• Title/Summary/Keyword: jig

Search Result 683, Processing Time 0.029 seconds

Experimental and Numerical Study of Berthing and Unberthing of LNG-Bunkering Vessels (실험 및 수치해석을 통한 LNG 벙커링 선박들의 이접안 안정성 평가 연구)

  • Jung, Sung-Jun;Oh, Seung-Hoon;Jung, Dong-Woo;Kim, Yun-Ho;Jung, Dong-Ho
    • Journal of Navigation and Port Research
    • /
    • v.44 no.6
    • /
    • pp.439-446
    • /
    • 2020
  • The IMO has adopted emission standards through Annex VI of the International Convention for the Prevention of Pollution from Ships (MARPOL) that strictly prohibit the use of bunker C oil for vessels. In this study, we have adopted the turret-moored Floating LNG-Bunkering Terminal (FLBT) which is designed to receive the LNG from LNGCs and transfer it to LNG-bunkering shuttles in side-by-side moored condition. Numerical analyses were carried out using the high-order boundary-element method for four vessels at various relative distances. Mean wave drift forces were compared in an operational sea state. A model test was performed in the ocean engineering basin at the Korea Research Institute of Ships & Ocean Engineering (KRISO) to verify the safety of the berthing/unberthing operation. In the model test, a jig was designed to simulate tug boats pushing or pulling the bunkering vessels, so that the friction force of the g operation was not affected. Safety depended on the environmental direction, with more stable operation possible if the heading-control function of FLBT is applied to avoid beam-sea conditions.

Design and Implementation of a Data-Driven Defect and Linearity Assessment Monitoring System for Electric Power Steering (전동식 파워 스티어링을 위한 데이터 기반 결함 및 선형성 평가 모니터링 시스템의 설계 구현)

  • Lawal Alabe Wale;Kimleang Kea;Youngsun Han;Tea-Kyung Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.2
    • /
    • pp.61-69
    • /
    • 2023
  • In recent years, due to heightened environmental awareness, Electric Power Steering (EPS) has been increasingly adopted as the steering control unit in manufactured vehicles. This has had numerous benefits, such as improved steering power, elimination of hydraulic hose leaks and reduced fuel consumption. However, for EPS systems to respond to actions, sensors must be employed; this means that the consistency of the sensor's linear variation is integral to the stability of the steering response. To ensure quality control, a reliable method for detecting defects and assessing linearity is required to assess the sensitivity of the EPS sensor to changes in the internal design characters. This paper proposes a data-driven defect and linearity assessment monitoring system, which can be used to analyze EPS component defects and linearity based on vehicle speed interval division. The approach is validated experimentally using data collected from an EPS test jig and is further enhanced by the inclusion of a Graphical User Interface (GUI). Based on the design, the developed system effectively performs defect detection with an accuracy of 0.99 percent and obtains a linearity assessment score at varying vehicle speeds.

Scarf Welding of Thin Substrates and Evaluation of the Tensile Properties (박형 기판의 사면 접합 공정 및 인장 특성 평가)

  • Beomseok Kang;Jeehoo Na;Myeong-Jun Ko;Minjeong Sohn;Yong-Ho Ko;Tae-Ik Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.102-110
    • /
    • 2023
  • This paper introduces scarf welding process of thin substrates using flexible laser transmission welding (f-LTW) technology. We examined the behavior of tensile strength relative to the scarf angle for flexible applications. Thin plastic substrates with the thickness of less than 100 ㎛ were bonded and a jig to form a slope at the edge of the substrate was developed. By developing the scarf welding process, we successfully created a flexible bonding technology that maintains joint's thickness after the process. The tensile strength of the joint was assessed through uniaxial test, and we found that the tensile strength increases as the slope of bonding interface decreases. By conducting stress analysis at the bonding interface with respect to the slope angle, design factor of bonding structure was investigated. These findings suggest that the tensile strength depends on the geometry of the joint, even under the same process conditions, and highlights the significance of considering the geometry of the joint in welding processes.

Expression of lewis antigen in gastric mucosa of children with Helicobacter pylori infection (Helicobacter pylori에 감염된 소아의 위점막에서 Lewis 항원의 발현)

  • Chung, Ju-Young;Lim, Seong Jig;Han, Tae Hee
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.97-103
    • /
    • 2007
  • Purpose : Lewis antigen has been known to have a role in the attachment of H. pylori to the gastric mucosa, but its expression pattern in children with H. pylori infection is still unclear. The recently described blood group antigen-binding adhesin BabA is known to mediate adherence of H. pylori to Lewis B receptors on gastric epithelium. We investigated the expression of Lewis antigen in gastric mucosa of Korean children with H. pylori infection. Methods : The expression of Lewis A ($Le^a$), B ($Le^b$), X ($Le^x$), and Y ($Le^y$) was evaluated by immunohistochemistry in H. pylori positive biopsy specimens from 35 children (antral gastritis in 30, peptic ulcer in 5) and in H. pylori negative specimens from 19 children. PCR assays for cagA and babA2 gene of H. pylori were performed. Results : We confirmed the expression of $Le^a$ in 60%, $Le^b$ in 97%, $Le^x$ in 100%, and $Le^y$ in 100% of the superficial epithelium of the 35 H. pylori positive children. In H. pylori negative patients, $Le^a$, $Le^b$, $Le^x$, and $Le^y$ expression was 52%, 100%, 89%, and 100%, respectively. The cagA gene was detected in 65% and babA2 gene in 25% of 35 patients. No differences in neutrophil activity and chronic inflammation were found according to the presence of cagA and babA2 genes in H. pylori. Conclusion : $Le^b$, $Le^x$ and $Le^y$ antigen were highly expressed in gastric mucosa of Korean children, but they were not associated with the status of H. pylori infection and the positivity of babA2 gene. Further studies for other mucosal receptors and toxins are needed to define the immune responses to H. pylori infection in gastric mucosa of Korean children.

  • PDF

Establishment of optimal conditions for micropropagation by node culture and multiple shoots formation from sucker explants of thornless Blackberry (Rubus fruticosus L. cv. BB21) (가시없는 블랙베리(Rubus fruticosus L. cv. BB21)의 근맹아를 이용한 다경유도와 절간배양을 통한 식물체 증식조건의 확립)

  • Lee, Kang Seop;Kim, Hyo Jin;Park, Dae Hyun;Oh, Seung Cheol;Cho, Han Jig;Kim, Ee Youb
    • Journal of Plant Biotechnology
    • /
    • v.45 no.2
    • /
    • pp.110-116
    • /
    • 2018
  • This study was conducted to develop a simple, rapid, and reliable method for in vitro propagation of disease-free and true-to-type clones from sucker explants of thornless blackberry (Rubus fruticosus L. ${\times}$ R. parvifolius L.). To induce multiple shoots, the sucker explants were sterilized in 1% NaOCl solution, and then were aseptically cultured on the full and 1/2 MS solid medium supplemented with BAP (0.1, 0.5, 1.0, 2.0 mg/L). After six weeks of culture, the highest frequency (85.4%) of shoot formation from sucker explants was obtained on the full-strength MS medium with 1.0 mg/L BAP. Node explants obtained from multiple shoots were cultured on the various media of full- or half-strength of AD, B5, MS, SH, QL, WPM media, respectively. After 30 days of culture, plant growth was good on the half-AD, half-QL medium. After 90 days of culture, plant growth was good on the full MS and full SH medium. The survival rate of the plantlets after transfer to plastic pots containing soil mixture (sand: soil: vermiculite was 1:1:1, vol.) in the greenhouse was 98%. The results indicate that a multiple-shoot procedure can be applied for an efficient mass propagation of Rubus fruticosus L. ${\times}$ R. parvifolius L.

Histiocytic necrotizing lymphadenitis in children : association of human herpes virus 8 and Epstein Barr virus (소아에서의 조직구성 괴사성 림프절염 : human herpesvirus 8과 Epstein Barr virus와의 연관성)

  • Kim, Hyun A;Chung, Ju-Young;Kim, Sang Woo;Lim, Sung Jig;Shin, Haeng Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.875-881
    • /
    • 2006
  • Purpose : The aims of this study were to analyze the clinical characteristics of children with Kikuchi's disease(KD) at a medical center and to investigate the etiologic role of human herpesvirus 8(HHV 8) or Epstein-Barr virus(EBV) in children with KD. Methods : Twenty six children who were diagnosed as KD between Jan. 1998 and Dec. 2005 were included. Medical records were reviewed on the clinical characteristics of children with KD. Follow up data were collected by chart review and telephone contact. Polymerase chain reaction(PCR) was performed in order to detect HHV 8 DNA, and in situ hybridization(ISH) was perfomed in order to detect EBV RNA from 20 lymph node tissues. Results : There were 15 girls and 11 boys with a mean age of 13 years. Posterior cervical lymph nodes were involved in 72 percent(18/25) of the patients. Extracervical lymphadenopathy was associated in one patient. Fever was an associated symptom in 31 percent(8/26) of the patients. Leukopenia was observed in six (46 percent) patients. The cervical lymphadenopathy usually resolved spontaneously within 6 months. Only one patient had a recurrence of lymphadenopathy with fever during follow-up. No children with KD in our series developed systemic lupus erythematosus. HHV 8 DNA was not amplified by nested PCR in any of the cases, and all cases were negative for EBV RNA by ISH. Conclusion : KD should be differentiated as a cause of cervical lymphadenopathy in children. HHV 8 and EBV may not play major causative roles in KD in children.

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

The Effects of Bark on Heavy Metal Adsorption I. The Effects of Pine and Oak Barks on Adsorption of $Fe^{++}$ and $Ni^{++}$ in Wastewater (수피(樹皮)에 의(依)한 중금속(重金屬) 흡착효과(吸着效果) I. 수피(樹皮)를 이용(利用)한 폐수(廢水)중 $Fe^{++}$$Ni^{++}$의 제거(除去) 효과(效果))

  • Kim, Kyung-Jig;Paik, Ki-Hyon
    • Korean Journal of Environmental Agriculture
    • /
    • v.5 no.1
    • /
    • pp.55-60
    • /
    • 1986
  • The objective of this study was to investigate the physical and chemical factors of Pinus densiflora SIEB. et ZUCC. and Quercus mongolica Fisher barks affecting on the adsorption of heavy metals. The results obtained can be summarized as follows: 1. With decreasing the particle size of bark, the adsorption rate of two heavy metal ions were increased. In case of using same particle size, the adsorption of $Fe^{++}$, and $Ni^{++}$ by Quercus bark showed higher than by Pinus bark. 2. The effect of untreated bark on the adsorption of heavy metal was more or less 5% higher than that of HCHO-treated bark in both species. But the color absorbances of the filtrates from HCHO-treated Pinus and Quercus barks were 5.8 and 11.8 times smaller than those of the filtrate from untreated Pinus and Quercus barks, respectively. 3. The maximum adsorption of $Fe^{++}$, and $Ni^{++}$ by bark was shown after 30 min. of the reaction. 4. With increasing the concentration of heavy metal, the amount of adsorption by bark was increased, but the adsorption ratio were decreased. 5. The maximum adsorption of $Fe^{++}$, and $Ni^{++}$ appeared at final pH of $4{\sim}5$, and pH of $3.6{\sim}4.0$ in filtrate, respectively. 6. With increasing the bark weight per a given heavy metal solution, the adsorption ratio were increased, but the amount of adsorption per gram of bark was the highest on the reaction with 2g of bark in a economical sense showing the amount of adsorption of 21mg $Fe^{++}$/g and 7mg $Ni^{++}$/g of Pinus bark, 36mg $Fe^{++}$/g and 9mg $Ni^{++}$/g of Quercus bark, respectively.

  • PDF

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system (지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구)

  • Lee, Sang-Hyeok;Ahn, Jin-Soo;Kim, Myung-Ho;Lim, Bum-Soon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.235-242
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the fracture behavior of Zironia, glass infiltrated Alumina and PFM full crown system. Materials and methods: Fifteen crowns for each of 3 experimental groups (Zironia, glass infiltrated Alumina and PFM full crown) were made by the conventional method. The crowns mounted on the testing jig were inclined in 30 degrees to the long axis of the tooth and the universal testing machine was used to measure the fracture strength. Results: 1. The mean fracture strengths were $588.3{\pm}49.6MPa$ for zirconia system, $569.1{\pm}61.8MPa$ for PFM system and $551.0{\pm}76.5MPa$ for glass-infiltrated alumina system (P>.05). 2. The mean shear bond strengths were $25.5{\pm}5.6MPa$ for zirconia system, $38.9{\pm}5.0MPa$ for Ni-Cr alloy system and $39.4{\pm}5.1MPa$ for glass-infiltrated alumina system. 3. The chemical bonding was observed at interfaces between PFM or glass-infiltrated alumina and veneering porcelain, however, no chemical bonding was observed at interface between zirconia and veneering porcelain. Conclusion: With the study, the fracture strengths of PFM crown system had a higher fracture strength than conventional zirconia system crown and glass-infiltrated alumina crowns. and than the shear bond strengths glass-infiltrated alumina system had a higher shear bond strength than conventional PFM system and zirconia system.