• 제목/요약/키워드: isotope dilution method

검색결과 85건 처리시간 0.024초

Inspection of the Fragmentation Pathway for Thiamethoxam

  • Son, Sunwoong;Kim, Byungjoo;Ahn, Soenghee
    • Mass Spectrometry Letters
    • /
    • 제8권3호
    • /
    • pp.65-68
    • /
    • 2017
  • Thiamethoxam is one of the main suspect in honeybee colony collapse disorder (CCD). Due to this reason, thiamethoxam including imidacloprid and clothianidin has been banned for two years in some Europe countries. The CCD phenomenon has also been reported in Korea. Regarding this issue and needs, a new project has started to develop the method for the quatitation of thiamethoxam using isotope dilution mass spectrometry (IDMS). In the process of optimization for the IDMS method with thiamethoxam and $thiamethoxam-d_3$, we observed that the fragment peaks did not correspond to the fragmentation pathway as published elsewhere. Here, we proposed a candidate fragmentation pathway. To validate the proposed fragmentation pathway, another isotope analogue, $thiamethoxam-d_4$, was introduced and the MS/MS spectra of both isotope analogues were compared. In addition, the MS/MS/MS spectra of thiamethoxam were inspected for more evidence of the candidate pathway. Those spectra indicated that the proposed fragmentation pathway could be used to assign the fragment peaks of thiamethoxam.

Determination of Mercury in Fly Ash by Using Flow Injection Cold Vapor Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Suh, Jung-Ki;Min, Hyung-Sik;Kamruzzaman, Mohammad;Lee, Sang-Hak
    • Mass Spectrometry Letters
    • /
    • 제3권2호
    • /
    • pp.58-61
    • /
    • 2012
  • A method based on flow injection-isotope dilution-cold vapor-inductively coupled plasma mass spectrometry (FI-IDCV-ICP/MS) has been applied to determine trace level of mercury in fly ash. $^{200}Hg$ isotopic spike was added to 0.25 g of BCR176R fly ash and then decomposed by microwave digestion procedure with acid mixture A (8 mL $HNO_3$ + 2 mL HCl + 2 mL HF) and acid mixture B (8 mL $HNO_3$ + 2 mL $HClO_4$ + 2 mL HF) for applying IDMS. Mercury cold vapor was generated by using reductant solution of 0.2% (w/w) $NaBH_4$ and 0.05% (w/w) NaOH. The measurements of n($^{200}Hg$)/n($^{202}Hg$) isotope ratio was made using a quadrupole ICP/MS system. The accuracy in this method was verified by the analysis of certified reference material (CRM) of fly ash (BCR 176R). The indicative value of Hg in BCR 176R fly ash was $1.60{\pm}0.23$ mg/kg (k = 2). The determined values of Hg in BCR 176R fly ash by the method of FI-CV-ID-ICP/MS described in this paper were $1.60{\pm}0.24$ mg/kg (k = 3.18) and the analysis results were in well agreement with the indicative value within the range of uncertainty.

Comparison of QuEChERS and Solid Phase Extraction for Accurate Determination of Pesticide Residues in Kimchi Cabbage and Strawberry using Isotope Dilution Mass Spectrometry

  • Seonghee Ahn;Kebede Gebeyehu Mekete;Byungjoo Kim
    • Mass Spectrometry Letters
    • /
    • 제14권4호
    • /
    • pp.178-185
    • /
    • 2023
  • QuEChERS is used worldwide as a universal sample preparation method with many benefits, such as being quick, easy, cheap, effective, rugged and safe. This study examined whether QuEChERS can be employed in isotope dilution mass spectrometry (ID-MS) for accurate analysis of pesticides in food. The ratios of fortified values and measured values of malathion and fenitrothion using the QuEChERS method were compared with those using the solid phase extract (SPE) method which was previously used in this laboratory. The separations of the two pesticides on DB-5MS and VF-1701MS columns were compared. Malathion and fenitrothion were fortified into kimchi cabbage and pretreated with the QuEChERS method and the SPE method. The results obtained using the DB-5MS column varied according to the sample preparation method, column and pesticide level. Using the VF-1701 column, ratios were 98-102% by both QuEChERS and Carb/NH2 SPE method for all fortification level. Malathion and fenitrothion were fortified into strawberry samples for comparison with kimchi cabbage. The results for the strawberry samples indicated that the ratios were not influenced by the sample preparation methods or GC column. The QuEChERS method could be acceptable in the ID-MS method for pesticide residue analysis in food, however other conditions should be carefully considered for accurate determination, such as the column, amount of analyte and food matrix.

후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구 (Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS)

  • 주민규;박명순;박용남
    • 분석과학
    • /
    • 제27권3호
    • /
    • pp.140-146
    • /
    • 2014
  • 후 컬럼 동위원소 희석법(PCID, post column isotope dilution)을 HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry)에 적용한 정량법에서 내부 표준물을 동시에 사용하여 정확도와 정밀도를 개선하였다. 전통적인 여러 정량법과 후 컬럼 동위원소 희석법을 비교하여 볼 때에 PCID의 경우에 컬럼내에서 발생하는 오차가 가장 큰 요인으로 작용하였음을 알 수 있었다. PCID에서 내부 표준물을 사용하여 컬럼내에서의 손실에 대한 오차를 효과적으로 보정하고 정확도와 정밀도를 개선할 수 있었다. 셀레늄 화학종인 SeMet을 시료로 사용하고 내부 표준물로 MeSecys 또는 $Se^{4+}$를 이용한 결과, 사용하지 않은 경우와 비교하면 상대오차는 각 각 31%와 13%에서 모두 1% 대로 낮아져 정확도가 크게 개선되었으며, 상대 표준편차는 5.1%와 6.9%에서 각각 1.5%와 0.2%로 정밀도 또한 크게 개선되었다. PCID에서 내부 표준물을 사용하였을 때의 정량분석법의 장점을 다른 분석법과 비교 토의하였다.

Analysis of the Irradiated Nuclear Fuel Using the Heavy Atom and Neodynium Isotope Correlations with Burnup

  • Kim, Jung-Suk
    • Nuclear Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.327-335
    • /
    • 1997
  • The correlation of isotope composition of uranium, plutonium and neodymium with the burnup in M uranium dioxide fuel has been investigated experimentally. The total and fractional($^{235}$ U) burnup were determined by Nd-148 and, U and Pu mass spectrometric method respectively. The isotope compositions of these elements, after their separation from the fuel samples were measured by mass spectrometric. The content of the elements in the irradiated fuel ore determined by isotope dilution mass spectrometric method using $^{233}$ U, $^{242}$ Pu and $^{150}$ Nd as spikes. The content of plutonium in the irradiated fuel was expressed by the correlation with uranium isotopes. The correlations between isotope compositions themselves and the total and fractional burnup ore compared with those calculated from ORIGEN2 code.

  • PDF

Quantitative Analysis of Trace pp'-DDE in Corn Oil by Isotope Dilution Mass Spectrometry : Uncertainty Evaluations

  • 김병주;김달호;최종오;소헌영
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권8호
    • /
    • pp.910-916
    • /
    • 1999
  • A current interest in chemistry concerns traceability of analytical measurements to the International System of Units (SI) and the proper estimation of their uncertainties in accordance with the internationally agreed guide provided by the International Organization for Standardization (ISO). Isotope dilution mass spectrometry (IDMS) is regarded as a primary method, which make the measurement results traceable to SI units without significant empirical correction factors. Our laboratory, as the national standards institute of Korea, participated in an intercomparison of environmental analysis, pp'-DDE in corn oil, which was organized by the CCQM under supervision of the CIPM to test feasibility of IDMS as a primary method for the trace analysis of organic compounds. In this report, we provide basic equations used for the calculation of the concentration of the analyte in a sample and a precise description of the processes for the evaluation of the uncertainties of the measurement results. Also, we report the experimental conditions adopted to improve the accuracy of the IDMS measurement. The principles contained in ??Guide to the Expression of Uncertainty in Measurement'' provided by ISO are followed for the uncertainty evaluation.

동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석 (Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry)

  • 서정기;우진춘;민형식;임명철
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

ANALYSIS OF HIGH BURNUP PRESSURIZED WATER REACTOR FUEL USING URANIUM, PLUTONIUM, NEODYMIUM, AND CESIUM ISOTOPE CORRELATIONS WITH BURNUP

  • KIM, JUNG SUK;JEON, YOUNG SHIN;PARK, SOON DAL;HA, YEONG-KEONG;SONG, KYUSEOK
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.924-933
    • /
    • 2015
  • The correlation of the isotopic composition of uranium, plutonium, neodymium, and cesium with the burnup for high burnup pressurized water reactor fuels irradiated in nuclear power reactors has been experimentally investigated. The total burnup was determined by Nd-148 and the fractional $^{235}U$ burnup was determined by U and Pu mass spectrometric methods. The isotopic compositions of U, Pu, Nd, and Cs after their separation from the irradiated fuel samples were measured using thermal ionization mass spectrometry. The contents of these elements in the irradiated fuel were determined through an isotope dilution mass spectrometric method using $^{233}U$, $^{242}Pu$, $^{150}Nd$, and $^{133}Cs$ as spikes. The activity ratios of Cs isotopes in the fuel samples were determined using gamma-ray spectrometry. The content of each element and its isotopic compositions in the irradiated fuel were expressed by their correlation with the total and fractional burnup, burnup parameters, and the isotopic compositions of different elements. The results obtained from the experimental methods were compared with those calculated using the ORIGEN-S code.

동위원소희석 액체크로마토그래피/질량분석법에 의한 혈청 내 콜레스테롤의 정량 (Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry)

  • 신혜선;이화심;이계호
    • 분석과학
    • /
    • 제21권6호
    • /
    • pp.502-509
    • /
    • 2008
  • 혈청 내 콜레스테롤을 정량분석하기 위한 일차분석법으로 동위원소희석 액체크로마토그래피/질량분석법(isotope dilution liquid chromatography/mass spectrometry)을 사용하였다. 콜레스테롤은 Thermo ODS hypersil $C^{18}$ 칼럼을 사용하여 분리하였고, 이동상은 100% 메탄올, 유속은 0.3 mL/min으로 하였다. 콜레스테롤과 콜레스테롤-$3,4-13C_2$$[M-H_2O+H]^+$이온에 해당하는 m/z 369.4와 371.3에서 모니터링하여 정량에 합당한 크로마토그램을 얻을 수 있었다. 방법의 유효성을 증명하기 위해서 NIST SRM 909b를 분석한 결과 인증값과 불확도 범위 내에서 일치하는 것을 확인하였다. 이 방법을 바탕으로 혈청 인증표준 물질 4 종류를 제조하여 인증을 실시하였다. 인증 결과, 반복성의 상대표준오차는 0.1~0.8%, 재현성의 경우 0.24%이하, 확장 불확도는 95% 신뢰도구간에서 약 1.43%로 나타났다.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권5호
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.