• Title/Summary/Keyword: ion transport

Search Result 466, Processing Time 0.026 seconds

Counterion Specific Conformational Transition and ion Selective Transport of a Poly(L-glutamic acid)/PVA Blend Membrane (Poly(L-glutamic acid)/PVA 블렌드막의 대이온 선택적인 구조전이와 이온투과 특성)

  • 허양일
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.802-809
    • /
    • 2000
  • Counterion-specific helix formation and ion-selective transport of alkali metal chlorides (LiCl, NaCl, KCl, CsCl) were investigated for a poly(L-glutamic acid)(PLGA)/poly (vinyl alcohol)(PVA) blend membrane immersed in aqueous ethanol. The counterion specificity for helix formation of PLG alkali metal salts in the membrane was Li>Na>K>Cs. This specificity is ascribed to a contact ion-pair formation between the PLG carboxyl anion and the bound counterion, which depends on the energy balance between the electrostatic interaction and the desolvation. In aqueous ethanol, an appreciable ion-selectivity was observed for the permeability coefficient, i.e. Li$^{+}{\cdot}$Cl$^{-}$) formation between counterion and coion, and the latter to a specific interaction of diffusing counterions with polymer charges.

  • PDF

Preparation and Characterization of Heterogeneous Anion Exchange Membrane for Recovery of Sulfate Ion from Waste Water (폐수 중 황산이온 회수를 위한 불균질 음이온교환막의 제조 및 특성)

  • Choi, Kuk-Jong;Choi, Jae-Hwan;Hwang, Eui-Hwan;Rhee, Young-Woo;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.3
    • /
    • pp.247-254
    • /
    • 2007
  • Heterogeneous anion exchange membranes were prepared by compression molding for the recovery of sulfate ion from waste water. The swelling ratio, transport number, and ion exchange capacity of the heterogeneous anion exchange membranes were increased and their electrical resistances were decreased as the amount of ion exchange resin content in the matrix was raised. The tensile strength of the heterogeneous anion exchange membrane was decreased with increasing the amount of ion exchange resin in the LLDPE. The tensile strength for the LDPE heterogeneous membrane containing 30 wt% anion exchange resin showed the highest value. The water content increased with increasing amount of ion exchange resin in the membrane. Moreover the highest transport number of the membrane was 0.86. The electrical resistance of LDPE matrix membrane with 50 wt% resin showed $46.5{\Omega}{\cdot}cm^2$. Current efficiency of electrodialysis for sulfate ion showed the highest value at the current density of $125 mA/cm^2$ in 0.5 mol/L sulfuric acids solution.

Electroconvective vortex on an Ion Exchange Membrane under Shear Flow (전단흐름 하에 이온교환막 위에서 발생하는 전기수력학적 와류)

  • Kwak, Rhokyun
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.61-69
    • /
    • 2018
  • Ion exchange membrane can transfer only cation or anion in electrically conductive fluids. Recent studies have revealed that such selective ion transport can initiate electroconvective instability, resulting vortical fluid motions on the membrane. This so-called electroconvective vortex (a.k.a. electroconvection (EC)) has been in the spotlight for enhancing an ion flux in electrochemical systems. However, EC under shear flow has not been investigated yet, although most related systems operate under pressure-driven flows. In this study, we present the direct visualization platform of EC under shear flow. On the transparent silicone rubber, microscale channels were fabricated between ion exchange membranes, while allowing microscopic visualization of fluid flow and ion concentration changes on the membranes. By using this platform, not only we visualize the existence of EC under shear flow, its unique characteristics are also identified: i) unidirectional vortex pattern, ii) its advection along the shear flow, and iii) shear-sheltering of EC vortices.

Preparation and Properties of PE Heterogeneous ion Exchange Membrane with Bead and Fibrous ion Exchanger (비드와 섬유이온교환체 고정 PE 불균질 이온교환막의 제조 및 특성)

  • 황택성;박명규;강경석
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.575-581
    • /
    • 2002
  • Heterogeneous ion exchange membranes were prepared by mixing polyethylene as matrix with bead and fibrous anionic ion exchangers at different mixing ratio. Generally, ion exchange capacities were increased with increasing the ratio of the fibrous ion exchanger content. The highest ion exchange capacity of the membrane was 1.86 meq/g at 30wt% IXF (ion exchange fiber) in the membrane. The water uptake, fixed ion concentration, and ion transport number of the membrane increased with increasing the content of the fibrous ion exchanger. However, the electrical resistivity of the membrane was decreased with increasing the content of the fibrous ion exchanger. The lowest electrical resistivity of 5$\Omega$/$\textrm{cm}^2$ was observed at 30 wt%of IXF.

Effect of measurement method and cracking on chloride transport in concrete

  • Zhang, Shiping;Dong, Xiang;Jiang, Jinyang
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.305-316
    • /
    • 2013
  • This paper aims to study the effect of measurement methods and cracking on chloride transport of concrete materials. Three kinds of measurement methods were carried out, including immersion test, rapid migration test and steady-state migration test. All of these measurements of chloride transport show that chloride ion diffusion coefficient decreased with the reduction of water to cement ratio. Results of the immersion test were less than that of rapid migration test and steady-state migration test. For the specimen of lower water to cement ratio, the external electrical field has little effect on chloride binding relatively. Compared with the results obtained by these different measurement methods, the lower water to cement ratio may cause smaller differences among these different methods. The external voltage can reduce chloride binding of concrete, and the higher electrical field made a strong impact on the chloride binding. Considering the effect of high voltage on the specimen, results indicate that results based on the steady-state migration test should be more reasonable. For cracked concrete, cracking can accelerate the chloride ion diffusion.

Tansport Rate of Chromium ion from Waste Water through the Liquid Surfactant Membrane Containing Carrier (운반체 함침 유화액막에 의한 폐수중 크롬(VI)의 이동속도)

  • Woo, In-Sung;Kim, Kyoung-Ho;Lee, Sang-Jin;Kang, An-Soo;Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 1988
  • The transport of chromium(VI) ion from waste water through the liquid surfactant membrane containing tri-n-octylamine as a carrier, was analyzed by a slab model and was investigated through experiments. For the experiment of membrane stability, concentrations of surfactant and liquid paraffin oil were analyzed. Extraction experiments were carried out to observe the effect of system variables, such as concentrations of carrier, and initial chromium(VI) ion in external aqueous phase at $25^{\circ}C$. It is concluded that the most stable formation of liquid membrane emulsion was obtained when surfactant concentration is above 3 wt.% and liquid paraffin oil concentration is 50 vol.%. The theoretical equation on the transport of chromium(VI) ion agreed well with the experimental results.

  • PDF

A Feasibility Study on the Cold Hollow Cathode Gas Ion Source for Multi-Aperture Focused Ion Beam System (다개구 이온빔 가공장치용 냉음극 방식의 가스 이온원의 가능성 평가에 관한 연구)

  • Choi, Sung-Chang;Kang, In-Cheol;Han, Jae-Kil;Kim, Tae-Gon;Min, Byung-Kwon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.383-388
    • /
    • 2011
  • The cold hollow cathode gas ion source is under development for multi aperture focused ion beam (FIB) system. In this paper, we describe the cold hollow cathode ion source design and the general ion source performance using Ar gas. The glow discharge characteristics and the ion beam current density at various operation conditions are investigated. This ion source can generate maximum ion beam current density of approximately 120 mA/$cm^2$ at ion beam potential of 10 kV. In order to effectively transport the energetic ions generated from the ion source to the multi-aperture focused ion beam(FIB) system, the einzel lens system for ion beam focusing is designed and evaluated. The ions ejected from the ion source can be forced to move near parallel to the beam axis by adjusting the potentials of the einzel lenses.

Numerical Analysis of Wintertime Air Pollution in East Asia Region Using Long-Range Transport Model

  • Jang, Eun-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 2000
  • In order to understand the wintertime intermittent characteristics of the trans-boundary air pollutant transport observed in East Asia, a numerical simulation of the long-range transport of pollutants was applied using an atmospheric transport model(STEM-II). The numerical simulation was carried out for the entire month of January 1997 and specific atmospheric aerosol (including sulfate, nitrate, and other ion compounds0 observation data were compared from four observation sites(Cheju Island, Kanghwa Island, Dazaifu, and Fukue Island). The observation data revealed that concentration peaks were intermittently observed at 3 to 4-day intervals plus the four observation sites exhibited a very similar spatial variation. The horizontal and spatial scale of the heavily polluted air masses was analyzed based on numerical results. The mechanism of the intermittent transport of air pollutants was clearly explained by a comparison of the observed data with the numerical output. It was found that the wind pattern variations associated with the synoptic scale pressure system changes play an extremely important role in the transport of pollutants in this region.

  • PDF

Transport Coefficients Across A Charged Mosaic Membrane III

  • Lee, Jungwoon;Minho Kang;Song, Myung-Kwan;Wongkang Yang;Lee, Jang-Woo
    • Korean Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.61-67
    • /
    • 2003
  • Various characteristics of ion transport properties of a charged mosaic membrane with a parallel array of positive and negative functional charges were investigated, From the analysis of the volume flux, it was found that the salt flux based on nonequilibrium thermodynamics, preferential salt transport across the charged mosaic membrane. Transport properties of the magnesium sulfate(MgSO$_4$) and sucrose across the charged mosaic membrane were estimated. As a result, metal salts transport depended largely on the charged states and molecular weight otherwise nonelectrolyte solution was rejected under all experimental conditions. On the other hand, the reflection coefficient s indicated the negative value that suggested preferential material transport and was independent of charged mosaic thickness.

Calix[6]arene Bearing Carboxylic Acid and Amide Groups in Polymeric CTA Membrane

  • Kim, Jong-Seung;Lee, Soo-Heon;Yu, Sang-Hyeok;Cho, Moon-Hwan;Kim, Dong-Won;Kwon, Seon-Gil;Lee, Eil-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.8
    • /
    • pp.1085-1088
    • /
    • 2002
  • Calix[6]arene having both carboxylic acid (1,3,5-) and carboxamide (2,4,6-) in an alternative way was synthesized. Transport rates of alkali and alkaline-earth metal ions were tested in bulk liquid membrane and polymer inclusion membrane. Ba2+ ion was found to give the highest transport rate among tested metal ions in both BLM and PIM systems. In PIM system, high durability (longer than 30 days) of the membrane was observed.