• Title/Summary/Keyword: joint test

Search Result 3,290, Processing Time 0.034 seconds

A Study on the HEVC Video Encoder PMR Block Design (HEVC 비디오 인코더 PMR 블록 설계에 대한 연구)

  • Lee, Sukho;Lee, Jehyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.141-146
    • /
    • 2016
  • HEVC/H.265 is the latest joint video coding standard proposed by ITU-T SG 16 WP and ISO/IEC JTC 1/SC29/WG 11. In H.265, pictures are divided into a sequence of coding tree units(CTUs), and the CTU further is partitioned into multiple CUs to adapt to various local characteristics. Its coding efficiency is approximately two times high compared to previous standard H.264/AVC. However according to the size of extended CU(coding unit) and transform block, the hardware size of PMR(prediction/mode decision/reconstruction) block within video encoder is about 4 times larger than previous standard. In this study, we propose a new less complex hardware architecture of PMR block which has the most high complexity within encoder without any noticeable PSNR loss. Using this simplified block, we can shrink the overall size the H.265 encoder. For FHD image, it operates at clocking frequency of 300 MHz and frame rate of 60 fps. And also for the test image, the Bjøntegaard Delta (BD) bit rate increase about average 30 % in PMR prediction block, and the total estimated gate count of PMR block is around 1.8 M.

MECHANICAL PROPERTIES OF LASER-WELDED CAST TITANIUM AND TITANIUM ALLOY (원심 주조된 타이타늄과 타이타늄 합금의 레이저 용접 특성)

  • Yun, Mi-Kyung;Kim, Hyun-Seung;Yang, Hong-So;Vang, Mong-Sook;Park, Sang-Won;Park, Ha-Ok;Lee, Kwang-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.642-653
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the effect of the output energy(voltage) of laser welding on the strength and properties of joint of cast titanium(CP Gr II) and titanium alloy(Ti-6Al-4V). Material and method : Cast titanium and its alloy rods(ISO6871) were prepared and perpendicularly cut at the center of the rod. After the cut halves were fixed in a jig, and the joints welded with a laser-welding machine at several levels of output voltage of $200V{\sim}280V$. Uncut specimens served as the non-welded control specimens The pulse duration and pulse spot size employed in this study were 10ms and 1.0mm respectively. Tensile testing was conducted at a crosshead speed of 0.5mm/min. The ultimate tensile strength(MPa) was recorded, and the data (n=6) were statistically analyzed by one-way analysis of variance(ANOVA) and Scheffe's test at ${\alpha}$=0.05. The fracture surface of specimens investigated by scanning electron microscope (SEM). Vickers microhardness was measured under 500g load of 15seconds with the optimal condition of output voltage 280V. Results : The results of this study were obtained as follows, 1. When the pulse duration and spot size were fixed at 10ms and 1.0mm respectively, increasing the output energy(voltage) increased UTS values and penetration depth of laser welded to titanium and titanium alloy. 2. For the commercial titanium grade II, ultimate tensile strength(665.3MPa) of the specimens laser-welded at voltage of 280V were not statistically(p>0.05) different from the non-welded control specimens (680.2MPa). 3. For the titanium alloy(Ti-6Al-4V), ultimate tensile strength(988.3MPa) of the specimens laser-welded at voltage of 280V were statistically(p<0.05) different from the non-welded control specimens (665.0MPa). 4. The commercial titanium grade II and titanium alloy(Ti-6Al-4V) were Vickers microhardness values were increased in the fusion zone and there were no significant differences in base metal, heat-affected zone.

An Experimental Study on the Failure of a Novel Composite Sandwich Structure (새로운 형상의 복합재 샌드위치 체결부 구조의 파손거동 연구)

  • Kwak, Byeong-Su;Kim, Hong-Il;Dong, Seung-Jin;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • The failure of composite sandwich structures with thickness and material variation was studied. The main body of the structure is sandwich plate made of the carbon composite face and Aluminum honeycomb core. It is connected with composite laminated flange without core through transition region of tapered sandwich panel with foam core. Tension and compression tests were conducted for the total of 6 panels, 3 for each. Test results showed that the panels under compression are vulnerable to the face failure along the material discontinuity line between two different cores. However the failure load of which panel does not show such failure can carry 16% more load and fails in honeycomb core and face debonding. For the tensile load, the extensive delamination failure was observed at the corner radius which connects the panel and the flange. The average failure load for compression is about 7 times the tensile failure load. Accordingly, these sandwich structures should be applied to the components that endure the compressive loadings.

Effect of Paddy-upland Rotation System on Soil Chemical Properties and Rice Yield (답전윤환형태별(畓田輪換形態別) 토양화학성(土壤化學性)과 수도생산성(水稻生産性) 변화(變化)에 관(關)한 연구(硏究))

  • Ahn, Sang-Bae;Motomatsu, T.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.3
    • /
    • pp.181-188
    • /
    • 1993
  • The effects of paddy-upland rotation and cropping system on the mineralization of soil organic nitrigen, on the change of organic matter and available phosphorus content in the soil, and on the rice yield and nutrients absorption were studied in Seokcheon fine-sandy loam soil. 1. In the incubation test mineralzed soil nitrogen and the nitrogen extracted by pH 7 phosphate buffer solutions were higher in the soils from every and two year rotation systems than continuous rice cultivation. In terms of cropping system potato-chiness cabbage-rice increased them more than soybean-rice system. 2. The change of soil organic matter and available phosphorus contents were not much in continuous rice cultivation, while in rotation system they decreased as the paddy-upland rotation frequency decreased. In terms of cropping system they decresed more in potato-Chinese cabbage-rice system compared with soybean-rice systems. 3. The rice yield was higher in the paddy-upland rotation system than that of continuous rice cultivation. However, the effects were decreased gradually every year, as shown by 26~20, 17~5, and 5~4% yield increase for first, second, and third year, respectively, in potato-Chinese cabbage-rice and soybean-rice system compared with continuous rice cultivation. 4. All the absorbed nutrient contents increased in every and two year rotation system compared with continuous rice cultivation. In terms of cropping system potato-Chiness cabbage-rice system increased them more compared with soybean-rice system.

  • PDF

Effect of Hip External Rotation Angle on Pelvis and Lower Limb Muscle Activity During Prone Hip Extension (엎드린 자세에서 고관절 신전 시 고관절 외회전 각도가 골반과 하지 근활성도에 미치는 영향)

  • Oh, Yun-Chan;Cynn, Heon-Seock;Yi, Chung-Hwi;Jeon, Hye-Seon;Yoon, Tae-Lim
    • Physical Therapy Korea
    • /
    • v.21 no.3
    • /
    • pp.1-10
    • /
    • 2014
  • The aim of this study was to investigate the effect of hip external rotation angle on pelvis and lower limb muscle activity during prone hip extension. Sixteen healthy men were recruited for this study. Each subject performed an abdominal drawing-in maneuver (ADIM) in a prone position, and extended the dominant hip at three different hip external rotation angles ($0^{\circ}$, $20^{\circ}$, $40^{\circ}$) with a $30^{\circ}$ hip joint abduction. Activity of the gluteus maximus (G Max), gluteus medius (G Med), and hamstring (HAM) and the G Max/HAM and G Med/HAM ratios were determined with surface electromyography (EMG). The EMG signal was normalized to 100% maximum voluntary isometric contractions (MVICs) and expressed as %MVIC. Data were analyzed by one-way repeated analysis of variance (alpha level=.05) and the Bonferroni post hoc test. Significant differences in G Max and G Med muscle activity were noted among the three different hip external rotation angles. G Max muscle activity increased significantly at both $40^{\circ}$ (p=.006) and $20^{\circ}$ (p=.010) compared to a $0^{\circ}$ hip external rotation angle. G Med muscle activity increased significantly at $20^{\circ}$ (p=.013) compared to a $40^{\circ}$ hip external rotation angle. The G Max/HAM activity ratio increased significantly at both $40^{\circ}$ (p=.004) and $20^{\circ}$ (p=.014) compared to a $0^{\circ}$ hip external rotation angle. The G Med/HAM activity ratio increased significantly at $20^{\circ}$ (p=.013) compared to a $40^{\circ}$ hip external rotation angle. In conclusion, $40^{\circ}$ and $20^{\circ}$ hip external rotation angles are recommended to increase G Max activity, and $20^{\circ}$ hip external rotation is advocated to enhance G Med muscle activity during prone hip extension with ADIM and $30^{\circ}$ hip abduction in healthy subjects.

Diagnostic Efficacy of PET in Soft Tissue Tumors: Comparative Study with Conventional Methods (연부 조직 종양에서 PET의 유용성: 기존의 진단법과의 비교 연구)

  • Seo, Sung-Wook;Park, Sang-Min;Cho, Hwan-Seong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.32-39
    • /
    • 2005
  • Introduction: Currently, F-18 fluorodeoxyglucose positron emission tomography scans (FDG-PET) has been investigated in soft tissue tumor especially for tumor detection and noninvasive grading. However, the validity and the efficacy of FDG-PET are still unclear in clinical evaluation. The purpose of this study is to determine the efficacy of FDG-PET in compared to conventional diagnostic imaging studies currently used in the soft tissue tumor. Methods: Between March 2001 and March 2002, 29 patients (sixteen males, thirteen females, mean age, 47 years; a range from 4 to 73) diagnosed with soft tissue tumor were evaluated by both conventional diagnostic imaging and FDG-PET. Valid reference test of the local lesion was the histopathologic diagnosis, which was measured in all patients. The suspecting metastasis in the imaging studies was validated by pathology or follow up imaging for at least 6 months. Each imaging diagnosis was made independently. The accuracy of each diagnostic method was evaluated. The incremental cost accuracy ratio was determined in each diagnostic method. Results: For detection of local lesion, sensitivity, specificity, and accuracy for MRI and FDGPET scans were 91%, 57%, 83% and 95%, 43%, 83% respectively. For detection of distant lesion, sensitivity, specificity, accuracy for conventional diagnostic methods and FDG-PET scans were 77%, 89%, 87% and 92%, 94%, 93% respectively. The incremental cost accuracy ratio (ICAR) of FDG-PET for detection of distant lesion was 145,000won/%. According to ICAR for each tumor grade, PET strategy is most cost-effective at high grade tumors. Conclusions: For detection of local lesion such as recurrence or remnant tumor, FDG-PET scan was not more accurate than MRI. However, It was more accurate for detection of metastatic lesion than conventional methods. For detection of high grade tumor, PET was most costeffective than for detection of lower grade tumor.

  • PDF

Evaluation on Structural Performance of Joint with Asymmetric Ribbed Connection Details used in Precast Bridge Deck (비대칭 격벽단면을 갖는 프리캐스트 바닥판 이음부의 구조성능 평가)

  • Chung, Chul-Hun;Byun, Tae-Kwan;Kim, In-Gyu;Shin, Dong-Ho;Lee, Han-Joo
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.159-167
    • /
    • 2017
  • A precast concrete deck system is considered an effective alternative in terms of its rapid construction and quality assurance than cast-in-place concrete deck. In precast concrete deck system, structural performance and serviceability are mostly determined by the connection methods between the precast decks. This research proposes more improved precast deck system with asymmetric ribbed connection details improving the disadvantage of previous precast deck system such as difficulties in assembling precast decks. And in this precast deck system, a separate form is not required at the site because partition wall of the precast decks serves as a form when placing non-shrinkage mortar in the connection part of the precast decks. Therefore, rapid construction is possible. Flexural performance is verified through load tests considering main parameter such as rib length in the precast deck connection. From the test results, it can be inferred that the development of the rebar and prevention of adhesion failure in the partition wall of the precast deck system are important factors in securing the flexural performance. Although the structural performance of the precast deck system with asymmetric connection details is gradually reduced as the rib length in the precast deck connection increases, the proposed precast deck system shows sufficient flexural performance and can be applied to the connection part of precast decks effectively.

A Study on Comparison of Massive Data Recording Equipments for VLBI Radio Observation Data (VLBI 전파 관측데이터를 위한 대용량 기록장치 비교에 관한 연구)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • KVN(Korean VLBI Network) introduced the Mark6 system of the MIT haystack observatory as a recorder for data recording up to 32 Gbps for VLBI(Very Long Baseline Interferometry) observation. The Mark6 recorder can record data at up to 32Gbps when two systems and 64 HDDs are installed. However, because of the unique recording method that is characteristic of Mark6, we are introducing a large amount of data into a virtual file system, or using a general RAID method, which causes data loss when reading and transferring files at the highest recording speed or file system have. The Flexbuff system, a software recorder developed by JIVE(Joint Institute for VLBI ERIC), can be configured to operate as a data recorder through RAID configuration and network upgrades. In particular, when installed in the Mark6 system, it can record VLBI data at a maximum speed of 32 Gbps with less loss of data compared to the existing Mark6 by utilizing Mark6 resources well. In this paper, we propose that the existing Mark6 system can be operated as Mark6-Flexbuff by installing jive5ab software, and it is verified through experiment that it can be effectively used for VLBI observation operation through data recording test.

THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR (구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향)

  • Lee, Kang;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

The Correlation between Korean Medical Treatment on Knee Joint Pain and BMI (슬관절 통증 환자의 한의학적 치료 호전도와 BMI 와의 상관성)

  • Kim, Sang-Min;Lee, Sun-Ho;Choi, Ji-Hoon;Kim, Hyun-Joong;Koo, Ja-Sung;Jang, Jae Won;Lee, Dong-hyun;Yoo, Hyung Jin
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.11 no.1
    • /
    • pp.65-74
    • /
    • 2016
  • Objectives : This study was designed to assess the general distribution, clinical effectiveness of Korean medical treatment on knee pain and the correlation between Korean medical therapy on knee pain and BMI. Methods : This is an observational study. 65 patients admitted to Daejeon Jaseng Hospital of Korean Medicine with musculoskeletal disorders were observed from July, 2014 to July, 2015. They were analyzed according to sex, age, pain lesion, body mass index(BMI) and treatment efficacy. All patients received a combination of treatments during hospitalization, including acupuncture, pharmacopuncture, herbal medicines and physical therapy. A zero to ten numerating rating scale (NRS) assessing pain, Western Ontario and McMaster Universities Arthritis Index(WOMAC) index and Range of Motion(ROM) was used before and after treatments. Statistical correlations among assessment measurements were evaluated by examining the paired t-test and the Pearson's correlation coefficients. Results : The average BMI of all patients was $24.03{\pm}2.95kg/m^2$. According to clinical definition of obesity by Korean Society for the Study of Obesity, 33.8% of all patients was within normal weight, 1.5% was underweight, 33.8% was overweight, 24.6% was obesity and 6.2% was morbid obesity. For knee pain patients, NRS (Numeric Rating Scale) decreased from $6.28{\pm}1.63$ to $3.94{\pm}2.03$(p<0.001). WOMAC index decreased from $48.14{\pm}17.63$ to $40.37{\pm}18.28$(p<0.001). But, there were no significant correlations in statistics among BMI, knee pain index and knee pain index improvement. Conclusions : Korean medical combination treatment might be effective in reducing pain and improving functional disorders for patients with knee pain. This study further confirmed the efficacy of Korean medical treatment on knee pain. But, more studies on correlation between knee pain and obesity and development of assessment measurement are needed.

  • PDF