유사한 세포증식 촉진효과를 보였다. 2. 절피원심한 체액의 원심속도에 따른 세포증식 촉진 효과는 500rpm과 1000rpm에서 양호한 값을 보였다. 3. 원심속도를 500rpm으로 고정한 경우 원심시간을 5분에서 30분까지 달리하여도 세포증식 효과는 유사하였고, 체액 회수율은 원심시간이 길어질수록 증가하였으나 일정시간 이상부터는 증가하지 않았다. 4. 절피원심법으로 대규모 채취한 체액의 액상회수율은 누에(백옥잠)생체중의 19.5%이었고, 분말회수율은 1.4% 이었으며, 분말체액에서도 세포증식 촉진 효과가 인정되었다.

굵은 입자가 포함된 풍화토의 전단강도 평가에 대한 실험연구 (An Experimental Study on the Evaluation of Shear Strength of Weathered Soil Containing Coarse Particles)

  • 김준석
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.169-176
    • /
    • 2024
  • 연구목적: 본 논문에서는 직접전단시험에서 시험시편의 규모 때문에 부득이 굵은 입자가 제외되는 문제 때문에 발생되는 전단강도의 차이를 분석하고자 직접전단시험을 실시하는 실험연구를 수행하였다. 연구방법: 최대직경 50mm의 굵은 골재가 포함된 3개의 풍화토를 대상으로 대형직접전단시험을 실시하였다. 또한 굵은 골재가 제외된 최대직경 5mm 시료를 이용하여 소형직접전단시험을 실시하였다. 연구결과: 소형직접전단시험의 경우 큰입자가 포함된 대형직접전단시험의 결과에 비하여 내부마찰각은 약2.3% 작은 값을 도출하여 비교적 큰 차이가 없었다. 점착력에서는 대형직접전단시험에 비하여 소형 직접전단시험이 약 80.3% 작은 값을 도출하여 비교적 큰 차이를 나타내었다. 결론: 대형직접전단시험에서 굵은 입자가 내부마찰각보다는 점착력에 큰 영향을 준 것으로 분석되었다. 따라서, 굵은 입자를 포함한 화강풍화토는 수직응력에 영향을 받지 않는 점착력과 같은 전단강도를 갖고 있는 것으로 판단된다. 본 연구에서는 일반적으로 사용되고 있는 굵은 입자를 제외한 소형직접전단시험은 굵은 입자의 효과를 제외함으로서 안전측의 결과를 제공하는 것으로 분석되었다.

Lrge-Scale 초음파 반응기에서의 내부 초음파 에너지 분포 분석 (Analysis of the Ultrasonic Cavitation Energy in a Large-Scale Sonoreactor)

  • 손영규;임명희;김원장;김지형
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.129-134
    • /
    • 2008
  • Ultrasonic cavitational energy distributions were measured in a large-scale sonoreator. In application of 110 and 170 kHz of ultrasound, the cavitational energy was just detected near the transducer module. However 35 and 72 kHz ultrasound made good distributions from the module to the end of the sonoreactor, Especially, 72 kHz ultrasound application showed most stable and highest cavitational energy value through the whole length. In the comparison between input power and cavitational energy, linear relationships were obtained in 35 and 72 kHz and it was anticipated that these results would be used for the optimization of input power for the design of sonoreactors. And three dimensional energy distribution was depicted through the mapping of cavitaional energy. Average energy in the large-scale sonoreactor was estimated as 62.8 W, which was about 40 % of input power.

대규모 절토사면의 효율적인 유지관리를 위한 연구 (A Study about efficient maintenance of large scale cut slope)

  • 박재영;신창건;정상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1051-1056
    • /
    • 2009
  • 절토사면 중 단일사면이 연장 200m, 높이 50m 이상일 경우 시설물 안전에 관한 특별법에 의거 2종 시설물로 지정되며 근래에 들어 광폭도로의 신설이 증가되어 2종 시설물에 속하는 절토사면의 개소수 또한 증가되는 상황이다. 대규모 절토사면의 경우 시공부터 유지관리까지 소규모에 비해 비교적 잘 이루어지는 상황이며, 보수 보강 공법 또한 잘 적용되어져 있다. 하지만 절취 면적이 넓고 대부분 식생 및 표면보호 등으로 인해 사면 내 육안조사가 용이하지 않다. 본 연구에서는 대규모 절토사면의 상태평가시 효율적인 평가 방안 및 평가결과에 따른 유지관리 방안을 논의하고자 한다.

  • PDF

대면적 고분자전해질연료전지의 병렬계산 시뮬레이션 (Parallel Computing Simulation of Large-Scale Polymer Electrolyte Fuel Cells)

  • 곽건희;푸루소타마;강경문;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.868-877
    • /
    • 2011
  • This paper presents a parallel computing methodology for polymer electrolyte fuel cells (PEFCs) and detailed simulation contours of a real-scale fuel cell. In this work, a three-dimensional two-phase PEFC model is applied to a large-scale 200 $cm^2$ fuel cell geometry that requires roughly 13.5 million grid points based on grid-independence study. For parallel computing, the large-scale computational domain is decomposed into 12 sub-domains and parallel simulations are carried out using 12 processors of 2.53 GHz Intel core i7 and 48GB RECC DDR3-1333. The work represents the first attempt to parallelize a two-phase PEFC code and illustrate two-phase contours in a representative industrial cell.

A STUDY ON THE PROCESS OF LARGE-SCALE REPAIR OF A CONDOMINIUM

  • Seki, Eiji;Akiyama, Tetukazu
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.295-300
    • /
    • 2002
  • Since the contents of large-scale repair of a condominium were various, a plan document was not prepared. The owners association of the condominium has given priority to decision-making of price priority over quality. Examination is not performed about the contents of the construction supervision business, which checks whether suitable construction is performed, either. On the other hand, the know-how for builders, such as decision of the process plan under which the repair work lessens influence to the safety and life as much as possible since the place where the resident is living turns into a construction site, and selection of a method of construction, is just going to ask. It is an important subject how the structure of the construction contractor selection, which considered quality, is built. Then, this research focuses on large-scale repair construction of the condominium, and arranges the actual condition of a series of processes from plan document creation to construction supervision. The method of research collects the construction documents of the condominium that carried out Barge-scale repair construction. Next, collection arrangement of the data of construction builder selection is carried out. The method of the construction builder selection of those other than a construction price is examined. The method of quality control of large-scale repair construction is examined.

  • PDF

대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전 (Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT))

  • 안종우;김건도;김기섭;박영하
    • 대한조선학회논문집
    • /
    • 제52권6호
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.