• Title/Summary/Keyword: ionic

Search Result 3,049, Processing Time 0.028 seconds

Preparation and Characterization of Porous CeO2 Using Ionic Liquids (이온성액체를 이용한 다공성 산화세륨 합성)

  • Yoo, Kye Sang;Lee, Bu Ho
    • Applied Chemistry for Engineering
    • /
    • v.20 no.3
    • /
    • pp.313-316
    • /
    • 2009
  • Synthesis of porous $CeO_2$ particles was investigated using various ionic liquids (ILs) as an effective template. The pore structure and crystalline phase of $CeO_2$ particles was affected significantly by the composition of ionic liquids. The strength of the hydrogen bonds on the anion part of ionic liquid was an essential factor to form the pore architecture of $CeO_2$ particles. Moreover, the length of alkyl group on the cation part of ionic liquid determined the pore size and surface area of $CeO_2$ particles. Among the ionic liquids, it was found that 1-Buthyl-3-methylimidazolium hexafluorophosphate ([Bmim][PF6]) was the most effective ionic liquid to synthesize the porous $CeO_2$ particle.

Effect of Ionic Liquid on the Kinetics of Peroxidase Catalysis

  • Lee, Yoon-Mi;Kwon, O-Yul;Yoo, Ik-Keun;Ryu, Keun-Garp
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.600-603
    • /
    • 2007
  • The effect of a water-miscible ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate $([BMIM][BF_4])$, on the horseradish peroxidase (HRP)-catalyzed oxidation of 2-methoxyphenol (guaiacol) with hydrogen peroxide $(H_2O_2)$ was investigated. HRP maintains its high activity in the aqueous mixtures containing various concentrations of the ionic liquid and even in 90% (v/v) ionic liquid. In order to minimize the effect of solution viscosity on the kinetic constants of HRP catalysis, the enzymatic reactions in the subsequent kinetic study were performed in water-ionic liquid mixtures containing 25% (v/v) ionic liquid at maximum. As the concentration of $[BMIM][BF_4]$ increased for the oxidation of guaiacol by HRP, the $K_m$ value increased with a slight decrease in the $K_{cat}$ value: The $K_m$ value increased from 2.8 mM in 100% (v/v) water to 22.5mM in 25% (v/v) ionic liquid, indicating that ionic liquid significantly weakens the binding affinity of guaiacol to HRP.

Characterization of Ionic Liquid Contained Polymer Gel Electrolyte (이온성 액체를 함유한 고분자 겔 전해질의 특성연구)

  • Ryu, Sang-Woog;Song, Eui-Hwan
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • Acrylate polymer gel electrolytes containing N-methoxymethyl-N-methylpyrrolidium bis (trifluoro - methansulfonyl) imide (MPSI) as an ionic liquid were synthesized by solution polymerization in the presence of carbonate solvent. ionic conductivity and mechanical properties of the polymer gel electrolytes were investigated by impedance analyzer and universal testing machine as a function of the amount of polymer, and ionic liquid and type of crosslinker. The maximum ionic conductivity of polymer gel electrolytes was 0.8 mS/cm at $25^{\circ}C$ with 15 wt% of polymer, 30 wt% of ionic liquid and 5 wt% of crosslinker. The mechanical analysis showed that the tensile strength of polymer gel electrolytes increased with additional polymer contents and had the maximum value of 0.5 MPa with a reasonable ionic conductivity.

Current Status of Heat Capacity Measurement Techniques for Ionic Liquids by DSC (DSC를 이용한 이온성 액체 열용량 측정 기술 현황)

  • Jo, Ye Lim;Kim, Ki-Sub;Park, Byung Heung
    • Journal of Institute of Convergence Technology
    • /
    • v.4 no.1
    • /
    • pp.5-8
    • /
    • 2014
  • Recently ionic liquids received much attention as novel materials capable of replacing traditional solvents. The applicability of the ionic liquids should be determined based on their physico-chemical properties. Heat capacity is one of the most important properties to be considered when a process is developed using the ionic liquids and currently DSC has been proved as an effective technique to measure the heat capacity. Micro DSCII can measure heat capacities of various liquids by both an isothermal step method and a scanning method. DSC Q100 and MDSC are able to measure heat capacities of several ionic liquids. For each ionic liquid linear regression of the heat capacity as a function of temperature has been performed to increase accuracy. To investigate the feasibility of ionic liquids as PCMs, their heat capacities have been measured by using Pysis I DSC. This paper briefly summarizes the present techniques of measuring heat capacities of ionic liquids by DSC.

Effect of Abnormal Grain Growth on Ionic Conductivity in LATP (LATP 내 비정상 입자성장이 이온 전도도에 미치는 영향)

  • Hyungik Choi;Yoonsoo Han
    • Journal of Powder Materials
    • /
    • v.31 no.1
    • /
    • pp.23-29
    • /
    • 2024
  • This study investigates the effect of the microstructure of Li1.3Al0.3Ti1.7(PO4)3 (LATP), a solid electrolyte, on its ionic conductivity. Solid electrolytes, a key component in electrochemical energy storage devices such as batteries, differ from traditional liquid electrolytes by utilizing solid-state ionic conductors. LATP, characterized by its NASICON structure, facilitates rapid lithium-ion movement and exhibits relatively high ionic conductivity, chemical stability, and good electrochemical compatibility. In this study, the microstructure and ionic conductivity of LATP specimens sintered at 850, 900, and 950℃ for various sintering times are analyzed. The results indicate that the changes in the microstructure due to sintering temperature and time significantly affect ionic conductivity. Notably, the specimens sintered at 900℃ for 30 min exhibit high ionic conductivity. This study presents a method to optimize the ionic conductivity of LATP. Additionally, it underscores the need for a deeper understanding of the Li-ion diffusion mechanism and quantitative microstructure analysis.

Knowledge State Analysis of Ionic Equation for Middle School Students (중학생들의 이온화식에 대한 지식상태분석)

  • Yoon, Heojeong;Lee, Yoonha;Kim, Youngshin
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.6
    • /
    • pp.499-507
    • /
    • 2015
  • The purpose of this study is to investigate middle school students’ understanding of ionic equation. Two hundreds and nineteen middle school students were participated in the study. After six class hours of learning ‘electrolyte and ion’ unit, instrument was implemented to evaluate students’ understanding of ionic process and ability to write ionic equation. We analyzed the influence of characteristics of ionic compounds on correct answer rate. In addition, knowledge state of students required for writing ionic equation was analyzed. The results were as follows: First, ionic compounds tested were categorized into six groups. The correct answer rate was different depending on the characteristics of each group. Second, knowledge state required for writing ionic equation was structured. Based on results some suggestion were made to develope effective learning strategy for understanding ionic equation.

Ionic Liquid Crystal Electrolytes based on Ether Functionalized Ionic Liquid for Lithium Batteries (리튬전지용 에테르가 기능화된 이온성 액체 기반 이온성 액정 전해질의 전기화학적 특성)

  • Kim, Il Jin;Kim, Ki Su;Lee, Jin Hong
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.305-309
    • /
    • 2020
  • In this study, a series of ionic liquids based electrolytes for lithium batteries were prepared by mixing the anion functionalized ionic liquid, [DMIm][MPEGP] (1,3-dimethylimidazolium (2-methoxy(2-ethoxy(2-ethoxy)))-ethylphosphite), with the lithium salt, LiTf2N (lithium bis(trifluoromethanesulfonyl)imide), and the concentration of lithium salt was varied between 0 and 3.0 molar ratio. We observed the ionic mixtures became opaque and spontaneously aggregated to form a thermotropic ionic liquid crystal. Extensive spectroscopic examinations of the ionic liquid crystals were carried out to investigate their self-organized structures and the ion transport behavior depending on the concentration of lithium salt. An increase in the ionic conductivity was observed for the ionic liquid crystals related to the ability to form ion diffusion pathways along the ordered structures, resulting in improved electrochemical performances of lithium batteries.

Application of Ionic Liquids in Biotechnology (생물공학에서 이온성 액체의 응용)

  • Lee Sang-Mok;Chang Woo-Jin;Koo Yoon-Mo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • Ionic liquids, composed of organic cations and either organic or inorganic anions remain liquid over a wide range of temperature. ionic liquids are a new group of solvents or extractants of great interest as a potential 'green solvent'. Ionic liquids are gaining wide recognition as novel solvents in many research fields, such as chemistry, chemical engineering, electrochemitry, etc. However, not much researches have been done related to biotechnology using ionic liquids, while a lot of researches have been performed in chemistry. The merits of ionic liquids in bioseparation technology are originated from some unique properties of ionic liquids, such as negligible vapor pressure, good thermal stability, controllable viscosity and miscibility with water and organic solvents. An appropriate selection of ionic liquid for bioprocesses requires basic knowledge on physicochemical properties of ionic liquids. This review gives a brief overview on the application of ionic liquids in biotechnology, including bioconversion and bioseparation.

Synthesis and Antiwear Properties of Ammonium Dithiocarbamate-based Ionic Liquid (I) (암모니움 디티오카바메이트계 이온성 액체의 합성 및 내마모성능 (I))

  • Baek, Seung-Yeob;Kim, Nam-Kyun;Shin, Jihoon;Chung, Keunwo;Kim, Young-Wun
    • Tribology and Lubricants
    • /
    • v.30 no.6
    • /
    • pp.323-329
    • /
    • 2014
  • The friction-reducing properties of lubricants containing ionic liquids based on ammonium dithiocarbamate are studied. The ionic liquids are produced through the following two steps: the synthesis of sodium alkyl dithiocarbamates via the substitution reaction of dialkylamine and carbon disulfide and their subsequent conversion into ammonium dithiocarbamate-based ionic liquids through an ion-exchange reaction with a quaternary alkyl ammonium halide salt. The structures of the ionic liquids are characterized by NMR spectroscopy and Fourier transform infrared spectroscopy. The isolated yields of the ionic liquids, which are viscous and pale yellow, are approximately 92%. The Brookfield viscosities and pour points of the ionic liquids are determined. Further, their wear resistances are measured through the four-ball wear test and the Schwingung Reibung Ver-schleiss (oscillation, friction, wear) test. The wear scar diameter of the lubricants containing 1 wt of the quaternary alkyl ammonium dithiocarbamate-based ionic liquids (0.475-0.631 mm) is significantly lower than that of the base oil (0.825 mm), proving that the ammonium dithiocarbamate-based ionic liquids have good friction-reducing characteristics. However, these friction-reducing characteristics fade significantly after long-term storage, owing to the degradation of the ionic liquids.

Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode (금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.