• Title/Summary/Keyword: jitter

Search Result 914, Processing Time 0.034 seconds

Comparative Study on Jitter Control Methods for Improving Real-Time Control Performance (실시간 제어 성능 향상을 위한 지터 제어 기법의 비교 연구)

  • Park, Moon-Ju;Lim, Yang-Mi
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • This paper compares and studies scheduling methods to reduce jitter in real-time control systems. While previous research has focused on dynamic-priority scheduling schemes, this paper focuses on fixed-priority scheduling which is more widely used. It is pointed out that previously defined jitter measures might not be useful in enhancing the control performance of a real-time task because the measures are relative values. We present a new jitter measure and a new scheduling scheme for fixed-priority tasks. The experimental results through simulation show that the new scheduling scheme reduces jitter and enhances control performance.

The Effectiveness of Electroglottographic Parameters in Differential Diagnosis of Laryngeal Cancer (후두암 감별진단에 있어 성문전도(Electroglottograph) 파라미터의 유용성)

  • 송인무;고의경;전경명;권순복;김기련;전계록;김광년;정동근;조철우
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.1
    • /
    • pp.16-25
    • /
    • 2003
  • Background and Objectives : Electroglottography(EGG) is a non-invasive method of monitoring the vocal cord vibration by measuring the variation of physiological impedance across the vocal folds through the neck skin. It reveals especially the vocal fold contact area and is widely used for basic laryngeal researches, voice analysis and synthesis. The purpose of this study is to investigate the effectiveness of EGG parameters in differential diagnosis of laryngeal cancer. Materials and Methods : The author investigated 10 laryngeal cancer and 25 benign laryngeal disease patients who visited at the Department of Otolaryngology, Pusan National University Hospital. The EGG equipment was devised in the author's Department. Among various parameters of EGG, closed quotient(CQ), speed quotient(SQ), speed index(SI), Jitter, Shimmer, Fo were determined by an analysis program made with MATLAB 6.5$^{\circledR}$(Mathwork, Inc.). In order to differentiate various laryngeal diseases from pathologic voice signals, the author has used the electroglottographic parameters using the neural network of multilayer perceptron structure. Results : SQ, SI, Jitter and Shimmer values except those of CQ and Fo showed remarkable differences between benign and malignant laryngeal disease groups. From the artificial neural network, the percentage of differentiating the laryngeal cancer was over 80% in SQ, SI, Jitter, Shimmer except for CQ and Fo. These results indicated that it is possible to discriminate the benign and malignant laryngeal diseases by EGG parameters using the artificial neural network. Conclusion : If parameters of EGG which can reveal for the pathology of laryngeal diseases are additionally developed and the current classification algorithm is improved, the discrimination of laryngeal cancer will become much more accurate.

  • PDF

Acoustic Analysis of Normal and Vocal Pathologic Voice Using Dr. Speech Science (Dr. Speech Science를 이용한 정상 및 후두질환 환자의 음향분석)

  • Lee, Hyung-Seok;Tae, Kyung;Jang, Kyung-Jin;Kim, Kyung-Woo;Kim, Kyung-Rae;Park, Chul-Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.2
    • /
    • pp.166-172
    • /
    • 1997
  • Background : For example, aerodynamic study, vibratory study, acoustic study, neuro-muscular test and psychoacoustic evaluation, a number of objective methods are now available for assessing pathologic voice change. They help to differentiate pathologic condition from normal condition and to monitor pathologic and aging change. These laboratory analyses are used commonly to monitor speech therapy and to follow a patient's recovery after surgery. Objectives : We investigated the values of jitter, shimmer and NNE of normal person and hoarseness patients in Korea. The values of Jitter and shimmer might be meaningful parameters distinguishing pathologic vibration from normal and recovery after surgery. Materials and Methods : Statistical significance between normal control and 48 subjects taken microlaryngeal surgery were compared with Dr. speech science program that is computerized system for acoustic analysis of voice production employed to determine vocal characteristics of pitch perturbation(jitter) and amplitude perturbation(shimmer). Results : The mean normal values of jitter and shimmer were 0.226${\pm}$0.110(%), 2.200${\pm}$0.421(%) in male and 0.164${\pm}$0.060(%), 2.063 ${\pm}$0.575(%) in female. In patients with vocal nodule, the preoperative and postoperative values of jitter and shimmer were valueless. In patients with vocal polyps, the preoperative and postoperative values of jitter and shimmer were valuable. Conclusion : Dr. speech science program was effective to monitor laryngeal disease and aging changes.

  • PDF

Analysis and synthesis of pseudo-periodicity on voice using source model approach (음성의 준주기적 현상 분석 및 구현에 관한 연구)

  • Jo, Cheolwoo
    • Phonetics and Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.89-95
    • /
    • 2016
  • The purpose of this work is to analyze and synthesize the pseudo-periodicity of voice using a source model. A speech signal has periodic characteristics; however, it is not completely periodic. While periodicity contributes significantly to the production of prosody, emotional status, etc., pseudo-periodicity contributes to the distinctions between normal and abnormal status, the naturalness of normal speech, etc. Measurement of pseudo-periodicity is typically performed through parameters such as jitter and shimmer. For studying the pseudo-periodic nature of voice in a controlled environment, through collected natural voice, we can only observe the distributions of the parameters, which are limited by the size of collected data. If we can generate voice samples in a controlled manner, experiments that are more diverse can be conducted. In this study, the probability distributions of vowel pitch variation are obtained from the speech signal. Based on the probability distribution of vocal folds, pulses with a designated jitter value are synthesized. Then, the target and re-analyzed jitter values are compared to check the validity of the method. It was found that the jitter synthesis method is useful for normal voice synthesis.

An Analysis of Service Quality affected by Allowing Maximum Delay Jitter (최대 지연지터의 허용이 서비스 품질에 미치는 영향에 대한 분석)

  • Lee, Keun-Wang
    • Journal of KIISE:Information Networking
    • /
    • v.27 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • It is important interest for us to solve skew problem in intermedia synchronization and to solve jitter problem in intramedia synchronization. It propose multimedia synchronization model to represent mixed media which contain temporal media and spatial media, and that helps us to develop multimedia application software efficiently. The proposed paper use four parameters to deal with QoS of intermedia synchronization and relative duration time algorithm and jitter-compensatory time algorithm are presented. When key medium is destroyed we make a delay as much as maximum delay jitter of the key medium in order to playout the other medium as much as that. The result is that the application of maximum delay jitter improves the service quality.

  • PDF

Design of low jitter CDR using a single edge binary phase detector (단일 에지 이진위상검출기를 사용한 저 지터 클록 데이터 복원 회로 설계)

  • An, Taek-Joon;Kong, In-Seok;Im, Sang-Soon;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.544-549
    • /
    • 2013
  • This paper describes a modified binary phase detector (Bang-Bang phase detector - BBPD) for jitter reduction in clock and data recovery (CDR) circuits. The proposed PD reduces ripples in the VCO control voltage resulting in reduced jitter for CDR circuits. A 2.5 Gbps CDR circuit with a proposed BBPD has been designed and verified using Dongbu $0.13{\mu}m$ CMOS technology. Simulation shows the CDR with proposed PD recovers data with peak-to-peak jitter of 10.96ps, rms jitter of 0.86ps, and consumes 16.9mW.

A Clock Generator with Jitter Suppressed Delay Locked Loop (낮은 지터를 갖는 지연고정루프를 이용한 클럭 발생기)

  • Nam, Jeong-Hoon;Choi, Young-Shig
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.17-22
    • /
    • 2012
  • A novel Clock Generator with jitter suppressed delay-locked loop (DLL) has been proposed to generate highly accurate output signals. The proposed Clock Generator has a VCDL which can suppress its jitter by generating control signals proportional to phase differences among delay stages. It has been designed to generate 1GHz output at 100MHz input with 1.8V $0.18{\mu}m$ CMOS process. The simulation result demonstrates a 3.24ps of peak-to-peak jitter.

Jitter Tolerances in Digital Transmission Equipment (디지틀 전송 장치의 지터 허용치)

  • Ko, Jeong-Hoon;Lee, Man-Seop;Park, Moon-Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.14-21
    • /
    • 1989
  • In the digital transmission equipment, the input jitter tolerance is a function of input timing recovery circuit characteristics. Especially, in the asynchronous multiplexers, it is also a function of the frame format, the buffer sizes in the synchronizer and desynchronizer, the PLL transfer function, and operating range of VCO in PLL In this paper, a new algorithm for calculating the jitter tolerance of the saynchronous digital transmission equipment is presented. With the new algorithm, we analyzed how the above factors limit the jitter tolerance in the equipment. We also measured the input jitter tolerance for a 45M-140M multiplexing equipment, whose results show the same trend with calculated tolerance.

  • PDF

Calculation of UWB Communication System Capacity with Timing litter (타이밍 지터를 고려한 UWB 통신 시스템 용량 계산)

  • 박장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.767-773
    • /
    • 2004
  • An UWB communication system are a promising communication technique suitable for the current trends, which are requesting communication methods with the high throughputs and very high speed. A key feature of UWB communication systems is the very narrow pulse used in transmitting the data and PPM(Pulse Position Modulation) for modulating the data. So, the timing accuracy is very important. It is very important to accurately analyze the effect of the timing jitter on the performance of UWB communication systems. In this paper, the methods of analyzing the timing jitter effects on UWB communication systems are introduced. In particular, the channel capacities with timing jitter are calculated including the multiuser access interference.