Browse > Article
http://dx.doi.org/10.5806/AST.2008.21.6.502

Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry  

Shin, Hyesun (Department of Chemistry, Chungnam National University)
Lee, Hwashim (Health Metrology Center, Division of Quality of Life, Korea Research InstituteStandards and Science)
Lee, Gaeho (Department of Chemistry, Chungnam National University)
Publication Information
Analytical Science and Technology / v.21, no.6, 2008 , pp. 502-509 More about this Journal
Abstract
An ID LC/MS (isotope dilution liquid chromatography/mass spectrometry) was used as a primary method for the quantitative analysis of cholesterol in human serum. The separation of cholesterol was carried out by Thermo ODS hypersil $C^{18}$ column. The mobile phase was 100% methanol, and flow rate was $0.3m{\ell}/min$. Cholesterol and cholesterol-$3,4-13C_2$ were monitored at m/z 369.4 and 371.3, which correspond to $[M-H_2O+H]^+$ respectively. In order to verify the measurement method, NIST SRM 909b was analyzed. The results agreed well with certified values within uncertainty. The four kinds of serum certified reference material were prepared and certified. The repeatabilities of measurement were ranged from 0.1 to 0.8% (RSD), which were relatively good. The reproducibility between independent measurement run was below 0.24% (RSD). The expanded uncertainty was about 1.43% within the 95% confidence interval.
Keywords
cholesterol; ID LC/MS; primary method; traceability;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 R. Kock, B. Delvoux and H. Greiling, Clin. Chem., 43(10), 1896-1903(1997)   PUBMED
2 O. Pelletier, L. A. Wright and W. C. Breckenridge, Clin. Chem., 33(8), 1403-1411(1987)   PUBMED
3 J. T. Bernert, Jr., J. R. Akins, G. R. Cooper, A. K. Poulose, G. L. Myers and E. J. Sampson, Clin. Chem., 37(12), 2053-2061(1991)   PUBMED
4 류병호, '콜레스테롤.동맥경화', 9-34, 신지서원, 대 한민국, 1998
5 A. Takatsu and S. Nishi, Anal. Chem., 60, 2237-2239 (1988)   DOI   ScienceOn
6 G. L. Myers, M. M. Kimberly, P. P. Waymack, S. J. Smith, G. R. Cooper and E. J. Sampson, Clin. Chem., 46(11), 762-1772(2000)
7 P. S. Bachorik, J. W. Ross, Clin. Chem., 41(10), 1414-1420(1995)   PUBMED
8 I. W. Duncan and P. H. Culbreth and C. A. Burtis, J. Chromatogr., 162, 281-292(1979)   DOI   ScienceOn
9 P. Ellerbe., S. Meiselman and L. T. Sniegoski, Anal. Chem., 61, 1718-1723(1989)   DOI   ScienceOn
10 H.S. Lee and S.R. park, Anal. sci. & tech., 18(7), 271-277(2005)
11 P. Ellerbe, G. L. Myers, G. R. Cooper, H. S. Hertz, L. T. Snlegoskl, M. J. Welch, E. White and V, Clin. Chem., 36(2), 370-375(1990)   PUBMED
12 ISO guide ISBN 92-67-10188-9; Guide to the expression of uncertainty in measurement
13 A. Takatsu and S. Niahl, Clin. Chem., 33(7) 1113-1117 (1987)   PUBMED
14 소헌영 외, '물질량 측정 정확도 향상 연구', KRISS/ IR-2000-022, 419-443, 한국표준과학연구원, 대한민 국, 1999
15 I. Bjrkhem, R. blomstrand and L. svensson, Clin. Chim. Acta, 54, 185-193(1974)   DOI   ScienceOn
16 L. M. Thienpont, A. P. De Leenheer, D. Stckl and H. Reinauer, Clin. Chem., 39(6), 1001-1006(1993)   PUBMED
17 M. Nakamura, S. Sato and T. Shimamaoto, J. Ather. and Throm., 10(3), 145-153(2003)   DOI
18 管野道廣, 今泉己, 李相榮, 崔龍淳, '콜레스테롤', 17- 50, 新光出版社, 대한민국, 1990
19 G. R. Cooper, S. J. Smith, I. W. Duncan, A. Mather, W. D. Fellows, T. Foley, I. D. Frantz, J. B. Gill, T. A. Grooms, I. Hynie, R. Laessig, F. A. LoBasso, J. Martin, H. Naito, H. A. Newman, L. Sideman, J. H. Turner and D. Williams, Clin. Chem., 32(6), 921-929(1986)   PUBMED
20 S. Usui, M. Nakamura, K. Jitsukata, M. Nara, S. Hosaki and M. Okazaki, Clin. Chem., 46(1), 63-72(2000)   PUBMED
21 P. Gambert, C. Lallemant and A. Archambault, J. chromatogr., 162, 1-6(1979)   DOI   ScienceOn
22 C. S. J. Wolff Briche, D. Carter and K. S. Webb, Rapid Commun. Mass Spectrom., 16, 848-853(2002)   DOI   ScienceOn