DOI QR코드

DOI QR Code

Experimental Study on Lap Splice of Headed Deformed Reinforcing Bars in Tension

인장력을 받는 확대머리 이형철근의 겹침이음에 관한 실험적 연구

  • 김승훈 (한밭대학교 건축공학과)
  • Received : 2014.06.26
  • Accepted : 2014.07.21
  • Published : 2014.09.30

Abstract

In tension lap splices of straight deformed bars, KCI Code (KCI2012) and ACI Code (ACI318-11) requires that the lap lengths for class B splice are 1.3 times as development length. KCI2012 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. The purpose of this experimental study is to evaluate that KCI2012 equation for the development length, $l_{dt}$, of headed bars can be used to calculate the lap length, $l_s$, of headed deformed bars in grade SD400 and SD500, having specified yield strength of 400 and 500 MPa. Test results showed that specimens with $l_s$ equal to $1.3l_{dt}$ had maximum flexural strengths as 1.16~1.31 times as the nominal flexural strengths, flexural failure mode, and ductility. These observations indicate that $1.3l_{dt}$ is suitable to the tensile lap length of headed deformed bars in grade SD400 and SD500.

현행 콘크리트구조기준 (KCI2012) 및 ACI318-11에서 B급이음된 일자형 이형철근에 대하여 인장력에 대한 겹침이음길이를 정착길이의 1.3배로 산정하고 있다. 동일 기준에서 확대머리 이형철근의 정착길이를 제시하고 있지만 겹침이음상세에 대한 규정은 없다. 이에 본 연구에서는 400MPa과 500MPa 설계기준항복강도를 가지는 확대머리 이형철근의 겹침이음실험을 실시함으로써, 기준의 정착길이식을 겹침이음설계에 적용가능한 지를 평가하고자 하였다. 실험결과, SD400과 SD500의 설계기준항복강도를 적용한 확대머리 이형철근에 대하여 겹침이음길이를 정착길이의 1.3배로 산정할 경우, 실험 최대휨강도가 공칭휨강도에 비하여 16~31% 크게 평가되었고 연성적인 휨파괴 거동을 나타내었다. 따라서, 이들 철근에 대해 정착길이 1.3배의 겹침이음길이로 설계함으로써 강도 및 변형성능 측면에서 겹침이음 성능을 확보할 수 있는 것으로 사료된다.

Keywords

References

  1. ACI Committee 318 (2011), Building Code Requirements for Structural Concrete and Commentary, ACI 318-11.
  2. CEB No. 233 (1997), Design of Fastenings in Concrete, Stats of Art Report Design and Application, CEB.
  3. KCI 2012 (2012), Korean Concrete Structure Code, Korea Concrete Institute.
  4. Kim, S. H., Lee, Y. T., Kim, T. S., Chea, S. H. (2010), An Experimental Study on Noncontact Lap Splices of Headed Reinforcements with Different Effective Depths, Journal of Aik, 26(5), 3-10 (in Korean).
  5. Lee, Y. T., Kim, S. H., Chea, S. H., Bahn, B. Y. (2008), An Experimental Study on the Lap Strength of Headed Steel Reinforcements with Lap-spliced, Journal of Aik, 24(3), 87-94 (in Korean).
  6. Thompson, M. K., Ledesma, A., Jirsa, J. O., Breen, J. E. (2006), Lap Splices Anchored by Headed Bars, ACI Structural Journal, 103(2), 271-279.

Cited by

  1. Experimental Study on Effect of Confinement Details for Lap Splice of Headed Deformed Reinforcing Bars in Grade SD400 and SD500 vol.19, pp.1, 2015, https://doi.org/10.11112/jksmi.2015.19.1.062