• 제목/요약/키워드: lap splices

검색결과 69건 처리시간 0.027초

저형상비 RC교각의 실물모형 준정적실험 (Quasi Static Test of Real Scaled RC Piers with Low-Aspect Ratio)

  • 조창백;곽임종;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.218-221
    • /
    • 2006
  • The past Korean Bridge Design Specifications have no limitation on the amount of lap splices of longitudinal bars in the plastic hinge zone of piers. A majority of bridge piers which have been non-seismically designed might have some lap splices in plastic hinge zone. Also a number of those piers in Korea have a low aspect ratio(height/section area). So, some problems such as low ductility behavior may happen. In this study, the real pier which was non-seismically designed and has a low aspect ratio was selected for the quasi-static tests. Two groups of full scaled RC pier models of which aspect ratios are about 2.26 and about 2.67 were fabricated. And then, quasi-static tests according to the drift level history method were implemented. From the test results, the failure of these test specimens have been shown in the complex shear-flexural or shear modes. The low aspect ratio and the lap splice have largely influenced on the seismic performance of bridge piers.

  • PDF

Steel Band로 보강된 철근콘크리트 교각의 내진성능 (Seismic Performance of RC Bridge Piers Retrofitted with Steel Bands)

  • 이대형;송희원;박창규;이범기;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.97-100
    • /
    • 2005
  • It has been known that lab splices of the longitudinal reinforcement steel in bridge columns are not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were usually be located in the plastic hinge region of most bridge columns that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification on 1992. This research is to evaluate the seismic performance of reinforced concrete bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, and to develop the enhancement scheme of their seismic capacity by retrofitting with steel bands. It was observed that RC bridge specimens with lap-spliced longitudinal steels appeared to fail at low curvature and displacement ductility, but significant improvement was appeared in the ductility of RC specimens with steel bands retrofitted around the plastic hinge region.

  • PDF

Comparison of code provisions on lap splices

  • Canbay, Erdem
    • Structural Engineering and Mechanics
    • /
    • 제27권1호
    • /
    • pp.63-75
    • /
    • 2007
  • The code provisions on lap splices are critically assessed in the light of 203 beams without transverse reinforcement and 278 beams with transverse reinforcement. For comparison, the provisions given in the ACI 318, Eurocode 2, and TS 500 Codes are considered. The ACI Committee 408 recommended provision and a new proposal are also taken into account throughout the assessment. The comparison with real beam tests where the splice region was subjected to constant moment indicates that current provisions in the Codes do not agree acceptably with test results. The steel stress prediction graphs calculated by means of the Code provisions show high scatter and remain unsafe especially for test data without transverse reinforcement. Both the recent recommended provision by ACI Committee 408 and a new design expression proposed by the author have much less scatter with fewer unsafe predictions. The simplified design provision proposed by ACI Committee 408 does not yield similar results to that of the advanced design provision proposed by the same committee and therefore it could conveniently be replaced with the simpler equation proposed by the author.

용융아연도금 철근콘크리트 보의 부착강도 특성 (Characteristics of Bond Strength in Concrete Beams Reinforced with Galvanized Rebar)

  • 신재혁;김경철;양인환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.136-143
    • /
    • 2015
  • 용융아연도금(galvanizing)은 콘크리트 구조물의 철근 부식 문제를 해결하기 위해 사용된다. 용융아연도금 철근 콘크리트 보의 부착강도 영향에 대한 자료는 거의 없는 실정이다. 따라서, 이 연구의 목적은 용융아연도금철근이 콘크리트 보의 부착강도에 미치는 영향을 파악하는데 있다. 용융아연도금철근을 사용한 부재와 일반철근을 사용한 부재의 구조실험을 통하여 겹침이음 거동과 부착강도 특성을 비교하였다. 실험변수로써 철근의 용융아연코팅 유무, 철근 직경과 겹침이음 길이를 고려하였다. 용융아연도금 철근콘크리트 보의 균열 및 파괴 특성을 파악하였다. 용융아연도금철근 콘크리트 보의 겹침이음부 휨 거동특성은 일반철근 콘크리트 보의 겹침이음부 휨거동과 유사한 것으로 나타난다. 또한, 용융아연도금철근의 사용은 일반철근을 사용할 때에 비해 콘크리트 보의 부착강도에 불리한 영향을 미치지는 않는 것으로 나타났다.

Seismic behaviour of RC columns with welded rebars or mechanical splices of reinforcement

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.;Konstantinidis, Dimitrios
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.297-306
    • /
    • 2019
  • The extension of existing RC buildings is a challenging process, which requires efficient connection between existing and new materials to guarantee load transferring between the lap-spliced longitudinal columns' reinforcement. Therefore, the length of the columns' starter bars is a crucial factor, which decisively affects the seismic response of the new columns. In particular, when the length of the starter bars is short, then the length of the lap splices of reinforcement is inadequate to ensure load transfer between steel bars and concrete, with an indisputable detrimental impact on the seismic behaviour of the columns. Moreover, in most of the existing RC buildings the column starter bars are of particularly short length, while they have probably been bent, cut or corroded. In the present study, the effectiveness of both welded rebar and mechanical splices of reinforcement in ensuring load transferring between the starter bars and the longitudinal reinforcement of the new column was experimentally evaluated. Four cantilever column subassemblages were constructed and subjected to earthquake-type loading. Three of the specimens were used to examine different types of shielded metal arc welding (SMAW), while in the fourth subassemblage mechanical splices were tested. The hysteretic response of the columns was evaluated and compared to the behaviour of a fifth specimen with continuous reinforcement, tested by Kalogeropoulos and Tsonos (2019). Test results clearly demonstrated that the examined types of SMAW were equally satisfactory in ensuring the ductile seismic performance of the columns, while the mechanical splices found to be more susceptible to exhibit slipping of the bars.

인장력을 받는 확대머리 이형철근의 겹침이음에 관한 실험적 연구 (Experimental Study on Lap Splice of Headed Deformed Reinforcing Bars in Tension)

  • 김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.59-67
    • /
    • 2014
  • 현행 콘크리트구조기준 (KCI2012) 및 ACI318-11에서 B급이음된 일자형 이형철근에 대하여 인장력에 대한 겹침이음길이를 정착길이의 1.3배로 산정하고 있다. 동일 기준에서 확대머리 이형철근의 정착길이를 제시하고 있지만 겹침이음상세에 대한 규정은 없다. 이에 본 연구에서는 400MPa과 500MPa 설계기준항복강도를 가지는 확대머리 이형철근의 겹침이음실험을 실시함으로써, 기준의 정착길이식을 겹침이음설계에 적용가능한 지를 평가하고자 하였다. 실험결과, SD400과 SD500의 설계기준항복강도를 적용한 확대머리 이형철근에 대하여 겹침이음길이를 정착길이의 1.3배로 산정할 경우, 실험 최대휨강도가 공칭휨강도에 비하여 16~31% 크게 평가되었고 연성적인 휨파괴 거동을 나타내었다. 따라서, 이들 철근에 대해 정착길이 1.3배의 겹침이음길이로 설계함으로써 강도 및 변형성능 측면에서 겹침이음 성능을 확보할 수 있는 것으로 사료된다.

겹침이음길이 및 구속 철근에 따른 헤드철근의 구조적 성능에 관한 실험적 연구 (An Experimental Study on the Structural Performance of Headed Bars by Lap Length and Confinement Details)

  • 유호일;이용택;김승훈;채서호;반병열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.286-289
    • /
    • 2006
  • Headed bars have used to the anchoring of the tension or compression longitudinal bars and of the shear reinforcing bars. Recently, lap splices of headed bars are attempted to the joints of precast concrete members and to the connections between old and new concrete members. Previous Michael's experimental research showed that confinement details had an effect on the lap splice performances of headed bars. In this study, the lap splice performances of headed bars(D25) with lap length and confinement details are evaluated through the experimental works. Four specimens, of which variables were the lap length of headed bar and the type of confine details, were tested for the performance evaluation on lap splice. Test results show that the lap length confinement reinforcement improve the performance of lap splice.

  • PDF

RC 기둥의 겹침이음파괴 시 철근의 응력 산정 (Calculation of Rebar Stress at Splice Failure of RC Columns)

  • 조재열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.446-449
    • /
    • 2006
  • Several experimental investigations have been carried out to study the behavior of reinforced concrete columns with short lap splices. However, very few analytical models have been developed for the analysis of such columns subjected to earthquakes. As nonlinear analysis procedures become more common in practice (such as those outlined in the Guidelines for Seismic Rehabilitation of Buildings published by the Federal Emergency Management Agency in the United States), the need for an accurate and reliable representation of the nonlinear response of strength degrading systems becomes more important. In this study, an analytical model for estimating the complete response of reinforced concrete columns with short lap splices is presented. The model is based on local bond stress-slip relationships and is validated against independent experimental data from cyclic loading tests on reinforced concrete columns with typical construction details of the 1960s. In this paper a simple equation for calculating the bar stress at splice failure is presented. Use of the proposed equation resulted in excellent agreement between the measured and calculated strength at splice failure.

  • PDF

횡보강근이 없는 100 MPa 이하 콘크리트의 철근 압축이음 강도와 이음길이 (Capacity and Length of Compression Lap Splice in Unconfined Concrete of 100MPa and Less Compressive Strength)

  • 천성철;이성호;오보환
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.659-666
    • /
    • 2010
  • 현행 설계기준식에 따르면 초고강도 콘크리트에서는 철근 인장이음길이보다 압축이음길이가 더 길어지는 현상이 발생된다. 압축이음은 단부 지압이 존재하므로, 인장이음보다 길 필요는 없다. 초고강도 콘크리트의 경제적 실용화를 위해 합리적인 압축이음강도의 평가가 필요하다. 이를 위해 설계강도 80, 100 MPa 콘크리트를 이용하여 횡보강근이 없는 압축이음 실험을 수행하였다. 실험 결과 압축이음강도는 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 지압에 의해 발현되는 이음강도는 이음길이와 무관하며 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 58개 실험체의 평균은 $16.5\;\sqrt{f_{ck}}$이다. 부착에 의해 발현되는 강도를 ACI 408식으로 평가한 결과 [실험값]/[이론값]의 비는 평균 0.94로, 인장이음의 부착강도와 거의 유사하였다. 따라서 인장이음강도에 대비한 압축이음강도의 향상은 단부 지압효과로 설명될 수 있다. 실험결과에서 분석된 이음길이와 콘크리트 강도의 영향 특성을 고려하여 압축이음강도 평가식과 압축이음길이 설계식을 제안하였다. 제안된 설계식은 통계적 기법에 기반을 두어, 이음부가 철근 재료강도와 동일한 수준의 신뢰성을 확보할 수 있다.

철근 압축이음에서 지압강도와 부착강도의 실험적 평가 (Experimental Evaluation of Bearing and Bond Strengths in Compression Splices)

  • 천성철;이성호
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.129-136
    • /
    • 2012
  • 철근 압축이음은 초고층 건축물의 수직 부재에서 거의 모든 층에서 발생되므로, 압축이음 거동에 대한 명확한 이해는 합리적인 이음부 설계에 필수 요소가 된다. 이 연구에서는 압축을 받는 철근이음의 인자별 특성을 분석하기 위해, 부착 또는 지압만 존재하는 압축이음 실험을 수행하였다. 실험 결과 부착과 지압이 함께 존재하는 일반이음에서는 부착과 지압의 상호 간섭으로 각각의 고유 강도가 100% 발현되지는 않았다. 특히 지압은 국부적인 영역에서 발현되므로 중첩으로 인한 감소량이 부착에 비해 컸다. 부착과 지압이 함께 존재하는 일반이음은 부착이음과 지압이음에 비해 동일하중에서 콘크리트와 철근의 상대변위를 줄일 수 있다. 이음 파괴는 콘크리트와 철근 사이의 과도한 상대변위로 인해 발생되므로 일반이음의 강도가 부착이음과 지압이음에 비해 항상 높아진다. 따라서 부착 또는 지압을 제거함으로써 압축이음강도를 향상시킬 수는 없다. 또한 부착이음에서 순수 부착강도는 인장이음의 부착강도와 거의 유사하게 나타났으므로, 압축이음강도가 인장이음강도보다 큰 것은 지압의 영향임을 알 수 있다.