• 제목/요약/키워드: jerk

검색결과 154건 처리시간 0.023초

Correlation Analysis between Dance Experience and Smoothness of Dance Movement by Using Three Jerk-Based Quantitative Methods

  • Park, Yang Sun
    • 한국운동역학회지
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2016
  • Objective: The aim of this study is to investigate the association between dance experience and smoothness of hand trajectory during dance by using three jerk-based quantitative methods (integrated squared jerk, mean squared jerk, and dimensionless jerk). Methods: Eleven Korean traditional dancers whose experience of dancing ranged from 5 years to 20 years participated in this study. Dancers performed the Taeguksun motion in Korea traditional dance. Six infrared cameras were used to capture the movement of the hands of the dancers. The smoothness of hand movement was calculated using three jerk-based methods. Results: With regard to the smoothness of the right hand, dance experience was significantly correlated with dimensionless jerk (r=0.656, p=0.028), while dance experience was not significantly correlated with integrated squared jerk (r=0.581, p=0.552) and mean squared jerk. With regard to the smoothness of the left hand, there was no correlation between dance experience and any of the three jerk values. Conclusion: Our results showed that individuals with more dance experience performed the task more smoothly. This study suggests that dimensionless jerk should be used as a predictor for smoothness in dance movement. Thus, our results support the idea that smoothness is an aspect of movement quantity distinct from speed and distance.

통증성 Jerk 검사: 견관절 후하방 불안정성의 보전적 치료 결과의 예측 (Painful Jerk Test: A Predictor of Success in Nonoperative Treatment of Posteroinferior Instability of the Shoulder)

  • 김승호;정웅교;박재철;박준식;오일빈
    • Clinics in Shoulder and Elbow
    • /
    • 제7권2호
    • /
    • pp.57-64
    • /
    • 2004
  • The purposes of this study were to evaluate the presence or absence of pain with the jerk test as a predictor of the success of nonoperative treatment for posteroinferior instability of the shoulder and to identify pathologic lesion responsible for the pain in the jerk test. Eighty-nine shoulders(81 patients), which had posteroinferior instability with positive posterior clunk in the jerk test, were nonoperatively treated. The patients were divided into two groups with respect to the presence of pain in the jerk test: painless jerk group(54 shoulders) and painful jerk group(35 shoulders). Response to the nonoperative treatment was evaluated after at least 6 months rehabilitation program. Patients who did not respond to the rehabilitation underwent arthroscopic examination to identify any pathologic lesion. The painful jerk group had higher failure rate with nonoperative treatment (p<0.001). In the painless jerk group, fifty shoulders (93%) responded to rehabilitation program after a mean of 4 months. Four shoulders(7%) were unresponsive to the rehabilitation. In the painful jerk group, five shoulders(16%) were successful with the rehabilitation while the other thirty shoulders(84%) failed. All 34 shoulders, which were unresponsive to the rehabilitation, had a variable degree of posteroinferior labral lesions. In conclusion, the jerk test is a hallmark for predicting the prognosis of nonoperative treatment in the posteroinferior instability. Shoulders with symptomatic posteroinferior instability and a painful jerk test have posteroinferior labral lesion.

초음파 센서를 이용한 담적(痰積)진단시스템의 설계와 응답특성 (The Development and Response Characteristic Analysis of Dam Jerk Diagnosis System Using Ultrasonic Sensor)

  • 이용흠;신태민;이균정
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권4호
    • /
    • pp.189-194
    • /
    • 2006
  • Dam jerk causes a chronic stomach disorder. The number of the patient of the Dam jerk increase in these days. However, there are no objective and quantitative study for a diagnosis of Dam jerk. Therefore, we designed diagnosis system using ultrasonic response signal for a diagnosis of Dam jerk. It was used to collect the response signal that is reflected at Dam jerk region of the abdominal. And then, the response signal at the Dam jerk region is 20% higher than the normal region. In the result. we could prove the reliability of the system.

Jerk 모델을 사용한 급격한 기동표적 추적필터의 성능 해석 (Performance Analysis of the Tracking Filter Employing Jerk Model for Highly Maneuvering Targets)

  • 주재석;임상석
    • 한국항행학회논문지
    • /
    • 제4권1호
    • /
    • pp.50-66
    • /
    • 2000
  • 표적 추적에서 기동은 오랫동안 다루기 어려운 문제로 여겨져 왔다. 급격한 가속도 변화와 같은 표적의 기동이 발생하면 추적필터는 그 정상적인 예측치를 산출해내기 어렵기 때문이다. 이러한 표적기동을 다루기 위해 몇가지 기법들이 제시되었는데 천연색 잡음, IE, VD(가변 차원), IMM(다중모델), jump형 프로세스 및 jerk 모델로 나타내는 것 등이다. 본 논문에서는 최근에 관심을 끌고 있는 jerk 모델(가속도의 미분으로 기동을 표시함)에 대한 추적성능을 분석한다. 먼저 jerk를 포함하는 칼만필터를 3차원 문제에 대해 기술한다. 이 필터를 사용하여 시정수 변화에 대한 추적성능을 Monte-Carlo 시뮬레이션을 통해 해석한다. 특히, jerk 모델의 경우 과도응답 성능이 저하되므로 이에 대한 해석을 별도로 추가하였다.

  • PDF

Analysis, Control, and Synchronization of a 3-D Novel Jerk Chaotic System with Two Quadratic Nonlinearities

  • VAIDYANATHAN, SUNDARAPANDIAN
    • Kyungpook Mathematical Journal
    • /
    • 제55권3호
    • /
    • pp.563-586
    • /
    • 2015
  • In this research work, a seven-term 3-D novel jerk chaotic system with two quadratic nonlinearities has been proposed. The basic qualitative properties of the novel jerk chaotic system have been described in detail. Next, an adaptive backstepping controller is designed to stabilize the novel jerk chaotic system with two unknown parameters. Moreover, an adaptive backstepping controller is designed to achieve complete chaos synchronization of the identical novel jerk chaotic systems with two unknown parameters. MATLAB simulations have been shown in detail to illustrate all the main results developed for the 3-D novel jerk chaotic system.

Global Minimum-Jerk Trajectory Planning of Space Manipulator

  • Huang Panfeng;Xu Yangsheng;Liang Bin
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권4호
    • /
    • pp.405-413
    • /
    • 2006
  • A novel approach based on genetic algorithms (GA) is developed to find a global minimum-jerk trajectory of a space robotic manipulator in joint space. The jerk, the third derivative of position of desired joint trajectory, adversely affects the efficiency of the control algorithms and stabilization of whole space robot system and therefore should be minimized. On the other hand, the importance of minimizing the jerk is to reduce the vibrations of manipulator. In this formulation, a global genetic-approach determines the trajectory by minimizing the maximum jerk in joint space. The planning procedure is performed with respect to all constraints, such as joint angle constraints, joint velocity constraints, joint angular acceleration and torque constraints, and so on. We use an genetic algorithm to search the optimal joint inter-knot parameters in order to realize the minimum jerk. These joint inter-knot parameters mainly include joint angle and joint angular velocities. The simulation result shows that GA-based minimum-jerk trajectory planning method has satisfactory performance and real significance in engineering.

최소저크궤적과 X축-스웨이를 이용한 4족 보행로봇의 안정적 걸음새 연구 (Study on Stable Gait Generation of Quadruped Walking Robot Using Minimum-Jerk Trajectory and Body X-axis Sway)

  • 이동구;신우현;김태정;이정호;이영석;황헌;최선
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.170-177
    • /
    • 2019
  • 본 논문에서는 4족복 보행 로봇의 주행 안정성을 개선하기 위한 3가지 이론을 제시한다. 첫 번째는 Minimum-Jerk Trajectory를 이용하여 다리궤적을 최적화 시킨다. 두 번째는 본 논문에서 새롭게 제시한 사인파와 기존의 방식인 LSM을 Jerk값에 근거하여 비교한다. 셋째는 ADAMS-MATLAB co-simulation을 이용하여 반복적인 로봇 시뮬레이션을 통해 스웨이의 최적 보폭을 계산한다. 위의 과정을 통해 로봇의 보행 개선점을 기존의 이론과 비교하여 나타내었다. 첫 번째로 정 보행시 몸체와 타원형태의 다리 끝의 움직임에 Minimum-Jerk trajectory를 사용하여 다리궤적이 급격하게 변하는 지점의 평균 기울기를 최소 1.2에서 최대 2.9까지 감소시켜 지면에 다리 끝점이 도달할 때 충격을 최소화하여 안정성을 증가 하였다. 두 번째로 기존 LSM(Longitudinal Stability Margin)기법과 본 논문에서 제시한 사인파형 Sway를 사용하여 비교한 결과 평균 Jerk를 Z축에서 0.019, X축에서 0.457, Y축에서 0.02, 3D는 0.479 만큼 감소 시켰다. 특히 X축 Jerk는 크게 감소 하였다. 셋째로 로봇이 최소 Jerk 값으로 보행하기 위한 최적의 보폭의 길이를 상기 분석을 통해 도출하였으며 그 결과 20cm보폭 길이가 가장 안정적이었다.

Vibration Suppression Control for Mechanical Transfer Systems by Jerk Reduction

  • Hoshijima, Kohta;Ikeda, Masao
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권6호
    • /
    • pp.614-620
    • /
    • 2007
  • This paper considers vibration suppression of a mechanical transfer system, where the work is connected with the hand flexibly. We adopt the idea of jerk reduction of the hand. From the equation of motion, we first derive a state equation including the jerk and acceleration of the hand, but excluding the displacement and velocity of the work. Then, we design optimal state feedback for a suitable cost function, and show by simulation that jerk reduction of the hand is effective for vibration suppression of the work and improvement of the settling time. Since state feedback including the jerk and acceleration is not practical, we propose a computation method for optimal feedback using displacements and velocities in the state only.

보행속력과 동작의 부드러움과의 상관관계에 관한 연구 (Relationship between Walking Speed and Smoothness of Movement)

  • 탁계래;한영민;최진승;이정한;임영태;전재훈;박상균;;박승하
    • 한국운동역학회지
    • /
    • 제16권1호
    • /
    • pp.11-17
    • /
    • 2006
  • The purpose of this study was to evaluate the smoothness of movement during various walking speeds. Based on the maximum smoothness theory (or the minimum jerk theory), we hypothesized that the walking speed at the maximum smoothness (or minimum normalized jerk) is the same as that at the minimum energy consumption. Eleven university students participated in treadmill walking experiment with 11 different walking speeds (1.11, 1.19, 1.25, 1.33, 1.56, 1.78, 1.9, 2, 211, 233, and 2.47m/sec). Normalized jerk at 15 markers and the center of mass was calculated. Results showed that there existed a quadratic relationship between the normalized jerk of the vertical direction at the center of mass and the walking speed As the walking speed increased, the normalized jerk of all directions at the heel decreased Our hypothesis that the previously published energetically optimal walking speed ($1.25\;{\sim}\;1.4m/s$) is the same as the minimum jerk speed (1.78m/s) did not agree with this result. The minimum normalized jerk at the center of mass occurred at the walking speed of 1.78m/s which was the preferred walking speed by subjects' questionaries. Further studies concerning the energetically optimal walking speed, preferred walking speed, and walk-run transition speed or run-walk transition speed are necessary based on actual energy consumption experiment and various multi-dimensional analysis.

고속 LCD 이송 시스템의 진동감소를 위한 Finite Jerk 적용 가속도 최적화 (Acceleration Optimization of a High-speed LCD Transfer Crane Using Finite Jerk)

  • 송태진;홍대선;김호종;방덕제;정원지
    • 한국정밀공학회지
    • /
    • 제23권3호
    • /
    • pp.110-117
    • /
    • 2006
  • This paper presents the acceleration optimization of a high-speed LCD (Liquid Crystal Display) transfer system for the minimization of vibration. To reduce vibration is one of key requirements for the dynamic control of a high-speed LCD transfer system. In this paper, the concept of finite jerk (the first derivative of acceleration) has been introduced for realizing input acceleration. The profile of finite jerk has been optimized using a genetic algorithm so that vibration effect can be minimized. In order to incorporate a genetic algorithm, the dynamic model of a LCD transfer system which is realized by using the ADAMS software has been linked to the simulation system constructed by the MATLAB. The simulation results illustrated that the duration of finite jerk can be optimized so as to minimize the magnitude of vibration. It has been also shown that the acceleration optimization with finite jerk can make the high-speed motion of a LCD transfer system result in low vibration, compared with the conventional motion control with trapezoidal velocity profile.