Browse > Article
http://dx.doi.org/10.5806/AST.2014.27.3.140

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS  

Joo, Mingyu (Department of Chemistry Education, Korea National University of Education Cheng-Won)
Park, Myungsun (Department of Chemistry Education, Korea National University of Education Cheng-Won)
Pak, Yong-Nam (Department of Chemistry Education, Korea National University of Education Cheng-Won)
Publication Information
Analytical Science and Technology / v.27, no.3, 2014 , pp. 140-146 More about this Journal
Abstract
An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.
Keywords
internal standard; post column isotope dilution; species unspecific ID; HPLC-ICP/MS;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 K. Polec-Pawlak, D. Schaumlofel, J. Szpunar, A. Prange and R. Lobinski, J. Anal. At. Spectrom., 17, 908-913 (2002).   DOI   ScienceOn
2 H. G. Infante, K. V. Campenhout, D. Schaumlofel, R. Blust and F. C. Adams, Analyst, 128, 651-660 (2003).   DOI   ScienceOn
3 D. Schaumlofel, A. Prange, G. Marx, K. G. Heumann and P. Brater, Anal. Bioanal. Chem., 55, 372-378 (2002).
4 H. Jang, H. Min, J. Lee and Y. Pak, Anal Sci and Technol., 26, 182-189 (2013).   DOI   ScienceOn
5 E. Kim, M. Joo, H. Kwon and Y. Pak, Anal Sci and Technol., 26, 307-314, (2013).   DOI   ScienceOn
6 M. Kotrebai, J. Tyson, E. Block and P. C. Uden, J. of Chromatography A, 866 51-63, (2000).   DOI   ScienceOn
7 M. Fernanda Gine and A. Paula Packer, J. Braz. Chem. Soc., 21, 575-589 (2010).   DOI   ScienceOn
8 C. Swart, O. Rienitz and D. Schiel, Talanta, 83, 1544-1551 (2011).   DOI   ScienceOn
9 K. G. Heumann, Int. J. Mass. Spectrom. Ion Process., 118/119, 575-592 (1992).   DOI   ScienceOn
10 L. Rottmann, K.G. Heumann, Fresenius J. Anal. Chem., 350, 221-228, (1994).   DOI
11 H. A. Meyer, B. Hollenbach, C. Stephan, T. Endermann, N. G. Morgenthaler, H. Cammann, J. Kohrle, K. Jung and L. Schomburg, Cancer Epidemiol Biomarker Prev., 18(9), 2386-2390 (2009).   DOI   ScienceOn
12 P. Rodrigez-Gonzalez, J. M. Marchante-Gayon, J. I. Garcia-Alonso and A. Sanz-Medel, Spectrochimica Acta, 60B, 151-207 (2005).
13 H. G. Infante, K. V. Campenhout, R. Blust and F. C. Adams, J. Chromatogr. A, 184, 1121-1129 (2006).
14 A. Rodriuez-Cea, M. R. Fernadez, E. B. Gonzalez, B. A. Fernadez and A. Sanz-Medel, J. Anal. At. Spectrom., 18, 1357-1362 (2003).   DOI   ScienceOn
15 A. Rodriuez-Cea, M. R. Fernadez, J. I. Garci-Alonso and A. Sanz-Medel, J. Anal. At. Spectrom., 21, 270-278 (2006).   DOI   ScienceOn
16 K. V. Campenhout, H. G. Infante, G. Goemans, C. Belpaire, F. C. Adams, R. Blust and L. Bervoets, Sci. Total Environ., 194, 379-386 (2008).
17 J. Jeong, J. Lee and Y. Pak, Bull. Kor. Chem. Soc., 34, 3817-3824 (2013).   DOI   ScienceOn
18 O. Rienitz A. Pramann and D. Schie, International Journal of Mass Spectrometry, 289, 47-53 (2010).   DOI   ScienceOn