• Title/Summary/Keyword: laboratory accident

Search Result 195, Processing Time 0.024 seconds

A Study on the statistiscal analysis and the Electrical Shock hazard for electrical power facilities of 22.9kV substation (22.9kV 수.변전설비의 감전사고 발생현황 및 감전위험성 연구)

  • Han, Ki-Boong;Lee, Dae-Jong;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1813-1815
    • /
    • 2002
  • As the statistical data, the electrical shock accidents by electrical power facilities of 22.9kV substation is about 100 per years which shows very high occupation rate of 11.3%. There is many hazard factors in this place using high voltage because electrical accident can be occurred in near live part as well as contact. Regarding electrical shock accident in 22.9kV substation as there are many cases that have not been exposed industrial disaster, it is very hard to know exact causes of such accidents in many cases, and therefore it is difficult to set up effective preventive measures. Therefore in this paper, it is intended to prepare the basic data to establish more effective preventive measures of electric shock accidents in 22.9kV substation through understanding the real conditions based on investigation and analysis in various types.

  • PDF

Parameter importance ranking for SBLOCA of CPR1000 with moment-independent sensitivity analysis

  • Xiong, Qingwen;Gou, Junli;Shan, Jianqiang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2821-2835
    • /
    • 2020
  • The phenomenon identification and ranking table (PIRT) is an important basis in the nuclear power plant (NPP) thermal-hydraulic analysis. This study focuses on the importance ranking of the input parameters when lacking the PIRT, and the target scenario is the small break loss of coolant accident (SBLOCA) in a pressurized water reactor (PWR) CPR1000. A total of 54 input parameters which might have influence on the figure of merit (FOM) were identified, and the sensitivity measure of each input on the FOM was calculated through an optimized moment-independent global sensitivity analysis method. The importance ranking orders of the parameters were transformed into the Savage scores, and the parameters were categorized based on the Savage scores. A parameter importance ranking table for the SBLOCA scenario of the CPR1000 reactor was obtained, and the influences of some important parameters at different break sizes and different accident stages were analyzed.

Radiation Measurements at Fukushima Medical University over a Period of 12 Years Following the Nuclear Power Plant Accident

  • Ryo Ozawa
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.153-161
    • /
    • 2023
  • Background: Fukushima Medical University (FMU) is located 57 km northwest of the Fukushima Daiichi Nuclear Power Plant. Our laboratory has been conducting environmental radiation measurements continuously before and after the nuclear accident. We aimed to report the observed behavior of radiation originating from the released radioactive materials due to the accident, predict future trends, and disseminate the results to the local residents. Materials and Methods: Measurements of the counting rate by a diameter of 76 mm and a length of 76 mm thallium-doped sodium iodide (NaI[Tl]) scintillation detector (S-1211-T; Teledyne Brown Engineering Environmental Services) in the central part of the laboratory, and the dose rate outward at the window by NaI(Tl) scintillation detector and digital processor (EMF211; EMF Japan Co. Ltd.) were conducted. Results and Discussion: Measurements by Teledyne S-1211-T showed that in the early stages, radiation from radioactive isotopes with short half-lives was dominant, while radiation from radioactive isotopes with longer half-lives became dominant as the measurement period became longer. Through nonlinear least squares regression, both short and long half-lives were successfully determined. It was also possible to predict how the radiation dose would decrease. The environmental radiation trends around FMU were measured by the EMF211. Both measurements were affected by rainfall and snow accumulation. Decontamination work on the FMU campus impacted measurements by the EMF211 especially. Conclusion: The results of two types of measurements, one at the center and the other at the window side of the laboratory, were presented. By applying a simplified model, radiation from radioactive isotopes with short and long half-lives was identified. Based on these results, future trends were predicted, and the information was used for public communication with the local residents.

Effect of Occupational Health and Safety Management System on Work-Related Accident Rate and Differences of Occupational Health and Safety Management System Awareness between Managers in South Korea's Construction Industry

  • Yoon, Seok J.;Lin, Hsing K.;Chen, Gang;Yi, Shinjea;Choi, Jeawook;Rui, Zhenhua
    • Safety and Health at Work
    • /
    • v.4 no.4
    • /
    • pp.201-209
    • /
    • 2013
  • Background: The study was conducted to investigate the current status of the occupational health and safety management system (OHSMS) in the construction industry and the effect of OHSMS on accident rates. Differences of awareness levels on safety issues among site general managers and occupational health and safety (OHS) managers are identified through surveys. Methods: The accident rates for the OHSMS-certified construction companies from 2006 to 2011, when the construction OHSMS became widely available, were analyzed to understand the effect of OHSMS on the work-related injury rates in the construction industry. The Korea Occupational Safety and Health Agency 18001 is the certification to these companies performing OHSMS in South Korea. The questionnaire was created to analyze the differences of OHSMS awareness between site general managers and OHS managers of construction companies. Results: The implementation of OHSMS among the top 100 construction companies in South Korea shows that the accident rate decreased by 67% and the fatal accident rate decreased by 10.3% during the period from 2006 to 2011. The survey in this study shows different OHSMS awareness levels between site general managers and OHS managers. The differences were motivation for developing OHSMS, external support needed for implementing OHSMS, problems and effectiveness of implementing OHSMS. Conclusion: Both work-related accident and fatal accident rates were found to be significantly reduced by implementing OHSMS in this study. The differences of OHSMS awareness between site general managers and OHS managers were identified through a survey. The effect of these differences on safety and other benefits warrants further research with proper data collection.

An Evaluation of Safety and Health Level in Chemical Laboratories

  • Lee, Keun-Won
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.33-37
    • /
    • 2007
  • In recent days, the accidents have happened at experimental laboratories in universities or institutes. In order to improve safety assurance of workers in laboratories, it is required to carry out systematic study concerned with evaluation of safety and health level. The safety and health inspection checklists were developed and conducted the case study. The case study was carried out laboratory safety inspection with 5 inspectors by the checklists to become aware of safety and health level. From the evaluation results of the inspection, we could be made quantification of laboratory through evaluation of safety and health level in laboratory. It was found that was recognized present states of the laboratory and established a plan for improvements in laboratory safety facilities from the case study. The safety inspection checklists can be used as basic data to establish evaluation criteria of safety and health level.

Study on Developing Emergency Response Procedure in Laboratory accident with Wireless Detecting System (무선 감시 시스템을 활용한 연구실 사고의 비상대응체계 개발에 대한 연구)

  • Lee, Man Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.139-145
    • /
    • 2015
  • In these days, hazards in laboratories are consistently increasing due to high technological advance in modern science. Efforts to prevent accidents in laboratories became law named [ACT ON THE ESTABLISHMENT OF SAFE LABORATORY ENVIRONMENT]. The law made laboratories more safely but it's not enough to keep up laboratory safety in advanced countries. To improve laboratory safety, this study reformed laboratory emergency response flow chart based on each emergency scenarios and its evaluated hazards in laboratories applied wireless hazard detecting equipments.

Flow blockage analysis for fuel assembly in a lead-based fast reactor

  • Wang, Chenglong;Wu, Di;Gui, Minyang;Cai, Rong;Zhu, Dahuan;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3217-3228
    • /
    • 2021
  • Flow blockage of the fuel assembly in the lead-based fast reactor (LFR) may produce critical local spots, which will result in cladding failure and threaten reactor safety. In this study, the flow blockage characteristics were analyzed with the sub-channel analysis method, and the circumferentially-varied method was employed for considering the non-uniform distribution of circumferential temperature. The developed sub-channel analysis code SACOS-PB was validated by a heat transfer experiment in a blocked 19-rod bundle cooled by lead-bismuth eutectic. The deviations between the predicted coolant temperature and experimental values are within ±5%, including small and large flow blockage scenarios. And the temperature distributions of the fuel rod could be better simulated by the circumferentially-varied method for the small blockage scenario. Based on the validated code, the analysis of blockage characteristics was conducted. It could be seen from the temperature and flow distributions that a large blockage accident is more destructive compared with a small one. The sensitivity analysis shows that the closer the blockage location is to the exit, the more dangerous the accident is. Similarly, a larger blockage length will lead to a more serious case. And a higher exit temperature will be generated resulting from a higher peak coolant temperature of the blocked region. This work could provide a reference for the future design and development of the LFR.

Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA (ETA를 통한 연구실험실 콘센트회로의 전기재해 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

A Study on the Priority Evaluation of Prevention Factors and Strategies to Minimize Industrial Accident Cause (산재원인을 최소화하기 위한 예방인자 및 전략의 우선순위 평가에 관한 연구)

  • Kang, Young-Sig;Choi, Man-Jin;Yang, Sung-Hwan;Yoon, Yong-Gu;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.1-9
    • /
    • 2008
  • It is very important to evaluate the priority of prevention factors and strategies in order to minimize industrial accident. It provides decisive information for accident prevention and safety management. Therefore, this paper proposes evaluation method of the priority through statistic testing with prevention factors and strategies by the cause analysis of cause and effect models. Especially, this paper uses priority matrix criterion to justify application of rank and objectivity. This paper is based on the results of a questionnaire of workers and managers who are engaged by real manufacturing and construction industries with less than 300 workers in the central region of Korea, where most of the fatal accidents have happened. Finally, the result provides one way to implement safety management for industrial accident prevention.

Modified Zhu Ling Tang Administration for Asymptomatic Microhematuria Due to Suspicion of Kidney Trauma Following a Motor Vehicle Accident: a Case Report (교통사고 이후 신장외상 의심소견에 의한 무증상성 미세혈뇨의 저령탕 가감 투여 경과 : 증례보고)

  • Kim, Bo-min;Jo, Hee-geun
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.551-556
    • /
    • 2019
  • Objectives: This study aimed to introduce a clinical case of asymptomatic microhematuria due to suspicion of kidney trauma following a motor vehicle accident. Methods: A 19-year-old male was hospitalized with the chief complaint of back pain after a motor vehicle accident. He showed an elevated urine red blood cell (RBC) level in the laboratory test, although no specific traumatic lesions were present on the body. He was assessed to have asymptomatic microhematuria, and Zhu Ling Tang (polyporus decoction) was given to him to be taken three times daily. Results: After the treatment, the level of urine red blood cells returned to normal range. Adverse events were not observed. Conclusions: Zhu Ling Tang caused a short-term improvement in the urinalysis levels of a patient with asymptomatic hematuria. However, further studies are needed, as this study is only a single-case report.